(150kHz ~ 1000MHz)

FEATURES:
yball.gif (937 bytes) Frequency Range : 150kHz ~ 1000MHz
yball.gif (937 bytes) Fully Digital Phase Locked Loop Technique Design
yball.gif (937 bytes) High Frequency Stability : ±10ppm
yball.gif (937 bytes) High Resolution of Span to Measure the more detailed signal : Zero,  2kHz ~ 100MHz /DIV
yball.gif (937 bytes) RBW : 3k, 30k, 220k, 4M
yball.gif (937 bytes) High Input Protection Level : +30dBm, ±25VDC
yball.gif (937 bytes) Reference Level Range : -30dBm ~ +20dBm
yball.gif (937 bytes) Good Noise Floor Performance : -95dBm @30kHz, -100dBm typical ; over -150dBm/Hz typical @220kHz and 4MHz RBW
yball.gif (937 bytes) Spurious Noise :<-60dB
yball.gif (937 bytes) Intermodulation (3rd) :<-70dBc
yball.gif (937 bytes) Two Markers for Absolute and Relative Measurement
yball.gif (937 bytes) Functions : Max. Hold, Average (2 ~ 32 traces), Freeze, Peak Search, Marker to Center Function
yball.gif (937 bytes) 9 Memories of Save/Recall
yball.gif (937 bytes) RS-232 Interface and Display Software to get Trace from GSP-810 to PC
yball.gif (937 bytes) Options :Power Meter, Tracking Generator, Remote Control Software
yball.gif (937 bytes) Tracking Generator: With the tracking generator option, the GSP-810 enables you to measure the characteristics of the device under test, such as filter or RF power amplifier. In addition, it provides a normalization feature to "calibrate out" the gains and losses in the cables and other devices under test.
yball.gif (937 bytes) Power Meter: With the power meter, GSP-810 can measure the total power of input signal in the units of mW or dBm.


Model Description List Price Sale Price
GSP-810 Spectrum Analyzer - 150KHz-1GHz $2375.00
$2137.50 
GSP-810TG Spectrum Analyzer - with Tracking Generator $3275.00
$2947.50 
GSP-810PM Spectrum Analyzer - with Power Meter $2945.00
$2650.50 
GSP-810TGPM Spectrum Analyzer - with Tracking Generator & Power Meter $3560.00
$3204.00 
Model Accessories List Price Sale Price
ATA-001 BNC Antenna - BNC to N Adapter may be required for use on certain models $30.00
$27.00 
GTL-301 RF Cable $65.00
$58.50 
GSP-810 Software Remote Control Software for GSP-810 $210.00
$189.00 
GSP-810 Cable 3' Cable with N type male connector (for GSP-810) $65.00
$58.50 

When ordering ATA-001, BNC to N Adapter required (sold seperately).

Click here to download the Instek GSP-810 manual (PDF)

More Accessories

SPECIFICATIONS  
FREQUENCY
Frequency Range 150kHz ~ 1000MHz
Frequency Resolution 1kHz C.F. entry, 40Hz Sweep resolution at 2kHz/DIV
Frequency Display 6 1/2 digit setting
Frequency Control Digital phase locked
Frequency Stability ±2ppm/year aging,±10ppm, 0 to 50°C
Frequency Spans Zero, 2kHz to 100MHz/DIV, in a 1-2-5 sequence

BANDWIDTH
Resolution Bandwidths 3kHz,30kHz, 220kHz, 4MHz
Resolution BW Accuracy 15%
Video Bandwidth 1.6kHz/90kHz coupled with RBW

AMPLITUDE
Reference Level Range -30dBm to +20dBm
Reference Level Accuracy ±1dB at 80MHz
Input Level Range -100dBm to +20dBm
Noise Floor -95dBm@30kHz RBW, -100dBm typical/-75dBm:150kHz ~ 10MHz
Amplitude Display Range 75dB
Amplitude Accuracy ±1.5dB typical@0dBm, 80MHz
Amplitude Level Linearity ±1.5dB over 70dB
Ref. Level Freq. Flatness ±1.5dB over 100MHz, ±2.5dB typical over entired band/±3dB:150kHz ~10MHz
Harmonic Spur Response <-40dBc, RF input < selected reference
Non-Harmonic Spur Response <-60dBc typical down from reference level, average, 5MHz/div
Intermodulation(3rd) <-70dBc, @-40dBm input, 2 tones, 2MHz apart/<-45dBc:150kHz ~10MHz
Phase Noise -77dBc/Hz at 1GHz, 30kHz offset

INPUT
Input Overload Protection +30dBm continuous, ±25VDC
Impedance 50 ohm nominal
Return Loss <16 dBRL (VSWR < 1.35)
Input Attenuation 50dB to 0dB in 10 dB steps coupled to reference level
Connector Type N female

MARKER
Number of Markers 2
Marker Resolution 0.1dB, 1kHz
Marker Mode Absolute, Relative, PK -> Marker, Marker -> Center
Marker Accuracy 0.1dB±amplitude accuracy

FUNCTIONS
Memory 9 memories of save/recall
Trace Max. Hold, Average(2 ~ 32 traces), Freeze(Hold)
Setup Access parameters

FM/AM DEMODULATOR
WB FM 120kHz deviation
MB FM 75kHz deviation
NB FM 30kHz deviation
AM Outputs Internal speaker, 3.5mm stereo jack, wired for mono operation

REMOTE DISPLAY SOFTWARE & RS-232
Connecting to PC and getting trace from GSP-810, software will be downloaded from here

GENERAL
Power Source 100/120/220/230V AC±10%, 50/60Hz
Accessory Operation manual x 1
Dimensions and Weight 310(W) x 150(H) x 455(D)mm, approx. 8.5kg

OPTIONS
TRACKING GENERATOR (OPTION 01)
Frequency Range 10MHz to 1000MHz
Amplitude Range 0 to -50dBm
Amplitude Resolution 1dB
Amplitude Accuracy ±1dB@0dBm, 80MHz
Attenuation Accuracy ±1dB@, 50MHz
Amplitude Flatness ±1dB@, 10MHz/DIV, ±1.5dB@0dB,entire band
Harmonics <-30dBc
Reverse Power <+30dBm
Impedance 50 ohm nominal
Return Loss <10 dBRL (VSWR<2)
Connector Type N female

POWER METER (OPTION 02)
Frequency Range 10MHz to 2GHz, usable to 2.7GHz
Power Level Range -20dBm to +23dBm, usable to +30dBm
Power Level Overload +40dBm<10% duty cycle, <10mS duration
Return Loss <1:1.35 VSWR into 50 ohms, <1:1.25 typical
Readout Resolution 0.2mW, 100mW scale, 2µW, 1mW scale; 0.1dB, Log scale
Accuracy ±(10% rdg ±1digit)
Readout mW or dBm

REMOTE CONTROL SOFTWARE (OPTION 03)
Connecting PC to get trace and provide the control for setting




   
  Welcome | Companies | Search by Type | How To Order | Leasing | About Us  
  Tequipment.NET
205 Westwood Ave
Long Branch, NJ 07740
For our Electronic Whiteboard division visit www.touchboards.com
BBBOnline Reliability Seal. Tequipment.NET
Phone: 1-877-742-TEST (8378) / 732-222-7077
Fax: (732) 222-7088
E-mail: salesteam@Tequipment.NET