Kenwood DCS-8300 Digital Storage Oscilloscope
40MS/s 100MHz 2-Channel
   Search: HACKER SAFE certified sites prevent over 99.9% of hacker crime.
   

   
   




Kenwood DCS-8300 Digital Storage Oscilloscope
40MS/s 100MHz 2-Channel



Kenwood DCS-8300
Click image to enlarge

 Kenwood DCS-8300

Features:
  • 100 MS/s (1CH) High-speed sampling
  • Large capacity 16K words memory
  • TV line counter
  • Parameter Auto Measurement Function
  • Automatic setup function
  • Pre-trigger
  • Overwrite function
  • Single roll
  • ±2% accuracy
  • 100-Step Programming



  Description

The DCS-8300 offers you both easy operation part of an analog oscilloscope and high functionality part of a digital oscilloscope. As it employs high-intensity CRT high-speed single event can be observed easily.

The DCS-8300 has a variety of trigger functions to catch many different waveform. It also has a 40 MS/s AD converter in each channel and a maximum sampling speed of 100MS/s is achieved in 1 channel mode. A large capacity of 16K words memory for each channel makes long-term record storage possible. For front panel settings up to 100 steps can be storedC which enables recall of frequently used settingsC etc. by a touch of a button. A selection of optional interface (GP-IB or RS-232C) is also available. When these options are usedC the DCS-8300 can be controlled by PCC or waveform data can be stored in PC.

100 MS/s (1CH) High-speed sampling
When the DCS-8300 is used by the 1 channel mode, high-speed sampling at 100 MS/s is available. It is possible the measurement of high speed events. The highest sampling rate by 2 channel mode is 40 MS/s.

Large capacity 16K words memory
16K words of acquisition memory and 2K words of reference memory are provided for each channel.

TV line counter
For television signal synchro-nization, a line counter is also provided. By selecting the frame line number to be checked, the required line number can be observed.

Parameter Auto Measurement Function
It is possible to measure the voltage, frequency and period automatically just input the signal. Especially for voltage measurement, measurement mode is automatically selected according to the input selector. For example, when the AC input is selected, "Peak-to-Peak" voltage is automatically measured, and when the DC input is selected, DC voltage is measured automatically.

Automatic setup function
By pressing the AUTO SET key, setup operations for the voltage range and time range are automatically performed.

Pre-trigger
Observation of the waveform before the triggered point is possible. A maximum of 80 div. before triggering point can be observed.

Overwrite function
In this mode, the waveform of a signal subsequently input is displayed without erasing the currently displaying waveform. With this function, it is easy to observe the jitter component or amplitude fluctuation of the waveform.

Single roll
Setting "Single" in the roll mode enters the single roll mode. When the trigger signal is input at this mode, the displayed waveform freezed after the data corresponding to the value set for pre-triggering has been updated.

±2% accuracy
In order to obtain highly accurate measurements, both the voltage axis (except for 1mV, 2mV range) and the time axis ensure ±2% accuracy. (under ambient conditions of 10 to 35°C temperature and less than 85% humidity)

100-Step Programming
The DCS-8300 provided 100 steps programming capability for store/re-call operations for the front panel setting values. When the frequently used panel settings are previously programmed, they can be recalled with a touch of a button. This function greatly reduces the time required for measurements.

Options
When the optional GP-IB or RS-232C interface is installed, the DCS-8300 can be controlled by external controller. It is possible the control of the DCS-8300 from an external PC or stores the waveform data into the PC.




  Models, Options, & Accessories


Model Description List Price Sale Price
DCS-8300 40 MS/s 2CH, 100MS/s (CH1+CH2), 100M Real Time $5052.00
$4546.80 
Model Accessories List Price Sale Price
PC-51 150MHz Attenuator Probe, x10, w/readout pin $90.00
$81.00 
IF-10 GPIB adapter for DCS-7020/7040 $448.00
$403.20 
IF-20R RS-232C adapter for DCS-7020/7040 $448.00
$403.20 



