| INPUT SECTION |
| DATA Input |
EFM 8-16 Modulation SignalInput |
| Input Coupling |
AC (2 Hz / 1 kHz, selectable) |
| Measurement Voltage Range |
50 mV to 5 V p-p |
| Input Impedance |
1 MΩ / 50Ω, selectable |
| Slice Level Variable |
± 2.5 V |
| Auto (Asymmetry On) |
20 Hz / 1 kHz / 5 kHz / 10 kHz, selectable |
| Maximum Input Voltage |
± 5 V |
| Input Coupling |
AC |
| Measurable Voltage Range |
0.1 V to 2.5 V p-p |
| Input Impedance |
1 MΩ / 50Ω, selectable |
| Slice Level |
0 V (fixed) |
| Clock Delay |
≥ 10 ns for each polarity |
| Maximum Input Voltage |
± 5 V |
| Measurement Control (GATE IN) |
| Input Impedance |
10 kΩ |
| Input Signal Level |
TTL |
| Maximum Input Voltage |
-0.7 V to +5.7 V |
| JITTER MEASUREMENT SECTION |
| DVD |
Clock Frequency: 24.3 MHz to 59.4 MHz (Frequency is fixed to 27/54 MHz in one signal input mode,DATA to CLOCK mode) |
| CD |
x1, x2, x4, x8, x10, x12 speed |
| Measurement Mode |
| DVD |
Measurements for PERIOD, sum of all Tdata in PERIOD mode, PULSE WIDTH, sum of all T-data in PULSE WIDTH mode,DATA to CLOCK |
| CD |
Measurements for, PULSE WIDTH and sum of all T-PERIOD data |
| Units Displayed |
ns or % |
| Measurement Resolution |
0.15 ns |
| Display Resolution |
0.01 ns |
| Measurement Accuracy |
| Sigma Value |
± 4% ± 0.15 ns |
| Average Value |
± 1 ns |
| Measurement Item |
AVERAGE, max, min, σ, σ max, σ min, σ/T, σ/T max, σ/T min |
| Measurement Display |
value, bar graph, histogram,TIME DEVIATION, BOTH for separate display |
| Number of Samples |
1,000,000 max |
Control Function (ON/OFF, selectable) Inhibit Logic State Selection |
| ENABLE |
HIGH/LOW |
| Number of Gating Operations |
| GATE COUNT |
1 to 50 |
| Arming Polarity Selection |
| SLOPE |
RISE/FALL |
| Start Delay |
| START DLY |
1 to 9999 μs in 1 μs steps |
| Measurement Time Settings |
| LEN MODE |
SAMPLE/TIME (0.1 ms to 99.9 ms in 0.1 ms steps) |
| Number of Gating Operations |
| GATE COUNT |
0 to 50 |
| LEVEL MEASUREMENT SECTION |
| Measurement Method |
Peak to peak value of DATA signal |
| Measurable Voltage Range |
50 mV to 5 V p-p (0.5 to 9.999 V p-p in 10:1 probe conversion mode) |
| Display Digit |
4 (3 digits after decimal point) |
| Measurement Resolution |
1 mV min |
| Measurement Accuracy |
± 5% |
| Display |
Item name in level measurement mode
1:1 mode ---- LVL 10:1 mode ----*LVL |
| CLOCK FREQUENCY MEASUREMENT SECTION (DVD,DATA to CLOCK mode only) |
| Measurement Range |
24.3 MHz to 59.4 MHz |
| Measurement Accuracy |
± 0.5% |
CLOCK REGENERATOR (DVD,DATA to CLOCK mode only) Regenerates reference clock signal from |
| DATA (RF) signal input Applicable Speed |
DVD x1 speed (27 MHz ± 10%) DVD x2 speed (54 MHz ± 10%) |
OUTPUT SECTION Monitor Output (Probe CAL) DATA (Used for DATA signal monitoring and probe calibration) |
| Bandwidth |
50 MHz, ≤ -3 dB |
| Output Impedance |
50Ω |
| CLOCK (Used for CLOCK signal monitoring and probe calibration) |
| Bandwidth |
60 MHz, ≤ -3 dB |
| Output Impedance |
50Ω |
EQUALIZER OUT Used for equalized RF signal monitoring |
| Output Impedance |
50Ω |
| DC OUT Output Accuracy |
± 2% |
GATE MONITOR Used for arming and inhibit control signal monitoring |
| Output Level |
TTL level |
| Output Impedance |
1 kΩ |
| MEMORY CARD |
| Interface |
Conforms to PC CARD ATA standards |
| ENVIRONMENTAL CONDITIONS |
| Operating Temperature |
0 to 40° C, 30 to 85% RH (without condensation) |
| Spec Guaranteed Temperature |
10 to 30° C, 30 to 85% RH (without condensation) |
| Storage Temperature |
0 to 50°C, 0 to 90% RH (without condensation) |
| Operating Environment |
| Altitude |
Up to 2000 m |
| Overvoltage Category |
II |
| Pollution Degree |
2 |
| POWER REQUIREMENTS |
90 to 250 V ac universal, 50/60 Hz Max. 35 W, 50 VA max. |
| PHYSICAL |
| Size (W x H x D) |
83/8 x 51/4 x 113/4 in., 213 x 132 x 300 mm |
| Weight |
11 lbs., 5 kg |
| SUPPLIED ACCESSORIES |
Instruction Manual, Spare Fuse, Power Cord |
| AVAILABLE OPTIONS |
OP71 - CD-R/RW Measurement, OP72 - GPIB, OP74 - Fixed Equalizer, OP75 - Variable Equalizer, OP76 - Variable Equalizer |