Features:
  • Max. Input Voltage: 200V
  • Max. Input Power: 150W
  • Max. Input Current: 30A
  • High-speed response
    SW(switching) operation is available in the CC or CR discharging mode. It features the maximum response of 10µs (in the CC discharging mode).
  • 100 sequence memory
    Storing on panel in the memory facilitates easy sequence operation.
  • External control
    Every model allows analog control according to external voltage (0 to 10V) and external resistance (0 to 10kOhm).
  • GP-IB interface
    Every model has the general purpose interface bus GP-IB as the standard feature.
  • Master slave parallel operation
    A maximum of five units can be connected in the parallel master slave operation mode.
  • Various protective functions
    Three protective functions are available: UVP (Under Voltage Protection), OCP (Over Current Protection) and OPP (Over Power Protection). Six alarm functions are available: RCP (Reverse Connection Protection) alarm, OPP (Over Power Protection) alarm, OVP (Over Voltage Protection) alarm, OCP (Over Current Protection alarm, OHP (Over Heat Protection) alarm and UVP (Under Voltage Protection) alarm.
  • Software start function
    The current rise time of the load side can be adjusted according to the rise time of the output voltage, when test the rise time of switching power supply.



  Description

The PEL series are DC electronic loads which are ideal in aging‚characteristic analysis and product life testing applications including switching power supplies and batteries. A sophisticated program function enables high speed response and load characteristic simulation. A minimum operating voltage down to 0V is a standard feature of the V1 versions. The maximum application voltage is 200V or 500V, the input power is 150, 300, 600 or 1000W. The input current is 30A for 150W, 60A for 300W, 120A for 600W or 200A for 1000W.




  Models, Options, & Accessories


Model Description List Price Sale Price
PEL601-201V1 600W /120A / 200V, Minimum 0 Volt Operating Model $5718.00
$5146.20 



