Features
  • High Stability, Large Capacity
  • Low Ripple, Low Noise
  • High-Accuracy Voltage and Current Settings
  • Remote Sensing
  • Remote Control
  • Voltage/Current Limiting
  • Parallel Operation
  • Series Operation
  • GP-IB System Compatibility
  • GP-IB System Compatibility
  • OUTPUT ON/OFF
  • OVP (Over-Voltage Protection)
  • OCP (Over-Current Protection)
  • OHP (Over-Heat Protection)
  • OHP (Over-Heat Protection)
  • LED Indicators
  • Output

 






  Description

The PD-A/AD Series power supplies are DC constant-voltage (CV), constant-current (CC) power supplies with variable output level featuring the use of the phase control method and high reliability. Inheriting the reliability and accuracy of the highly approved PD Series and incorporating a wide variety of protection facilities, the PD-A/AD Series power supplies have been designed with emphasis on the ease of operation and safety in use as research and experiment power supplies or long aging system power supplies. With 9 combinations of different voltage/current capacity values and the meter indication type and digital indication type models available for each of them, a total of 18 models offer a wide variation which can be selected according to applications.

High Stability, Large Capacity
A unique phase control method which uses a built-in pre-regulator ensures fast response and efficient high-stability supply of high currents.

Low Ripple, Low Noise
The unique phase control method is combined with a choke-input type smoothing circuit to provide excellent input and load variation rates, low ripple and low noise.

High-Accuracy Voltage and Current Settings
The output voltage as well as the output current can be set using 10-turn potentiometers, enabling smooth, fine setting.

Remote Sensing
This function compensates for the voltage drop at the load terminals which is caused by resistance of leads between the PD-A Series supply output terminals and the load and by output terminal contact resistance.

Remote Control
The output voltage and current can be controlled by means of an external DC voltage or resistance. In addition, it is also possible to remote control the OUTPUT ON/OFF by means of a contact switch.

Voltage/Current Limiting
A V/I CHECK switch is provided to allow setting the constant voltage and constant current setting values. The voltage and current values can be set and checked even while the output is ON.

Parallel Operation
By connecting the PD-A Series power supplies of the same model in a master-slave configuration, a single master can control all of the slave supplies. This parallel operation makes it possible to increase the output current.

Series Operation
The output voltage can be increased by series connection. A series connection in the master-slave mode of operation is also possible, with which a single master can control all of the slave supplies (provided that the allowable grounding voltage is within ±250 V.)

GP-IB System Compatibility
The voltage and current can be set with high accuracy through GP-IB by connecting the optional GP-610D GP-IB adapter. The OUTPUT ON/OFF can also be controlled through the GP-IB if the OP-12 EXT I/O unit (factory option) is added.

GP-IB System Compatibility
The voltage and current can be set with high accuracy through GP-IB by connecting the optional GP-610D GP-IB adapter. The OUTPUT ON/OFF can also be controlled through the GP-IB if the OP-12 EXT I/O unit (factory option) is added.

OUTPUT ON/OFF
The OUTPUT switch allows you to turn the output voltage on and off electronically. This can also be controlled externally by means of a contact switch.

OVP (Over-Voltage Protection)
The OVP protects the load from excessive voltage by switching the power off instantaneously in cases of operational mistakes or unexpected accidents. The OVP setting voltage can be displayed by pressing the OVP CHECK switch, and the setting can be made using a semi-fixed potentiometer on the front panel. The OVP setting voltage can be set or checked even while the output is on, without interrupting the use of the power supply.

OCP (Over-Current Protection)
The OCP protector circuits detects output current level above about 120% of the rated current and switches the power off.

OHP (Over-Heat Protection)
The OHP protector circuit detects the rise of heat sink temperature at about 100degree C and switches the power off.

OHP (Over-Heat Protection)
The OHP protector circuit detects the rise of heat sink temperature at about 100degree C and switches the power off.