  Specifications

Real-time block
CRT
Type 150mm rectangular, with internal graticule
Accelerating voltage Approx. 17kV
Effective area 8div. × 10div. (1div=10mm)
Vertical axis (Common for CH1, CH2)
Operating modes CH1, CH2, ADD, ALT, CHOP
Sensitivity 1mV/div., 2mV/div. : ± 5%
5mV/div. to 5V/div. : ± 2%
Attenuator 1mV/div. to 5V/div., 1-2-5 step, (fine adjustment)
Input impedance 1MΩ± 1%, approx. 20pF
Frequency response
DC DC to 100MHz, (-3dB)(5mV/div to 5V/div.)
DC to 20MHz, (-3dB)(1mV/div, 2mV/div.)
AC 5Hz to 100MHz, (-3dB)(5mV/div to 5V/div.)
5Hz to 20MHz, (-3dB)(1mV/div to 2mV/div.)
Rise time Approx. 3.5ns (5mV/div. to 5v/div.)
Approx. 17.5ns (1mV/div., 2mV/div.)
Signal delay time Can confirm the leading edge with the square wave that has a rise time less than the unit
Crosstalk Below -40dB (at 1kHz)
Polarity inversion CH2 only
CHOP Frequency Approx. 250kHz
Maximum input voltage 800Vp-p or 400V (DC AC peak)
Horizontal axis
Operating modes Set to X-Y mode by H MODE
CH1 : Y-axis
CH2 : X-axis
Sensitivity 1mV/div, 2mV/div : ± 5%
5mV/div to 5V/div : ± 3%
Input impedance Same as Vertical axis (CH2)
Frequency response
DC DC to 1MHz, (-3dB)
AC 5Hz to 1MHz, (-3dB)
X-Y phase difference Below 3 degrees at 100kHz
Maximum input voltage Same as vertical axis (CH2)
Sweep
Sweep modes A sweep. B sweep, ALT
Sweep time
A 0.5s/div to 50ns/div ± 2% in 1-2-5 steps
22 ranges, and fine adjustment
B 50ms/div to 50ns/div ± 2% in 1-2-5 steps
19 ranges
Magnified sweep × 10 ± 5% ( ± 8% less than 0.5µs/div)
Linearity ± 3% (10MAG ± 5%)
Delay mode Continuous delay, triggered delay
Delay time 0.5s/div to 50ns/div ; continuously variable from 0.2div.~10div
Delay time error ± (3% of set value 1% of f.s.) (0 to 300ns)
Delay jitter 10,000 : 1 of 10 times of the A sweep time
Hold off A Sweep : Continuously variable from NORM
Trace separation B separation from A is continuously adjustable to approx. ± 4 div
Triggering
Trigger sources VERT, CH1, CH2, LINE, EXT
Mode AUTO, NORM, FIX, SINGLE
Trigger coupling AC, HFrej, DC, TV-FRAME, TV-LINE
Trigger sensitivity
Trigger coupling Synced frequency range Internal sensitivity External sensitivity
NORM FIX NORM FIX
DC DC to 50MHz 1div. 1.5div. 100mV 150mV
50MHz to 100MHz 1.5div. 2div. 150mV 200mV
AC 10Hz to 50MHz 1div. 1.5div. 100mV 150mV
50MHz to 100MHz 1.5div. 2div. 150mV 200mV
HFrej Minimum triggering amplitude increases above 10kHz
TV TV-F, TV-LComp.video 1.5div. 1.5div. 150mV 150mV
Calibration voltage 1Vp-p ± 1% 1kHz ± 0.1%
External trigger
Input impedance 1MΩ ±1%, approx. 20pF
Max. input voltage 100Vp-p or 50V (DC AC Peak, 1kHz or less)
CH1 Signal output
Output voltage Approx. 50mVp-p/div
Output impedance Approx. 50Ω
Frequency response 5mV to 5V/div. : 100Hz to 100MHz (-3dB) 1mV to 2mV/div. : 100Hz to 20MHz (-3dB)
Trace rotation Enables trace rotation adjustment by semi-fixed controller on the panel
Storage block *Note : [ ] dual channel
Vertical axis
Vertical resolution 8bit (25dot/div.)
Dynamic range ± 5div
Effective storage frequency
DC DC to 40 MHz [16MHz] (sine interpolation)
AC 5Hz to 40 MHz [16MHz] (sine interpolation)
Effective rise time Below 16ns [40ns] (With linear interpolation)
frequency response
DC DC to 40MHz (- 3dB) (5mV/div to 5V/div)
DC to 20MHz (- 3dB) (1mV/div, 2mV/div)
AC 5Hz to 40MHz (- 3dB) (5mV/div to 5V/div)
5Hz to 20MHz (- 3dB) (1mV/div, 2mV/div)
Memory capacity
NORM sampling
Display memory (data) 2 KW/CH (200dot/div)
Display memory (REF) 2 KW/CH
Acquisition memory 16KW/CH
REF memory 2 KW/CH
Roll mode
Display memory (data) 2KW/CH (200dot/div.)
Display memory (REF) 2KW/CH
Acquisition memory 16KW/CH
