Our agents are available:
9:00 AM - 6:00 PM EST
Kenwood PEL151-201
DC Electronic Load
   Search: HACKER SAFE certified sites prevent over 99.9% of hacker crime.
   

   
   




Kenwood PEL151-201
DC Electronic Load



Kenwood PEL151-201
Click image to enlarge

 Kenwood PEL151-201
Features:
  • Max. Input Voltage: 200V
  • Max. Input Power: 150W
  • Max. Input Current: 30A
  • High-speed response
    SW(switching) operation is available in the CC or CR discharging mode. It features the maximum response of 10µs (in the CC discharging mode).
  • 100 sequence memory
    Storing on panel in the memory facilitates easy sequence operation.
  • External control
    Every model allows analog control according to external voltage (0 to 10V) and external resistance (0 to 10kOhm).
  • GP-IB interface
    Every model has the general purpose interface bus GP-IB as the standard feature.
  • Master slave parallel operation
    A maximum of five units can be connected in the parallel master slave operation mode.
  • Various protective functions
    Three protective functions are available: UVP (Under Voltage Protection), OCP (Over Current Protection) and OPP (Over Power Protection). Six alarm functions are available: RCP (Reverse Connection Protection) alarm, OPP (Over Power Protection) alarm, OVP (Over Voltage Protection) alarm, OCP (Over Current Protection alarm, OHP (Over Heat Protection) alarm and UVP (Under Voltage Protection) alarm.
  • Software start function
    The current rise time of the load side can be adjusted according to the rise time of the output voltage, when test the rise time of switching power supply.



  Description

The PEL series are DC electronic loads which are ideal in aging‚characteristic analysis and product life testing applications including switching power supplies and batteries. A sophisticated program function enables high speed response and load characteristic simulation. A minimum operating voltage down to 0V is a standard feature of the V1 versions. The maximum application voltage is 200V or 500V, the input power is 150, 300, 600 or 1000W. The input current is 30A for 150W, 60A for 300W, 120A for 600W or 200A for 1000W.




  Models, Options, & Accessories


Model Description List Price Sale Price
PEL151-201 150W / 30A / 200V $3078.00
$2770.20 



