Our agents are available:
9:00 AM - 6:00 PM EST
Iwatsu SS-7811A Analog Oscilloscope
   Search: HACKER SAFE certified sites prevent over 99.9% of hacker crime.
   
   
   



Iwatsu SS-7811A Analog Oscilloscope




Click image to enlarge




Quick auto setup (CH1, CH2)

SS-7847A/7840A/7830A/7821A/7811A/7810A
Click image to enlarge
Input signals are quickly shown in the optimum range.
Frequency counter

All models:
6-digit: SS-7847A/7840A/7830A,
5-digit: SS-7821A/7811A/7805A/7804A/7802A
Click image to enlarge
The built-in 6/5-digit counter is accurate within a range of ±0.0025% / ±0.01% and can measure frequencies between 2Hz and 400MHz. Also shows the trigger signal frequencies.
DC offset function (CH1, CH2)

SS-7847A/7840A/7830A
Click image to enlarge
Convenient when you need to observe a signal with very small amplitude superimposed over a signal with large amplitude. Especially useful when observing high-frequency noise superimposed over video signals or ripple of high-voltage DC power supply.
TV/HDTV triggering

TV: All models, HDTV: SS-7847A/7840A/7830A/7821A/7811A/7810A
Click image to enlarge
TV-V field (EVEN, ODD, BOTH) and line selection is possible for HDTV, NTSC, PAL/SECAM, meeting the needs of engineers who want to observe HDTV signals without any attenuation (even as low as 0.1 dB).
Pedestal clamp function (CH1, CH2) for TV signals

SS-7847A/7840A/7830A
Click image to enlarge
The amplitude of video signals varies dynamically depending on the picture. This function ensures stable observation.
CH2 skew adjust

SS-7847A/7840A/7830A
Click image to enlarge
The delay time of CH2 in response to CH1 can be adjusted with a range of 1 ns. Therefore, accurate measurement is possible by compensating for the delay time difference between the probes.
DC - 470MHz/400MHz/300MHz (all channels)
high-sensitivity of 2 mV/div (CH1, CH2)
DC - 470MHz (SS-7847A)/DC - 400MHz (SS-7840A)/DC - 300MHz (SS-7830A) for all channels. CH1 and CH2 have max. sensitivity of 2 mV/div, ensuring extremely high-quality waveforms.
IWATSU-developed bright, sharp CRT (Japan made)
SS-7847A/7840A/7830A/7821A/7811A/
7810A/7805A/7804A

Features superlative brightness and sharpness that even allows you to easily observe signals with slow repetition and a high-speed rise time transition.
IWATSU-developed preamp IC for improved signal stability
All models
To increase signal stability, a preamp circuit has been provided for the IC.
Panel settings save/recall function
All models
To increase signal stability, a preamp circuit has been provided for the IC.
Event trigger
All models
To increase signal stability, a preamp circuit has been provided for the IC.
Probe power supply provided as standard
All models
To increase signal stability, a preamp circuit has been provided for the IC.
Features:
  • DC - 3 CH, 100MHz, 8 traces
  • CH3 sensitivities: 50 mV, 100 mV, 500 mV/div
  • Max. sensitivity: 2 mV/div, fastest sweep of 1 ns/div
  • ±2% accuracy for vertical axis sensitivity
  • Display: 16 kV accelerating voltage CRT (Japan made)
  • Cursor measurement and panel settings readout function
  • Full TV triggering with field and line selection, HDTV
  • CH2 outpu
  • 5-digit frequency counter
  • Quick auto setup



Eye-patterns in optical disc manufacturing process
 

Click images to enlarge
 
When evaluating optical discs such as Blu-ray Discs, HD-DVDs, CDs or DVDs, eye patterns need to be observed. With this analog oscilloscope, accurate observation of the eye patterns of high-speed and high-density media is easily possible.
* Blu-ray Disc signal eye pattern waveform
Video head frequency modulation signals
 