REF memory 2KW/CH
Memory backup Battery backed up for approx. 30,000 hrs. (at normal temperature)
Acquisition memory 16KW/CH
REF memory 2KW/CH
Sweep time / Display mode
NORM sampling 50ns/div. to 500s/div.(50ns/div. to 1µs [2µs]/div. in the MAG range) (Maximum sampling rate : 100MS/s [40MS/s])
Peak detector 10µs/div. to 500s/div
Roll mode 0.2s/div. to 500s/div
Storage mode
AUTO Same as NORM for the same period, free-running data updating in other cases
NORM Data updated each time an acceptable trigger is received
SINGLE Data is storaged with the first acceptable triggering after resetting and held
AVG (Averaging) Average of 4 or 16 or 64 times
SMT (Smoothing) Data writing point will be averaged following 32 words
PST (Persistence) Mutual display of maximum and minimum values in storage, and initialization by PST RESET
PEAK 25ns glitch detection
ROLL
NORM Continuous recording and updating of data on the CRT.
SINGLE After receiving the acceptable trigger, the pre-triggering data is updated and the data is stored
Magnification, Compression
Magnification By pressing × 10 MAG under Hold conditions, 10-times magnification is obtained by linear interpolation around the CRT center
Interpolation Linear interpolation, sign interpolation
Trigger / Delay  
Pre-trigger NORM 0 to 10 div., 0 to 80 div (at 16KW/CH) (in 2.5div steps)
ROLL-SINGLE 0div. to 80div.(in 2.5div steps)
X-Y  
Effective storage frequency range DC to 16MHz (-3dB Adjustable sampling rate for the SWEEP TIME /DIV.)
External clock Carries out sampling by first transition of signals input from the external clock terminal when setting SWEEP TIME/DIV to EXT
Input impedance Approx. 10kΩ
Maximum input voltage 84Vp-p or 42V (DC AC peak, 1kHz or below)
Input signal level TTL
";L"; level : 0.8V or less
";H"; level : 2.7V or more
Input signal frequency range DC to 10MHz (1 kHz in roll mode)
Input signal duty ratio 20% to 80% (DC to 5MHz)
40% to 60% (5MHz to 10MHz)
Waveform calculation , -
Readout block
Panel setup value CH1/CH2 scale factor (with probe detector), V-UNCAL, ADD, INVERT, A/B Sweep scale factor (MAG calculation, "*" displayed in MAG mode), Sweep-UNCAL, DELAY TIME, B TRIG'D, X-Y, Sampling waveform in X-Y mode, Display scroll, setup value storage function, Pre-trigger point, REF memory setup condition, Menu, OUTPUT
Cursor measurement (ΔV1 only in X-Y mode) ΔV1 : Voltage display calculated using CH1 scale factor
ΔV2 : Voltage display calculated using CH2 scale factor
ΔT : Time display calculated using A sweep scale factor
Δ1/T : Frequency display calculated using A sweep scale factor
VOLTS/DIV or TIME/DIV UNCAL mode RATIO Voltage ratio/Time ratio display using 5 div. of screen readout as 100%
PHASE Phase difference display using 5 div. of screen readout as 360°
Resolution/Measurement accuracy 10 bits /± 4%
Measurement range Vertical ± 3.6 div. minimum from CRT center
Horizontal ± 4.6 div. minimum from CRT center
Parameter auto measurement Each parameter is measured and displayed for the selected signal as the sync signal source from either CH1 or CH2
Frequency (FRQ) Mode selectable in Cursor mode. Measurement/display calculated by internal counter
Frequency range 2 Hz to 100 MHz
Effective digits/Accuracy 3 digits / 0.01% ± 1 digit
Measurement sensitivity Same as trigger sensitivity
Period (PER) Mode selectable in Cursor mode. Measurement/display calculated by internal counter
Measurement range 0.5 s to 10 ns
Effective digits/Accuracy 3 digits / 0.01% ± 1 digit
Measurement sensitivity Same as trigger sensitivity
AC voltage (Vp-p) Mode selectable in cursor mode. Peak-to-peak voltage measurement /display
