Iwatsu DS-8814can Digital Oscilloscope

Click image to enlarge
|
|
Features:
- All-in-one type, with CAN bus trigger functions, data display,
and compact size
- Built-in card slot and floppy disk drive
- 4-channel model
- DC - 100MHz frequency bandwidth
- 400MS/s sampling rate
- 100 kwords/channel acquisition memory
- ±2% of vertical accuracy
|
Description
| The BRINGO is now reborn as the even more
powerful BRINGO II. In response to customer requests, the frequency
bandwidth of all models has been upgraded 150 MHz. The BRINGO II
lineup, which also includes models without a built-in printer, offers
outstanding cost performance. All models also feature convenient
program oscilloscope functions. Now more affordable and more easy
to use than ever, BRINGO is always evolving. |
Models, Options, & Accessories
| Model |
Description |
List Price |
Sale Price |
| DS-8814can |
Please call or email us for pricing and availability. |
| Model |
Accessories |
List Price |
Sale Price |
| SS-0130 |
Please call or email us for pricing and availability. |
| HV-P30 |
1000:1, 50MHz, 30kV |
$2893.70 |
| $2512.95 |  |
|
| HV-P60 |
2000:1, 50MHz, 60kV |
$5667.52 |
| $4776.00 |  |
|
| SK-301 |
High-voltage probe stand |
$532.00 |
| $462.00 |  |
|
| SS-240 |
Please call or email us for pricing and availability. |
| PS-26 |
POWER SUPPLY for CURRENT PROBE SS-240 CE |
$796.10 |
| $691.35 |  |
|
| GR-AF |
Please call or email us for pricing and availability. |
| FP-2S |
Please call or email us for pricing and availability. |
| FP-7 |
Please call or email us for pricing and availability. |
| FP-7L |
Please call or email us for pricing and availability. |
| HP-2 |
Please call or email us for pricing and availability. |
| BB-50M10 |
Please call or email us for pricing and availability. |
| BB-50M1 |
Please call or email us for pricing and availability. |
| RS-232C |
Please call or email us for pricing and availability. |
| DS-535 |
Please call or email us for pricing and availability. |
| DS-536 |
Please call or email us for pricing and availability. |
| TP80-1 |
Please call or email us for pricing and availability. |
| DS-539 |
Please call or email us for pricing and availability. |
| DS-525 |
Please call or email us for pricing and availability. |
| DS-534 |
Please call or email us for pricing and availability. |
Specifications
| Configuration at time of measurement |
 |
| Series |
BRINGO
II |
BRINGO |
| Form |
DS-8824P |
DS-8824 |
DS-8822P |
DS-8822 |
DS-8814P |
DS-8814can |
DS-8812P |
| Frequency bandwidth |
150MHz |
100MHz |
150MHz |
| Input CH |
4 |
2 |
4 |
2 |
| Acquisition memory |
100 k-point/CH |
| External interfaces |
| RS-232 |
YES |
| GP-IB |
YES* |
NO |
YES* |
NO |
YES* |
Option:
DS-534 |
| Floppy disk drive |
YES |
NO |
YES |
NO |
YES |
| PC card slot |
YES (ATA
card slot) |
| Built-in printer |
YES |
NO |
YES |
NO |
YES |
| Program functions |
YES |
NO |
| CAN bus trigger |
NO |
YES** |
NO |
* The optional dedicated cable
(DS-539) is required.
** Choose from reception trigger, ID trigger, data trigger, bit
trigger, and error trigger. Communication ID and data display functions
are also available. |
| |
BRINGO II |
BRINGO |
Form |
DS-8824P |
DS-8824 |
DS-8822P |
DS-8822 |
DS-8814P |
DS-8814can |
DS-8812P |
| Frequency bandwidth |
150MHz |
100MHz |
150MHz |
| Input CH |
4 |
2 |
4 |
2 |
| Display |
5.8-inch LCD display
(backlit EL), Blue color,
320 x 240 dots (115.17 x 86.37 mm) |
| Max. sampling rate |
at CH1, CH3 (2CH): 400MS/s
When 4CH used: 200MS/s |
at CH1 (1CH): 400MS/s
When 2CH used: 200MS/s |
at CH1, CH3 (2CH): 400MS/s
When 4CH used: 200MS/s |
500MS/s |
| Equivalant sampling |
10GS/s |
10GS/s |
25GS/s |
| Peak detect |
5ns |
5ns |
2ns |
| Acquisition memory |
100 k-point/CH |
| Resolution |
8 bits |
| Volt range |
2mV/div to 10V/div |
| Accuracy |
±2% |
| Max. input voltage |
±400V (DC
+ ACpeak) |
| Bandwidth limit |
10MHz |
| Input coupling |
AC, DC, GND |
| Input RC |
1MW±1.5%//20pF±2pF |
| Probe attenuation |
1:1, 10:1, 100:1,
1000:1
(1:1, 10:1, 100:1 are automatically detected) |
| Probe |
SS-0130R (150MHz,
10MW, 12.5pF, 10:1) |
| Calibration signal |
0.6V±1%,
1kHz±0.01% |
| Time base range |
5ns/div to 50s/div |
| Roll mode |
Short [1 k-point/CH
(5 k-point/CH for DS-8812P)]: 100ms/div to 50s/div,
Long [100 k-point]: 2s/div to 50s/div |