Click images to enlarge
 
Input and output signals to/from video heads are frequency modulation waveforms. The voltage of recorded or read-out signals to/from the video heads is specified. To observe these FM signals, an analog oscilloscope is indispensable.
* VHS deck head signal waveform
ATM 155 Mbps signal eye patterns
 

Click images to enlarge
 
The standard transmission rate for most networked communication systems is 155 Mbps (STM-1). The amount of jitter can be estimated by observing the signal waveform with the eye pattern and following the pulse mask standard.
* 155 Mbps signal eye pattern waveform measured with SS-7847A (DC - 470MHz)
Full TV triggering
 

Click images to enlarge
 
TV-V (ODD field, EVEN field, BOTH fields) and TV-H are available. Line number selection in TV-V mode is useful for detailed evaluation of video signals. HDTV can be selected, as well as NTSC or PAL/SECAM (except for SS-7805A/7804A/7802A)
Switching power supply measurement


Click images to enlarge


A switching power supply unit with a higher harmonics measure switches the voltage of a commercial power supply at high speed. In terms of circuit operation, switching stops at the zero cross of the AC power supply. To observe this condition, an analog oscilloscope is required. Analog oscilloscopes are also superior when simultaneously observing voltage and current waveforms. In addition, when magnifying a switching waveform for observation on an analog oscilloscope, no complicated operations are required to trigger the waveform.



  Description

Convinent, Easy-To-Use, and High Performance



  Models, Options, & Accessories


Model Description List Price Sale Price
SS-7811A 100MHz, 3CH ANALOG OSCILLOSCOPE CE $3782.50
$3187.50 