  Specifications

Model PEL151-501 PEL301-501 PEL601-501 PEL102-501
Input Power 0 to 150 W 0 to 300 W 0 to 600 W 0 to 1000 W
Input Voltage Range CR Mode:0 to 500V, CC/CP/CV Mode:5 to 500V
Input Current Range(Front/Rear Terminal) 0 to 7.5 A / 0 to 7.5 A 0 to 15 A / 0 to 15 A 0 to 30 A / 0 to 30 A 0 to 30 A / 0 to 50 A
Constant Current Mode Range/Resolution H Range: 7.5 A: 0 to 7.5 A / 1 mA / 150 W max
L Range: 75 mA: 0 to 75 mA / 2.5 µA / 15 W max
H Range: 15 A: 0 to 15 A / 2 mA / 300 W max
L Range: 150 mA: 0 to 150 mA / 5 µA / 3 W max
H Range: 30 A: 0 to 30 A / 4 mA / 600 W max
L Range: 300 mA: 0 to 300 mA / 10 µA / 6 W max
H Range: 50 A: 0 to 50 A / 5 mA / 1000 W max
L Range: 500 mA: 0 to 500 mA / 20 µA / 10 W max
Accuracy ±0.2% of SET ±0.3% of FS (0 to 40°C)
Ripple Noise (1MHz) H Range 3 mA rms / L Range 0.5 mA rms H Range: 5 mA rms / L Range: 0.5 mA rms H Range: 5 mA rms / L Range: 0.5 mA rms H Range: 10 mA rms / L Range: 1 mA rms
Stability ±0.1% of FS (typ) 
Constant Resistance Mode Range H Range: OPEN, 20k Ohm to 0.6667m Ohm
L Range: OPEN, 2M Ohm to 66.67 Ohm
H Range: OPEN, 10k Ohm to 0.3333 Ohm
L Range: OPEN, 1 M Ohm to 33.33 Ohm
H Range: OPEN, 5 k Ohm to 166.67 m Ohm
L Range: OPEN, 500 k Ohm to 16.667 Ohm
H Range: OPEN, 3.3333k Ohm to 111.11 m Ohm
L Range: OPEN, 333 k Ohm to 11.111 Ohm
Resolution H Range: 50 µs / L Range:0.5 µs H Range: 100 µs / L Range: 1 µs H Range: 200 µs / L Range: 2 µs H Range: 300 µs / L Range: 3 µs
Accuracy (23°C ±5°C) H Range: ±0.5% of SET ±37.5 mA Vin/Rin
L Range: ±0.5% of SET ±0.375 mA Vin/Rin
H Range: ±0.5% of SET ±75 mA Vin/Rin
L Range: ±0.5% of SET ±0.75 mA Vin/Rin
H Range: ±0.5% of SET ±0.25 A Vin/Rin
L Range: ±0.5% of SET ±1.5 mA Vin/Rin
H Range: ±0.5% of SET ±0.25 A Vin/Rin
L Range: ±0.5% of SET ±2.5 mA Vin/Rin
Ripple Noise (1MHz) H Range: 3 mA rms / L Range: 0.5 mA rms H Range: 5 mA rms / L Range: 0.5 mA rms H Range: 5 mA rms / L Range: 0.5 mA rms H Range: 10 mA rms / L Range: 1 mA rms
Temperature Factor 1000PPM/°C (Vin=20 V)
Constant Voltage Mode 50V Range/500V Range 5 to 50 V/40 to 500 V (CC CV Mode, CR CV Mode)
Accuracy/Resolution/Minimum Operating Current ±0.1% of SET ±0.1% of FS (0 to 40°C) / 50 V Range: 1 mV, 500 V Range: 10m V / 1% of Constant Current
Constant Power Mode Operating Range/Resolution H Range: 1.5 to 150 W / 5 m W
L Range: 0.03 to 1.5 W / 50 µW
H Range: 3 to 300 W / 10 mW
L Range: 0.06 to 3 W / 100 µW
H Range: 6 to 600 W / 20m W
L Range: 0.12 to 6 W / 200 µW
H Range: 10 to 1000 W / 25 mW
L Range: 0.2 to 10 W / 250 µW
Accuracy (23°C ±5°C) ±0.4% SET ±1.6% FS ±Vin x Vin / Rin (Vin x Vin / Rin for Current L Range) (TEMP factor: 1000PPM/ °C (Vin=20 V))
Ripple Noise (1MHz) H Range : 3 mA rms / L Range : 0.5 mA rms H Range: 5 mA rms / L Range: 0.5 mA rms H Range : 5 mA rms / L Range : 0.5 mA rms H Range : 10 mA rms / L Range : 1 mA rms
Short Mode Setting Current Value 0.075/7.5 A 0.15/15 A 0.3/30 A 0.5/50 A
SW Mode (Preset A,B) Frequency/Accuracy 1 Hz to 10kHz / ±1.5% SET
DUTY/Setting Accuracy/Resolution 5% to 95% / ±1.5% of SET / 1% STEP
Through Rate Tr/Tf  Operating Mode CC, CR
Setting Range CC:10 / 20 / 50 / 100 / 200 / 500 / 1000 / 2000µs, CR:OFF / 200 / 500 / 1000 / 2000µs
Setting Accuracy H : 10, 20µs :-5µ s : ±10µs, L:10, 20µ s : ±10µs, H : 50 to 2000µs : ±20 %, L : 50 to 2000µs : ±30 %
Soft Start Operating Mode CC
Setting Range/Accuracy 0.1 / 1 / 2 / 5 / 10 / 20 / 50 / 100ms / ±30 % of set 100µs
Remote Sensing 2.5 V par One Way
