Features
  • Complies with Power Supply Harmonics Current Regulation, and a Power Factor of 95% (typical)
  • Satisfying CE Mark Certification Requirements
  • Series/Parallel Operation
  • Voltage/Current Simultaneous Digital Display
  • Voltage/Current Preset (3 points)
  • Single-Dial Control Design
  • Key Lock Function
  • Compact, Lightweight Design
  • Various Protection Functions
  • Board-Type Options for External Control
  • Worldwide AC Voltage Input Design




  Description

The PDS Series are CE-certified Regulated DC Power Supply units which comply with Power Supply Harmonics Current Regulations IEC1000-3-2‚ and a power factor of 95% (typical) is cleared. These models feature high reliability and various types of protection‚ and can be used as a power supply for reliability tests‚ endurance tests‚ aging and other electronics parts tests.

By employing a unique switching and dropper circuit systems‚ the output noise is maintained at a minimized level.The input AC voltage is possible from 90 to 246 volts without any modification. Furthermore‚ these models are designed in a smaller size and a lighter weight compared to conventional models.

Complies with Power Supply Harmonics Current Regulation, and a Power Factor of 95% (typical)
The PDS Series comply with Power Supply Harmonics Current Regulations (IEC1000-3-2) as well as "Home Appliance and General-Purpose Products Harmonics Suppression Control Guidelines", and never affect the AC supply due to current harmonics. Furthermore with a built-in active smoothing filter, a resulting power factor of 95% (typical) is cleared.

Satisfying CE Mark Certification Requirements
These models satisfy Low-Voltage Standards (IEC1010) and EMC Standards Requirements.

Series/Parallel Operation
When these models are connected in series, the resulting output voltage is increased. And when they are connected in parallel, the resulting output current is increased. For more convenience, when a master-slave system is used, either a series drive or a parallel drive operation can be performed by a single unit in order to control the output of all of the other units.
(A master-slave system is possible with up to 3 units in parallel mode, and up to 2 units in series mode.)

Voltage/Current Simultaneous Digital Display
The bright and easy-to-see displays with 7-segment red LEDs are designed to display the voltage and current values digitally at the same time.

Voltage/Current Preset (3 points)
The frequently used output values for voltage and current can be stored in the memory for up to 3 points for each value. The preset values can be recalled with a touch of a button, making possible the switching of the output value more quickly.

Single-Dial Control Design
Designed with easy operation in mind, the operation conditions can be set at a press of the push button switch, while all the setup values can be changed using the rotary encoder control. Especially for output voltage and current, high accuracy control is possible in 10 mV and 10 mA steps respectively. Furthermore, the variable speed of the control knob can be switched between SLOW and FAST.

Key Lock Function
A key lock function is provided to fix the setup values for inhibiting the operation on the front control panel. This is convenient when long-term energization is required. Also, it is not necessary to have to worry about mis-operation by others if you leave it on your desk while the experiment is continuing.

Compact, Lightweight Design
When compared with the conventional PD-A Series, the weight is reduced to 1/2 to 1/3. It can more easily be carried from door to door than before.

Various Protection Functions
For protection, various protection functions are provided including OVP (over-voltage protection), OHP (over-heating protection) and OCP (over-current protection). When a protection circuit is engaged, the power switch is automatically turned off.

Board-Type Options for External Control
External control is possible using optional board interface. Since a board can be mounted inside the unit, no extra mounting space is required. For external control, three types of options are available -- analog (voltage/resistor), GP-IB and RS-232C.

Worldwide AC Voltage Input Design
A wide range of AC power voltages can be input between 90 V and 264 V. Each model is ready to accept worldwide power sources without switching over the voltage selector.




