LEM PR200ACI Multimeter AC only Current Probe

Click image to enlarge
LEM PR200ACI
|
|
Features:
- Measuring range: 0.5 to 300 A RMS
- Maximum conductor size: 15 mm
- Output connection via 4 mm safety sockets
- 40 Hz to 10 kHz frequency range
Advantages:
- Smallest probe in the market
- Unique safety features for short circuit protection - SIAC
- Small jaw size for restricted access
- % accuracy of reading
|
Description
|
The PR 200ACI current probe has been
designed for use with multimeters, recorders,
power analysers, safety testers etc. for
accurate non intrusive measurement of AC
current. Using the latest transformer technology,
the PR 200ACI can measure currents from 0.5A
to 300A over a frequency range of 40Hz to
10kHz.
|
Models, Options, & Accessories
| Model |
Description |
List Price |
Sale Price |
| PR200ACI |
60.95.44.016.0, PR 200A AC 15MM 1MA/A O/P DMM - Discontinued - no replacement |
Specifications
| Electrical Characteristics |
| Current Range |
200 A ACRMS |
| Measuring Range |
0.5 A to 300 ARMS |
| Output Sensitivity |
1 mA / A |
| Load Impedance |
£ 10 O |
| Conductor Position Sensitivity |
< 0.5% @ 50/60Hz |
| Error due to adjacent conducto |
£ 15 mA / A @ 50Hz |
| Phase Shift at 2 kHz @ 10 |
± 1 degree |
| Frequency Range |
40 Hz to 10 kHz (- 3 dB) |
| Temperature Coefficient |
0.015% / °C |
| Working Voltage (see Safety Standards section) |
600 V ACRMS or DC |
| General Characteristics |
| Maximum Conductor Size |
15 mm diameter, bus bar 15 x 17mm |
| Output Connection |
4 mm safety sockets |
| Operating Temperature Range |
-10 to +55 °C |
| Storage Temperature Range |
-20 to +70 °C |
| Operating Humidity |
15% to 85% (non condensing) |
| Weigh |
175 g |
|