| Persistance |
YES |
| Clock accuracy |
50ppm |
| Trigger mode |
Auto, Normal, Single |
| Trigger function |
Edge, Event (COUNT,
BURST, EXTRA, MISSING), TV (NTSC, PAL, SECAM) |
| CAN bus trigger |
NO |
YES*1 |
NO |
| EXT trigger input |
NO |
100mV/div (Fixed) |
NO |
100mV/div (Fixed) |
| External interfaces |
| |
RS-232 |
YES |
| GP-IB |
YES*2 |
NO |
YES*2 |
NO |
YES*2 |
Option:
DS-534 |
| Floppy disk drive |
YES |
NO |
YES |
NO |
YES |
| PC card slot |
YES (ATA card slot) |
| Built-in printer |
YES |
NO |
YES |
NO |
YES |
| Automatic measurement |
Tr, Tf, Vrms, Vmean,
freq, Period, +PW, -PW, Duty, +Peak, -Peak, P-P, Skew |
Top, Base, T-B,
Dt, Area, CVrms, CVmean,
+Oshot, -Oshot, +Pulse, -Pulse |
- |
| Cursor measurement |
DV, Dt, 1/Dt, V
at t simultaneous 4-cursor display available |
| Zoom |
Y-axis: Scaling
within voltage sensitivity setting range,
X-axis: Scaling at center of screen |
| Waveform arithmetic |
CH1+CH2, CH1-CH2,
CH1xCH2, FFT
(CH3+CH4, CH3-CH4, CH3xCH4 for 4CH models) |
| Average |
2 to 256 times (Short
acquisition memory only) |
| Frequency counter |
5-digit, ±0.01%,
1Hz to 150MHz (DS-8814P, DS-8814can: 1Hz to 100MHz) |
| Program mode |
The panel setting
can be changed by dedicated
and
keys |
NO |
| Environmental conditions |
Performance: 10°C
to 35°C,
Operation: 0°C to 40°C, less than 80% RH,
Storage: -10°C to +60°C, less than 80% RH |
| Dimentions |
Approx. 215(W) x
170(H) x 166(L) mm (excluding protruding parts) |
| Weight |
Approx. 3kg |
Approx. 2.7kg |
Approx. 3kg |
Approx. 2.7kg |
Approx. 3kg |
| Voltage range |
AC 100 to 240 Vrms,
50/60 Hz |
| Power consumption |
100VA |
85VA |
90VA |
75VA |
110VA |
90VA |
| Accessories |
Probe (2 or 4),
Power cable (1), Fuse (2), Operation manual (1), Thermal paper: for
"P" model only (1) |
*1 A trigger box that supports
the DS-8814can (Simple-CAN2) is required. The DS-8814can CAN bus trigger
function is not supported by the GP-IB interface.
*2 The optional dedicated cable (DS-539) is required. |
| Vertical deflection
system |
Input |
Analog 4 channels + CAN bus trigger |
| Sensitivity (bandwidth and accuracy) |
2mV/div (DC to 100MHz, -3.5dB, ±2%)
5mV/div to 10V/div (DC to 100MHz, -3dB, ±2%) |
| Triggering |
Triggering mode |
Edge, Event, TV, CAN |
| Signal source |
CH1, CH2, CH3, CH4, LINE, CAN bus |
| Horizontal deflection system |
Time base range |
5ns/div to 50s/div |
| Acquisition function |
Resolution |
8 bits |
| Max. sampling rate |
400MS/s (2CH), 200MS/s (4CH) |
| CAN bus Communication Specification |
Communication speed |
33.3 kbps/50.0 kbps/83.3 kbps/95.2 kbps/100
kbps/125 kbps/250 kbps/500 kbps/1 Mbps |
| Sampling point |
Variable |
| Communication ID format |
Standard format (11 bits)/extended format (29
bits) |
| CAN bus trigger functions |
Reception trigger |
Reception trigger function in which trigger
is synchronized with all CAN frames |
| ID trigger |
ID trigger function in which four IDs can be
specified |
| Data trigger |
Data trigger function in which trigger is synchronized
with data frames containing specified ID and data
Any 1-byte data can be set with one ID and in increments
of one byte.
Any data length between 1 and 8 bytes can be specified
in increments of one byte.
Data can be specified in increments of one bit using
the mask function. |
| Bit transition trigger |
Bit transition trigger function in which trigger
is synchronized with specified bit-condition transition of data containing
specified ID
One ID and any 1-bit data can be set.
Any data length between 1 and 8 bytes can be specified
in increments of one byte.
Transition of the specified bit can be specified (0 to
1 and vice versa). |
| Error trigger |
Error trigger function in which trigger is
synchronized with any stuff, CRC, or form error.
This function can be ORed with another trigger. |
| Trigger delay |
There is a delay of about 30ms
between reception of a CAN frame (completion of EOF) and the occurrence
of the trigger. |
| Other CAN bus functions |
Data display function |
In the single mode, the ID and data are displayed
after a waveform is obtained.
Data in the center of the screen is displayed in hexadecimal
format at the bottom of the screen. |
| Other |
Power supply |
100 to 240 V AC, 50/60 Hz |
| Dimensions |
215mm x 170mm x 167mm (excluding protruding
parts) |
|