  Models, Options, & Accessories

Model Description List Price Sale Price
PDS20-36 0-20 Volt / 0-36 Amp, Digital Display - Discontinued - no replacement
Model Accessories List Price Sale Price
IF-30AN Analog control card for PDS series - Discontinued - no replacement
IF-30GP GP-IB control board for PDS series - Discontinued - no replacement
IF-30RS RS-232C control board for PDS series - Discontinued - no replacement
RK-605E EIA Rack Mount Adapter for PDS / PEL / PS Series - Discontinued - no replacement



  Specifications

Output
Output voltage range (V) 0 - 20
Output current range (A) 0 - 36
Rated output power (W) 720
Output terminal Rear
Voltage regulation characteristics
Line regulation 0.005% 1 mV (for ± 10% source voltage fluctuation)
Load regulation 0.005% 2 mV (for 0 to 100% fluctuation)
Ripple /noise, p-p
(By 20MHz Scope)
30 mVp-p
Ripple /noise, rms
(5 Hz to 1 MHz)
1.5 mVrms
Transient response (typ.) 100µsec
Temperature coefficient (typ.) ± 100 ppm/°C
Rise time (typ.) Full load / no load 100msec / 100msec
Fall time (typ.) Full load / no load 150msec / 1000msec
Current regulation characteristics
Line regulation 10mA
Load regulation 5mA
Ripple noise, rms (5 Hz to 1 MHz) 10mA
Temperature coefficient ± 100ppm/°C
Display
Voltage display, accuracy (23±5°C) 3 1/2 digits LED‚ 0.1% rdg ± 2 digits‚ 10mV accuracy
Current display, accuracy (23±5°C) 3 1/2 digits LED‚ 0.5% rdg ± 2 digits‚ 10mA accuracy
In constant voltage/ current operation CV LED on/ CC LED on
Output signals
Alarm signal output Open collector‚ active Low Operation functions (5ms one pulse)
Operation function
OVP key Displays OVP circuit operating voltage on front panel‚ which is variable between 10 and 110% of F.S
KEYLOCK (LOCAL) key Locks keys and knobs (except POWER switch). Also removes remote control
PRESET 1 - 3 keys Used with MEM key to memorize three output voltages and currents
MEM key Used with PRESET keys to memorize three output voltages and currents
FAST/SLOW key Changes output voltage and current setting speed
ON/OFF control Enabled with input contact signals
POWER switch shut-down Enabled with input contact signals
Output voltage remote sensing Compensates for 1 V voltage drop on single side
Protection
Over voltage protection (OVP) POWER switch off at setting value
Over current protection (OCP) POWER switch off at setting value
Overheat protection (OHP) POWER switch off at setting value
Soft OVP (OVD) Set from external controller in remote control mode. POWER switch off when soft OVP is active
Environmental request
Operating temperature / humidity range 0 to 40 °C / 30 to 80 % RH
Stocking temperature / humidity range -20 to 70 °C / 20 to 80 % RH
To-GND voltage ± 250 VDC
Cooling method Front air intake type forced air cooling with fan motor Insulation resistance
Power source
Input voltage AC 90 to AC 264 V‚ 50/60 Hz without setting change
Power factor (typ) 95%
Power consumption (typ) 1100 W
Power efficiency (typ) 65%
Dimensions / Weight
Dimensions (W ¥ H ¥ D) mm 210 × 124 × 405 (W × H × D)mm
Maximum dimensions (W ¥ H ¥ D) mm 210 × 141 × 465.5 (W × H × D)mm
Weight (approx.) 7.2 kg
Options
Analog I/O board V/I controlled by external voltage or resistance
GP-IB interface board V/I set/read‚ Output ON/OFF‚ AC shout down
RS-232C interfaceboard V/I set/read‚ Output ON/OFF‚ AC shout down
Output capacity extension Parallel connection control : Master-slave system‚ up to 3 units
Series connection control : Master-slave system‚ up to 2 units




 

Welcome | Companies | Search by Type | How To Order | Leasing | About Us | Careers | FAQ's | Privacy
  Tequipment.NET
205 Westwood Ave
Long Branch, NJ 07740
BBBOnline Reliability Seal, Click for confirmation page. Tequipment.NET
Phone: 1-877-571-7901 / 732-222-7077
Fax: (732) 222-7088
E-mail: salesteam@Tequipment.NET
 



Current Promotions

Quote Request

We Take POs, How To Order

Free Shipping on Select Premier Lines










' ' '