Measurement range 0.5 div. -- within effective screen area
Frequency range 10 Hz to 100 kHz
Effective digits/Accuracy 3 digits / 10 Hz to 40 Hz: ± {8% attenuator setup value V/div.) × 0.04 div.}, 40 Hz to 100 kHz: ± {3% attenuator setup value (V/div.) × 0.04 div.}
DC voltage (DCV) Mode selectable in cursor mode. Average DC voltage measurement /display
Sensitivity 0.5 div. -- within effective screen area
Effective digits/Accuracy 3 digits / ± {3% atte-nuator setup value (V/div.) × 0.04 div.}
Auto setup Automatically setup of Vertical axis attenuator, Sweep range, Vertical position, Horizontal position values for CH1 and CH2
Period 1.5 to 5 periods (H.VARIABLE CAL mode, with input signal up to 10 MHz)
Amplitude Within effective screen area (within 1/2 of effective screen area in 2-channel mode)
Frequency (sine wave) 50 Hz to 100 MHz
Position Vertical axis: Almost at CRT center in single phenomenon mode. 2-channel mode: Approx. 2 div. (CH1), approx. -2 div. (CH2) from the CRT center. Horizontal axis: Starts from the left end of on-screen scale
Program step Max. 100 steps (can be divided up to 5 groups)
Backup Panel setup values are backed up by built-in battery. Battery life: Approx. 30,000 hours (in room temperature). Factory-default values resume when built-in battery is expired
Power Supply block & Others
Power requirements & input voltage/Frequency AC 100/120/220/230 V (± 10% as input fluctuation), 50/60 Hz
Power consumption (AC 100 V input) Max. 77 W, 94 VA
Insulating voltage AC 1.5 kV, 1 minute
Insulating resistance 100MΩ or more with DC 500 V
Dimensions 305 (W) × 150 (H) × 400 (D) mm (344 × 165 × 459 mm, maximum dimensions)
Weight Approx. 9.9 kg
Operating environment (indoor use only)  
Altitude Below 2000 m
Overvoltage category II
Pollution 2
Operating temperature/humidity 0 to 40°C, below 85%
Storage temperature/humidity - 20 to 70°C, below 85%
Accessories Probe (× 2) PC-51: 10 MΩ ± 2%, 12.5 pF ± 10%, 1/10 Operation Manual (1) Adjusting screwdriver (1) Power cable (1)
Applicable standard  
Safety standard EN61010-I & A2 (1995)
EMI EN55011 (1991) CLASS B FCC47CFR, PART15, SUBPART B, CLASS B
Immunity IEC801-2 (1991) 8k VAD
IEC801-3 (1984) 3V/m
EIC801-4 (1988)
Options
OUTPUT Makes possible mounting of optional IF-10 or IF-20R (but simultaneous mounting is not possible)
IF-10 GP-IB interface (complies with IEEE-488 1978)
Operation Plots out the screen waveform and screen readout data to the GP-IB interface plotter. (TALK ONLY, HP-GL command) Outputs and inputs screen numerical data and outputs screen readout data through GP-IB interface computer. (TALK/LISTEN)
IF-20R EIA RS-232C interface
Operation Plots out the screen waveform and screen readout data to the RS-232C interface plotter. (HP-GL command) Outputs and inputs screen numerical data and outputs screen readout data through RS-232C interface. Prints out screen waveform and screen readout data with an RS-232C printer (only with the model DPU-412 available from SII (Seiko Instruments)). Outputs and controls panel setup data
Baud rate 9600/1200 bps
Transfer type Data length: 8 bits
Parity: none
Stop bit: 1 bit or more
Delimiter: CR LF
Handshake: CTS-RTS
RT-5371 Remote Controller
Operation Program step up/down/reset



   
  Welcome | Companies | Search by Type | How To Order | Leasing | About Us  
  Tequipment.NET
205 Westwood Ave
Long Branch, NJ 07740
For our Electronic Whiteboard division visit www.touchboards.com
BBBOnline Reliability Seal. Tequipment.NET
Phone: 1-877-742-TEST (8378) / 732-222-7077
Fax: (732) 222-7088
E-mail: salesteam@Tequipment.NET