company logo LEM LH2040 AC/DC Clamp-on Multimeter
     Search: HACKER SAFE certified sites prevent over 99.9% of hacker crime.  
 
 
 




LEM LH2040 AC/DC Clamp-on Multimeter



LEM LH2040
Click image to enlarge

 LEM LH2040

Features:
  • 2000A
  • AC and DC Amps, Volts, Ohms, Diode and Continuity Test
  • Large jaw capacity takes 50mm or 2 x 30mm cables
  • True RMS measurement of complex waveforms and analysis of AC and DC current components
  • Auto-ranging and Auto-zeroing
  • Excellent accuracy, even for distorted or nonsinusoidal A and V
  • Display-Hold and Max-Hold (surge) modes for convenience in use
  • Analogue outputs for recorder, logger or oscilloscope
  • Conformance to IEC1010 and EMC standards
Advantages:
  • AC, DC and AC + DC True RMS current measurement



  Description

High Accuracy
Advanced jaw design means that 40-series accuracy is little affected by external magnetic fields or off-centre conductor positioning. Utilisation of Hall effect technology ensures a broad flat frequency response resulting in optimum accuracy even when harmonics are present.

IEC 1010 and EMC Conformance
IEC 1010 safety features including a tactile barrier and special jaw design provide the user with confidence when making measurements in hazardous voltage areas.

Conformance to EMC standards ensures high reliability through reduced susceptibility to electromagnetic interference. True RMS measurement
By using True RMS measurement techniques the 40-series instruments avoid errors (up to 50%) which can occur when nonsinusoidal waveforms created by today’s complex loads are measured using traditional average-reading techniques. True RMS measurements are available for AC, DC (A, V) and AC+DC (A).



  Models, Options, & Accessories


Model Description List Price Sale Price
LH2040 60.56.69.000.0, AC/DC TRMS 400/2000A CLAMP DMM - Discontinued - no replacement
LH240 60.56.45.000.0, AC/DC TRMS 40/200A CLAMP - Discontinued - no replacement
LH1040 60.56.60.002.0, AC/DC TRMS 400/1000A CLAMP - Discontinued - no replacement



  Specifications

NON-INVASIVE CURRENT MEASUREMENT
Ranges (auto-ranging) 400A, 2,000A
Method DC or AC True RMS, or DC only
Resolution 100mA (400A range)
1A (2,000A range)
Accuracy ± 1.3 % of reading ± 3 digits (1)
Crest Factor 6 maximum for True RMS measurements
Maximum measurable load 2,000A DC or AC peak
Maximum permissible overload 10,000 Amps
ANALOGUE OUTPUT
Switchable Instantaneous or RMS (100 ms) output 0.5mV/A
Analogue output accuracy ± 1.3% of reading ± 1mV
Voltage Measurement
Methods of measurement AC True RMS or DC
Ranges (auto-ranging) 400V, 600V
Maximum overload 1,000V
Accuracy ±1% of reading ± 3 digits (1)
Resolution 100mV (400V range) 1V (600V range)
Crest Factor 6 for V < 1,000 V peak
Input impedance 1 MΩ
Resistance, Continuity and Diode Testing
Ω ranges (auto-ranging) 400 Ω, 4 kΩ
Ω resolution 0.1 Ω (400 Ω range)
1 Ω (4 kΩ range)
Ω accuracy ± 1% of reading ± 3 digits (1)
Continuity sounder Toggled on & off by )))) button;
(Ω range only) Sounds when resistance < 50Ω
Input protection, Ω & diode test To 600 V, DC or sine wave RMS
Diode-test 3.2V max. open Reads forward-biased diode
Circuit, 0.3mA short-circuit Voltage to 2,000 mV
Diode-test accuracy ± 1 % of reading ± 2 digits
Frequency Response (Measurements and Analogue Output)
AC only True RMS V & A 15Hz to 1kHz (3,4)
DC True RMS A DC + 15Hz to 1KHz (3,4) DC V and A DC only
Display
Size and type 4000-count LCD
12mm / 0.5-inch characters
Status indication Low Battery, Data Hold, Pk (MAX Hold), AC, DC, Diode Test, Ω, )))) (Continuity)
Refresh rate 3 times per second
Power Supply
Battery type 9 V Alkaline: MN1604, PP3
IEC 6LR61 or equivalent
Battery life Typically 40 hours
Mechanical Data
Dimensions (H x W x D) 251 x 98 x 52 mm
9.88 x 3.86 x 2.05 inches
Weight 500gm / 1.1 lbs
Jaw Capacity 1 x 50 mm/ 2.0-inch ∅ cables or 2 x 30mm/ 1.2-inch ∅ cables
Jaw Opening 55mm/ 2.2 inches
Environmental Data
Operating Temperature 0 °C to 50 °C (32 °F to 122 °F)
Temperature Coefficient ± 0.1% of reading per °C
(Current) ± 0.06% of reading per °F
Storage Temperature -20° to 60° (-4 °F to 140 °F)
Safety All models comply with IEC1010-1, 600V working, Installation category III, Pollution degree 2.
Maximum Safe Voltages Current measurement 600V AC RMS or DC between (bare conductors) uninsulated conductor & ground
Voltage measurement 600V AC RMS or DC between input terminals or between live terminal & local ground.




 

Welcome | Companies | Search by Type | How To Order | Leasing | About Us | Careers
  Tequipment.NET
205 Westwood Ave
Long Branch, NJ 07740
BBBOnline Reliability Seal, Click for confirmation page. Tequipment.NET
Phone: 1-877-571-7901 / 732-222-7077
Fax: (732) 222-7088
E-mail: salesteam@Tequipment.NET
 



Live chat by BoldChat
Need help? We have a staff
of more than 30 people to help you.
Let us show you why over 100,000
customers choose Tequipment.NET