External Control Voltage 0 to 10 V (Offset gain Adjustable at Rear Panel. ) It takes approx. 1 Second for Settings at CR Mode
Resistance 0 to 10k Ohm (It takes approx. 1 Second for Settings)
Others LOAD ON/OFF, EXT SW 
Series/Parallel (Master/Slave Operation) Connecting Capability Maximum 4 of Slave Units plus 1 Master Unit
Added Current Display Total Value of Slave Unit(s) and Master Unit are Displayed at Master Unit Display. Over Write : 2 times/Sec
Resolution (L Range/H Range) 2 x N (mA) N: Parallel Unit Numbers.
Current Monitor Out Linearity ±1% FS
DC Current Measurement Range/ (Resolution) 0.075 / 7.5 A / (0.02 mA/2 mA) 0.15/15 A/(0.02 mA/2 mA) 0.3 / 30 A / (0.02 mA/2 mA) 0.5/50 A / (0.02 mA/2 mA)
Accuracy/Repeat ±0.2% of rdg ±0.3% of FS (0 to 40°C) / 2 Times/Sec
DC Voltage Measurement Range/Resolution 0 to 50 V/1 mV, 40 to 525 V/10 mV (Auto Range, Hysteresis at 40/50 V)
Accuracy/Repeat/Temperature Factor 50 V Range : ±0.03 % of rdg ±0.06% of FS, 500 V Range : ±0.03% of rdg ±0.03% of FS (18 to 28 °C) / 2 Times/Sec /
±0.003 % of rdg ±0.003 % of FS/ °C
Power Measurement Range/Resolution 1.5, 150 W / 1, 100 mW (Voltage x Current) 3, 300 W / 1, 100 mW (Voltage x Current) 6, 600 W / 1, 100 mW (Voltage x Current) 10, 1000 W / 1, 100 mW (Voltage x Current)
UVP (Under Voltage ) Range/Resolution OFF, -0.5 to 50 V/100 mV
OPP (Over Power) Range/Resolution H Range: 15 to 165W/1W / L Range: 0.15 to 1.65W/10mW H Range: 30 to 330W/2W / L Range: 0.3 to 3.3W/20mW H Range: 60 to 660 W/4 W / L Range: 0.6 to 6.6 W/40 mW H Range: 100 to 1100 W/5 W, L Range: 1 to 11 W/50 mW
OCP (Over Current) Setting Range/Resolution H Range: 0.75 to 8.25 A/37.5 mA
L Range: 7.5 to 82.5 A/0.375 mA
H Range: 1.5 to 16.5 A/75 mA
L Range: 15 to 165 mA/0.75 mA
H Range: 3 to 33 A/150 mA
L Range: 0.03 to 0.33 A/1.5 mA
H Range: 5 to 55 A/250 mA
L Range: 0.05 to 0.55 A/2.5 mA
Protection Over Voltage Cut Load Off about 575 V
Over Current, Over Power Automatic Resume After 3 Sec of Load Off
Reversed Connection Terminate by Parasitic FET
Over Heating Cut Load Off at 110 °C at Inside Heat Sink
Sequence Memory Step/Time/Resolution 100 / 50 µs to 99h59m59.99995 s, PAUSE, PASS / 50 µs, Cycle: 1 to 255
Items Discharge Mode Pre-set A, B and C Value, Pre-set A, B and C Switch Selection, Discharge Mode, SHORT Mode 
ON/OFF, LOAD ON/OFF, UVP Setting value, OCP Setting value, OPP Setting Value, Soft Start Setting Value, Tr/Tf 
Setting value, SW Frequency, SW DUTY, CV RANGE, Current RANGE, External Control Mode (PASS at Auto Sequence Mode)
Environmental Request Temperature/Humidity 0 to 40°C / 20 to 85 %RH
Power Source AC90 to 132 V / AC180 to 250V, 48 to 63 Hz
Power Consumption Less than 120 VA Less Than 130VA Less than 147VA Less Than 169VA
Isolation Primary to Body : 1500VAC 1 Minute, Primary to Secondary : 2300VAC 1 Minute
Isolation Resistance Primary to Body, Primary to Secondary : 500VDC More Than 10M Ohm, Secondary to Body : 500 VDC More Than 5M Ohm
Cooling Method Cooling Fan
Dimensions (Maximum) W x H x D: 210 (210) x 124 (141) x 405 (538) (mm) W x H x D: 421.5 (421.5) x 124 (132.5) x 405 (538) (mm)
Weight Approx. 6 kg Approx. 7 kg Approx. 11 kg Approx. 13 kg



   
  Welcome | Companies | Search by Type | How To Order | Leasing | About Us  
  Tequipment.NET
205 Westwood Ave
Long Branch, NJ 07740
For our Electronic Whiteboard division visit www.touchboards.com
BBBOnline Reliability Seal. Tequipment.NET
Phone: 1-877-742-TEST (8378) / 732-222-7077
Fax: (732) 222-7088
E-mail: salesteam@Tequipment.NET