| Electrical Characteristics |
| Current Ranges |
60 A and 600 A ACRMS or DC |
| Measuring Range |
± 85 A and ± 850 A |
| Output Sensitivity |
10 mV/A (60 A) 1 mV/A (600A) |
| Accuracy (at +25°C) |
(60A Range) ± 1% of reading ± 0.1 A (600A Range) ± 1% of reading ± 0.5 A |
| Resolution |
± 100mA (60 A and 600 A) |
| Load Impedance |
> 10kOhms and ≤ 100 pF |
| Conductor Position Sensitivity |
± 1% relative to centre reading |
| Frequency Range…(small signal) |
DC to 20 kHz (-3 dB) |
| Phase Shift Below 1 kHz |
< 2 degrees |
| Temperature Coefficient |
± 0.1% of reading / °C |
| Power Supply |
9 V Alkaline, MN1604/PP3 50hours, low battery indicator |
| Auto Switch Off |
30 minutes typical |
| Working Voltage (see Safety Standards Section) |
600 V ACRMS or DC |
| General Characteristics |
| Maximum Conductor Size |
35 mm diameter |
| Output Connection |
Safety BNC connector |
| Output Zero |
Auto zero via push button |
| Cable Length |
2 meters |
| Operating Temperature Range |
-10 to +60 °C |
| Storage Temperature Range.(with battery removed) |
-20 to +85 °C |
| Operating Humidity |
15% to 85% (non condensing) |
| Weight |
480 g |