The CS-5400 Series are 3-channel oscilloscopes developed with concepts of high level design‚high accuracy and easy operation. The panel layout never diminishes the intuitive and high-speed response provide fatigue free operation even after long-hours of use. These models incorporating readout function (with CS-5400 / 5450) offer you parameter measurement and auto setup functions enabling to measure AC voltage (Vp-p) ‚ DCvoltage‚frequency and period. All of these models are provided with full features including ±2% high-accuracy measurement‚delay sweep function‚automatic triggering and high intensity‚high-resolution CRT. The CS-5400 Series with high-performance will surely assist you in many kinds of field activities.
Parameter Auto Measurement Function
It is possible to measure the voltage, frequency and period automatically
just input the signal. Especially for voltage measurement, measurement
mode is automatically selected according to the input selector.
For example, when the AC input is selected, "Peak-to-Peak" voltage
is automatically measured, and when the DC input is selected,
DC voltage is measured automatically.
Auto Setup Function(CS-5400/5450)
By pressing the AUTO SET key, the voltage range and time range
are selected automatically.
Cursor Measurement Function(CS-5400/5450)
The cursor measurement function allows a high accuracy measurement
of signal values. When the probes are used, its attenuation ratio
can be converted automatically. It is also possible to measure
the voltage value and phase differences. When the delay sweep
is used, the delay time is also displayed, enabling an accurate
measurement results without any errors due to visual checks in
conventional systems.
Peak to Peak Voltage Measurement(CS-5400/5450) Parameter automatic measurement function enables automatic AC peak to peak voltage measurement up to 5MHz.
Variable Lock(CS-5400/5450) ON/OFF the vertical and horizontal variable functions can be set when pressing the ALT/CHOP knob more than 1-second. When OFF is selected, it becomes CAL level. When the function is ON, it returns to prior value.
3-Channel 8-Trace Waveform Display
CS-5400 series enable the display of CH3 input in addition to
CH1 and CH2. These three input signals to CH1, CH2 and CH3 can
be displayed at the same time as the main (A) sweep waveform.Furthermore,
an alternated delay sweep function displayed as the delayed (B)
sweep waveforms of each signal.
High-Sensitivity Design with Vertical Axis of 1 mV/div The vertical axis sensitivity can be varied continuously from 1 mV/div. to 5 V/div. using the 1-2-5 step attenuator. The 1 mV/div. position is very useful to measure low-level and complicated signals. (Frequency response at 1 mV/div. and 2mV/div are DC to 20 MHz (-3 dB)).
Automaticv Sync (FIX) Function With this function, the synchronization level is automatically controlled by tracking the amplitude of the waveform to maintain the sync lock status. This function eliminates annoying and complicated synchronization operations.
Easy Operation Panel Layout The CS-5400 and CS-5450 used touch switches and LEDs. The CS-5405 and CS-5455 used push switches and lever switches for easy operation.
Delayed Sweep with Waveform Partial Magnification Capability
The main (A) sweep waveform in which the magnified section is
brightened by intensity modulation and the delayed (B) sweep waveform
which shows only the magnified section can be observed simultaneously.
This is a real alternate delayed sweep.
V Mode Sync for Stable Display of 3 Signals Even when the CH1, CH2 and CH3 input signal frequencies are different, each signal can be synchronized securely and its waveform can be displayed stably.
High-Accuracy ± 2% Design for More Precision Measurement In order to obtain highly reliable measurement results, the vertical axis sensitivity and sweep time for the main circuit is maintained within ± 2% precision. Other specifications also guarantees the rated values (under temperature conditions of 10 to 35?C, humidity of 85% or less).
Maximum Sweep Rate of 5 ns/div (x10 MAG)
The sweep rate can be varied continually from 0.5 s/div to 50
ns/div. The signal delay line is installed so that the positive
rise of high-speed signals and high-frequency signals can be measured
accurately
Built in Video Clamp Circuit for Easy Operation Built in Video Clamp function which enables observation of the flame and line TV signals at the touch of a button, while high-stability synchronization is obtained without performing annoying synchronizing operations.
Square-Type 150 mm CRT with Self-Illuminated Light and Inside Scale (12 kV) A large-sized, square, dome-mesh type CRT with accelerator is employed. It features both high intensity and high resolution while providing accurate measurements without parallax view. The auto focus circuit is also incorporated to display sharp waveforms at all times.
Single Sweep for Observations of Single-shot Channel The single sweep function is powerful in measurement of single-shot or sudden channel. Waveform photography using a camera is as easy as ordinary, visual observations. It is easy not only for observations during normal visual inspections but also for camera shots of the waveforms.
Variable Hold-off Allowing Observation of Waveforms with Complicated Cycle Signals which are hard to be synchronized due to complicated repetition cycles, for example digital signals and video bursts signal, can be synchronized stably by converting them into the hold-off time.
High-Accuracy Calibration Signals A calibration signal output is provided to output the highly accurate frequency of ± 0.1% and voltage accuracy of ± 1%, enabling checking of the measurement precision at any required time.
CH1 Signal Output Connector The CH1 signal output is obtained by branching the input signal in the middle of the signal line. As this connector outputs the input signal at a rate of 50 mV/div, connecting a frequency counter makes it possible to measure the frequency of a very low signal while observing its waveform
Wide Dynamic Range and Distortion-Free Accurate Waveform Display Its wide dynamic range having greater margins assures the linearity of the waveforms displayed on the CRT, providing highly accurate waveform displays without any distortion up to the upper frequency limits.
Other Features All position knobs and controls are provided on the front panel. A High-sensitivity X-Y function is convenient for the measurement of phase differences between two input signals. A Trace Rotation function allows an easy correction of the inclination of the trace line due to earth magnetism. LINE Synchronization is provided A Trace Separation function shifts the B sweep waveform upward or downward by 4 div. from A sweep waveform. The waveform to which the brightness modulation is applied can also be observed. Added or extracted waveforms using ADD and CH2 INV functions can also be observed. Scale illumination convenient for taking photographs or observation in dark areas is provided. CRT scale also provides 0, 10, 90 and 100% indications; convenient for measurement of rising time, etc. A 10-times sweep waveform magnification function (X10 MAG) is provided.
|