| Electrical Characteristics |
| Current Range |
20 A ACRMS or DC |
| Measuring Range |
± 30 A |
| Output Sensitivity |
100 mV / A |
| Accuracy (at +25°C) |
± 1% of reading ± 2 mA |
| Resolution |
± 1 mA |
| Load Impedance |
> 100 kOhms |
| Conductor Position Sensitivity |
± 1% relative to centre reading |
| Frequency Range |
DC to 100 kHz (- 0.5 dB) |
| Phase Shift below 1 kHz |
< 2 degrees |
| Temperature Coefficient |
± 0.01% of reading / °C |
| Power Supply |
9 V Alkaline, MN1604/PP3 30 Hours, low battery indicator |
| Working Voltage (see Safety Standards section) |
300 V ACRMS or DC |
| General Characteristics |
| Maximum Conductor Size |
19 mm diameter |
| Output Connection |
safety BNC connector |
| Output Zero |
Manual adjust via thumbwheel |
| Cable Length |
2 meters |
| Operating Temperature Range |
0 to +50 °C |
| Storage Temperature Range (with battery removed) |
-20 to +85 °C |
| Operating Humidity |
15% to 85% (non condensing) |
| Weight |
250 g |