  Specifications

Input Power 0 to 150 W
Input Voltage Range CR Mode:0 to 200V, CC/CP/CV Mode:1.5 to 200V
Input Current Range(Front/Rear Terminal) 0 to 30A / 0 to 30A
Constant Current Mode Range/Resolution H Range: 30A: 0 to 30A / 1mA 150W max
L Range: 0.3A: 0 to 0.3A / 10μA 1.5W max
Accuracy ±0.2% of SET ±0.3% of FS (0 to 40°C)
Ripple Noise (1MHz) H Range 10mA rms / L Range 1mA rms
Stability ±0.1% of FS (typ)
Constant Resistance Mode Range H Range: OPEN, 1.5kΩ to 50mΩ
L Range: OPEN, 150kΩ to 5Ω
Resolution H Range: 0.66ms / L Range:6.6μs
Accuracy (23°C ±5°C) H Range: ±0.5% of SET ±0.15A Vin/Rin
L Range: ±0.5% of SET ±1.5mA Vin/Rin
Ripple Noise (1MHz) H Range: 10mA rms / L Range: 1mA rms
Temperature Factor 1000PPM/°C (Vin=5V)
Constant Voltage Mode 20V Range/200V Range 1.5 to 20V/15 to 200V (CC CV Mode, CR CV Mode)
Accuracy/ Resolution/ Minimum Operating Current ±0.1% of SET ±0.1% of FS (0 to 40°C) / 20V Range: 1mV, 200V Range: 10mV / 1% of Constant Current
Constant Power Mode Operating Range/Resolution H Range: 3 to 150W / 5mW
L Range: 0.03 to 1.5W / 50μW
Accuracy (23°C ±5°C) ±0.4% SET ±1.6%FS ±Vin x Vin / Rin (Vin x Vin / Rin for Current L Range) (TEMP factor: 1000PPM/°C (Vin=5V))
Ripple Noise (1MHz) H Range: 10mA rms / L Range : 1mA rms
Short Mode Setting Current Value 0.3/30A (V1 model CC0V: 18A)
SW Mode (Preset A,B) Frequency/Accuracy 1Hz to 10kHz / ±1.5% SET
DUTY/ Setting Accuracy/ Resolution 5% to 95% / ±1.5% SET / 1% STEP
Through Rate Tr/Tf Operating Mode CC, CR
Setting Range CC:10 / 20 / 50 / 100 / 200 / 500 / 1000 / 2000μs, CR:OFF / 200 / 500 / 1000 / 2000μs
Setting Accuracy H: 10, 20μs :-5μs : ±10μs, L: 10, 20μs : ±10μs, H: 50 to 2000μs : ±20 %, L: 50 to 2000μs : ±30%
Soft Start Operating Mode CC
Setting Range/Accuracy 0.1 / 1 / 2 / 5 / 10 / 20 / 50 / 100ms / ±30 % of set 100μs
Remote Sensing   2.5 V par One Way
External Control Voltage 0 to 10V (Offset gain Adjustable at Rear Panel. ) It takes approx. 1 Second for Settings at CR Mode
Resistance 0 to 10kΩ(It takes approx. 1 Second for Settings)
Others LOAD ON/OFF, EXT SW
Series/Parallel(Master/Slave Operation) Connecting Capability Maximum 4 of Slave Units plus 1 Master Unit
Added Current Display Total Value of Slave Unit(s) and Master Unit are Displayed at Master Unit Display. Over Write : 2 times/Sec
Resolution (L Range/H Range) 0.1 x N / 10 x N (mA) N: Parallel Unit Numbers.
Current Monitor Out Linearity ±1% FS
DC Current Measurement Range/ (Resolution) 0.3 / 30 A / (0.1/10 mA)
Accuracy/Repeat ±0.2% of rdg ±0.3% of FS (0 to 40°C) / 2 Times/Sec
DC Voltage Measurement Range/Resolution 0 to 20V / 1mV, 20 to 210V / 10mV (Auto Range, Hysteresis at 18 /20V)
Accuracy/Repeat/Temperature Factor 20V Range: ±0.03% of rdg ±0.06% of FS, 200V Range: ±0.03% of rdg ±0.03% of FS (18 to 28°C) / 2 Times/Sec / ±0.003% of rdg ±0.003% of FS/°C
Power Measurement Range/Resolution 1.5, 150W / 1, 100mW (Voltage x Current)
UVP (Under Voltage) Range/Resolution OFF, -0.5 to 20 V/20mV
OPP (Over Power) Range/Resolution H Range: 15 to 165W/1W / L Range: 0.15 to 1.65W/10mW
OCP (Over Current) Setting Range/Resolution H Range: 3 to 33A/150mA / L Range: 0.03 to 0.33A/1.5mA
Protection Over Voltage Cut Load Off about 230V
Over Current, Over Power Automatic Resume After 3 Sec of Load Off
Reversed Connection Terminate by Parasitic FET
Over Heating Cut Load Off at 110°C at Inside Heat Sink
Sequence Memory Step/Time/Resolution 100 / 50μs to 99h59m59.99995s, PAUSE, PASS / 50μs, Cycle: 1 to 255
Items Discharge Mode Pre-set A, B and C Value, Pre-set A, B and C Switch Selection, Discharge Mode, SHORT Mode
ON/OFF, LOAD ON/OFF, UVP Setting value, OCP Setting value, OPP Setting Value, Soft Start Setting Value, Tr/Tf
Setting value, SW Frequency, SW DUTY, CV RANGE, Current RANGE, External Control Mode (PASS at Auto Sequence Mode)
Environmental Request Temperature/Humidity 0 to 40°C / 20 to 85 %RH
Power Source AC90 to 132V / AC180 to 250V, 48 to 63 Hz
Power Consumption Less than 75VA
Isolation Primary to Body: 1500VAC 1 Minute, Primary to Secondary: 2300VAC 1 Minute
Isolation Resistance Primary to Body, Primary to Secondary: 500 VDC More Than 10MΩ, Secondary to Body: 250VDC More Than 5MΩ
Cooling Method Cooling Fan
Dimensions (Maximum) WxHxD: 210 (210) x 124 (141) x 405 (538) (mm)
Weight Approx. 6 kg



   
  Welcome | Companies | Search by Type | How To Order | Leasing | About Us  
  Tequipment.NET
205 Westwood Ave
Long Branch, NJ 07740
For our Electronic Whiteboard division visit www.touchboards.com
BBBOnline Reliability Seal. Tequipment.NET
Phone: 1-877-742-TEST (8378) / 732-222-7077
Fax: (732) 222-7088
E-mail: salesteam@Tequipment.NET