Instek LCR-815B LCR Meter
Click to Enlarge Image
|
Features:
- Measures capacitance, Resistance and Inductance
- Measures dissipation factor of capacitors and 1/Q of inductors
- Auto Ranging and Up, Down manual range
- Auto Circuit Mode Selection
- Test Frequency 120Hz and 1kHz
- High Accuracy 0.2%
- Test Fixture LCR-03(Option)
|
| Model |
Description |
List Price |
Sale Price |
| LCR-815B |
LCR Meter 120 Hz, 1 KHz - Discontinued - replaced by Instek LCR-816 |
Click here to download the Instek LCR-800-series manual (PDF)
Specifications
| Test Frequency |
120Hz, 1kHz |
| Basic Accuracy |
0.2% |
| Test Signal Level |
1V, 50mV (Cp mode only) |
| DC BIAS |
| Internal |
1.5V, 2.2V, 6V |
| External |
0 ~ 30V |
| Display Range |
| Impedance/Resistance R |
1900mW ~ 19.00MW |
| Capacitance C |
190pF ~ 19.00mF |
| Inductance L |
190mH ~ 1900H |
| Dissipation Factor D |
0.001 ~ 1.900 |
| Equivalent Circuit |
AUTO, Parallel, Series |
| Trigger |
Internal, External, Manual |
| Display |
3 1/2 digital, max. display 1999 |
| Power Source |
AC 100V/120V/220V/240V + 10%, 50/60Hz |
| Accessories |
Power cord x 1, Instruction manual x 1, LCR-02, (option LCR-03) |
| Dimensions & Weight |
310(W) x 100(H) x 395(D) mm, Approx. 5.5kg |
|