LED Indicators
The green LED lights during constant-voltage operation and the red LED lights during constant-current operation.

Output
The output is supplied from 3 terminals based on the floating method.




  Models, Options, & Accessories

Model Description List Price Sale Price
PD56-10AD 0-56 Volts / 0-10 Amps, Digital Display - Discontinued - no replacement
Model Accessories List Price Sale Price
GP-610D GP-IB adapter for PD series, excluding OP-12 - Discontinued - no replacement
OP-12 External I/O unit for PD-A/AD series (factory option) - Discontinued - no replacement
RB-601 Blank Panel for RK-601, 1/2 rack width - Discontinued - no replacement
RK-601E EIA Rack Mount Adapter for PD-A / PD-AD Series - Discontinued - no replacement
CB-2420P GP-IB Cable (2m) - Discontinued - no replacement



  Specifications

Output
Output voltage 0 to 56V
Output Current 0 to 10A
Voltage regulation characteristics
Line regulation (with respect to ±10% variation in AC) 0.005% 1mV
Load regulation (with respect to change from 0 to 100%) 0.005% 2mV
Ripple/noise (10Hz to 1MHz)(typical) 0.5mVrms
Transient response 50µs
Remote control resistance/voltage 0 to 10kΩ/0 to 10V
Current regulation characteristics
Line regulation (with respect to ±10% variation in AC) 3mA
Load regulation (with respect to change from 0 to 100%) 5mA
Ripple/noise (10Hz to 1MHz)(typical) 3mArms
Remote control resistance/voltage 0 to 10kΩ/0 to 10V
Protective circuit
Temperature detection Approx. 100°C (power is shut off)
Over-voltage protection 15% to 110% of rated output voltage (power is shut off)
Input fuse rating (AC 100V/200V) 15A/8A
Meter and display
Voltmeter (2.5%) F.S. N/A
Ammeter (2.5%)F.S. N/A
Digital voltage display 3-1/2 digits, 19.99V, 199.9V (F.S.) two automatically switched ranges ± (0.1%rdg 1digit) 23°C±5°C, PH80% or less
Digital current display 3 digits or 3-1/2 digits
fixed range ±(0.5% of rdg 1 digit) 23°C±5°C
PH80% or less 99.9A(F.S.)
Constant-voltage operation display Green LED lights for CV
Constant-current operation display Red LED lights for CC
Output ON display Red LED lights when output is ON
Added functions
Output switch Output switchable ON/OFF (Incase of the OFF position, set output voltage is indicated the meter or LED display)
Voltage/current check switch Switch ON: indicates the regulated voltage or current on the meter or LED display
Over-voltage protection preset Switch ON: indicates the operating voltage setting of the over-voltage protection circuit
Remote sensing Possible
Series/Parallel control Master- slave operation
Operating environment
Temperature/humidity for operation 0 to 40°C, 80% or less
Cooling system Forced air (fan)
Output polarity Positive or negative side groundable
Groundable voltage ±250V DC
Power requirements/Others
Voltage 100V/120V/200V/220V/240V AC, 50/60Hz
Power consumption Approx. 0.8kW
Approx. 1.25kVA
Case dimensions (W×H×D) mm 208×147×348
Maximum dimensions (W×H×D) mm 208×168×394
(With power input connector mounted) 208×168×409
L1/L/L2 (mm) 23/348/23
Weight Approx. 18kg




 

Welcome | Companies | Search by Type | How To Order | Leasing | About Us | Careers | FAQ's | Privacy
  Tequipment.NET
205 Westwood Ave
Long Branch, NJ 07740
BBBOnline Reliability Seal, Click for confirmation page. Tequipment.NET
Phone: 1-877-571-7901 / 732-222-7077
Fax: (732) 222-7088
E-mail: salesteam@Tequipment.NET
 



Current Promotions

Quote Request

We Take POs, How To Order

Free Shipping on Select Premier Lines










' ' '