  Specifications

 
SS-7821A
SS-7811/7810A
SS-7805A
SS-7804A
SS-7802A
Display
CRT 6-inch rectangular, internal graticule (8 x 10 div, with scale illumination) - Japan made 6-inch rectangular, internal graticule (8 x 10 div)
Accelerating voltage Approx. 16 kV 2 kV
Vertical deflection system
Mode CH1, CH2, CH3, ADD, ALT, CHOP CH1, CH2, ADD, ALT, CHOP
Frequency bandwidth  
5 mV/div - 5 V/div DC - 200MHz DC - 100MHz DC - 50MHz DC - 40MHz DC - 20MHz
2 mV/div DC - 50MHz DC - 50MHz DC - 20MHz DC - 20MHz DC - 10MHz
Sensitivity (CH1, CH2) 2 mV/div - 5 V/div 11-step (1-2-5), 2 mV - 12.5 V/div(with vernier)
Accuracy ±2%
Bandwidth limiter 20MHz Not provided
Rise time (Calculated from freq. bandwidth x rise time = 0.35) 1.75 nsec 3.5 nsec 7.0 nsec 8.75 nsec 17.5 nsec
Signal delay Available Not provided
Input coupling AC, DC, GND (The cut-off freq. Is 4Hz with AC coupl.)
Input RC - direct 1 Mω ±1.5% // 20 pF ±2 pF 1 Mω ±1.5% // 25 pF±2 pF
Max. input 1 Mω input : 400 V (DC + AC peak), with 10:1 probe : 600 V (DC + AC peak)
Polarity switching Possible only for CH2
Probe sensor 1:1, 1:10, 1:100 detection possible
Sensitivity (CH3) 50 mV/div, 100 mV/div, 500 mV/div, ±2% –
Input coupling AC, DC
Triggering
A triggering  
Source VERT, CH1, CH2, CH3, LINE VERT, CH1, CH2, EXT, LINE
Coupling AC, DC, HF-REJ, LF-REJ
Level  
DC - 5MHz 0.4 div 0.4 div 0.4 div 0.4 div 0.4 div
5MHz - 10MHz 0.4 div 0.4 div 1.0 div 1.0 div 1.0 div
10MHz - 40MHz 1.0 div 1.0 div 1.0 div 1.0 div 1.0 div (-20MHz)
40MHz - 50MHz 1.0 div 1.0 div 1.0 div
50MHz - 100MHz 1.0 div 1.0 div
100MHz - 200MHz 1.5 div
B triggering   Not provided
Source CH1, CH2, CH3, LINE
Coupling AC, DC, HF-REJ, LF-REJ
TV triggering NTSC, PAL/SECAM, HDTV NTSC, PAL/SECAM
Trigger mode TV-V (ODD, EVEN, BOTH) line number selectable, TV-H
EXT triggering input
Level
DC - 5MHz 80 mV 80 mV 80 mV
5MHz - 20MHz 200 mV 200 mV 200 mV
20MHz - 40MHz 200 mV
20MHz - 50MHz 200 mV
Max. input voltage 1 Mω : 400 V (DC + AC peak)
X-Y
X-axis CH1
Sensitivity Same as CH1
Accuracy ±3%
Bandwidth DC - 2MHz DC - 1MHz
Y-axis  
Operating channel CH1, CH2, CH3, ADD CH1, CH2 CH1, CH2
Horizontal deflection system
Horizontal display A, ALT, B, X-Y A, X-Y
Mode AUTO, NORM, SINGLE
A sweep time  
Fastest range with mag. 1 nsec/div 2 nsec/div 10 nsec/div 10 nsec/div 20 nsec/div
Slowest range 500 msec/div
B sweep time - Not provided
Fastest range with mag. 1 nsec/div 2 nsec/div
Slowest range 5 msec/div  
Accuracy A/B ±2%
Delay Triggered delay CH1, CH2, CH3
Continuous delay: RUNS AFTER
Delay jitters 1/20,000
Magnifier 10 times
Hold-off time Variable (up to sweep length or longer)
Auto setup V/H position, V/H range,trigger Not provided
Input channel CH1, CH2
Frequency response 50Hz - 50MHz –
CH2 signal output DC - 100MHz DC - 100MHz DC - 20MHz DC - 20MHz DC - 10MHz
Calibrator Square-wave, 1kHz±0.1%, 0.6 Vp-p±1%
CRT read-out  
Read-out Attenuator range, ADD UNCAL, AC/DC/GND, vertical mode, CH2 polarity, A/B sweep range,
x10 MAG, UNCAL, horizontal display mode, hold-off
Trigger coupling, trigger source, trigger slope, TV -field, TV-line, TV-system
Cursor measurement ΔV (voltage measurement), Δt (time measurement), 1/Δt(division calculation by Δt)
Frequency counter 5-digit, 0.01%
Frequency range 2Hz - 200MHz, reciprocal 2Hz - 100MHz, reciprocal 2Hz -50MHz, reciprocal 2Hz - 40MHz, reciprocal 2Hz - 20MHz, reciprocal
Save and recall Up to 32-setup (only for SS-7821A/SS-7811A) Not provided
Power off set-up Panel setting before switch is powered off
Back-up Battery back-up (approx. 30,000 hr)
Power supply AC 90 V - 132 V/180 V - 250 V, 50Hz - 400Hz, max. 110 VA AC 100 V/110 V - 120 V/220 V/ 230 V - 240 V, 50Hz - 60Hz
Dimensions and weight 272W x 152H x 390L mm, approx. 7.5 kg 272W x 152H x 390L mm, approx. 8.5 kg
Environment conditions
Operating 0°C - +40°C, 90% RH (40°C)
Performance guaranteed +10°C - +35°C
Standard accessories Power cable (x 1), probe (x2), fuse (x2), panel cover (x1), operation manual (x 1) Power cable (x 1),probe (x 2), panel cover (x 1),operation manual (x 1)



   
  Welcome | Companies | Search by Type | How To Order | Leasing | About Us  
  Tequipment.NET
205 Westwood Ave
Long Branch, NJ 07740
For our Electronic Whiteboard division visit www.touchboards.com
BBBOnline Reliability Seal. Tequipment.NET
Phone: 1-877-742-TEST (8378) / 732-222-7077
Fax: (732) 222-7088
E-mail: salesteam@Tequipment.NET