FEATURES
 

yball.gif (937 bytes) GRS-6052: DC~50MHz, 100MSa/s, 2kW/CH x 2
GRS-6032: DC~30MHz, 100MSa/s, 2kW/CH x 2

yball.gif (937 bytes) 2 Channels, 4 Traces
yball.gif (937 bytes) Equivalent Time Sampling of 500MSa/s max.
yball.gif (937 bytes) Waveform SAVE / RECALL (M0~M9)
yball.gif (937 bytes) Pre-trigger Function 0 ~ 10 div.
yball.gif (937 bytes) ROLL Mode to 100s/div.
yball.gif (937 bytes) Max. Sweep Rate 10ns/div.
yball.gif (937 bytes) Cursor Readout Function: △V, △T, 1/△T
yball.gif (937 bytes) ALT-MAG Function (x5, x10, x20)
yball.gif (937 bytes) Panel Setting SAVE / RECALL 10 sets. (M0~M9)



Model Description List Price Sale Price
GRS-6032A Oscilloscope, 30MHz, 100MS/s (Analog/Digital) $995.00
$895.50 
Click here to download the Instek GRS-6032 manual (PDF)

Accessories

SPECIFICATIONS
CRT
Type GRS-6052: 6-inch CRT 150CTB31, 10kV
GRS-6032:
6-inch CRT D14-363GY, 2kV
INTEN and FOCUS Front panel control
Illumination Front panel control
Z-axis Output Sensitivity: at least 5V (TTL)
Polarity: positive going input decrease intensity
Max.input voltage: 30V (DC+AC peak)
GRS-6052: Input impedance: approx. 47kΩ
GRS-6032:
Input impedance: approx. 33kΩ

VERTICAL SYSTEM
Sensitivity and Accuracy 1mV ~ 2mV/DIV±5%, 5mV ~ 20V/DIV±3%, 14 calibrated steps in 1-2-5 sequence
Variable Continuously 2.5:1 ~ min. 50V/DIV
Bandwidth (-3dB) and Rise Time
   
Bandwidth(-3dB)
Rise Time
GRS-6052 5mV ~ 20V/DIV
DC ~ 50MHz
Approx. 7nS
1mV ~ 2mV/DIV
DC ~ 7MHz
Approx. 50nS
GRS-6032 5mV ~ 20V/DIV
DC ~ 30MHz
Approx. 11.7nS
1mV ~ 2mV/DIV
DC ~ 7MHz
Approx. 50nS
Vertical Mode CH1, CH2, DUAL(ALT or CHOP)
Chopper Frequency Approx. 250kHz
Sum or Difference CH1+CH2, CH1-CH2
Invert CH2
Input Impedance Approx. 1MΩ±2% // approx. 25pF
Input Coupling AC, DC, GND
Maximum Input Voltage 400V (DC + AC peak)

HORIZONTAL SYSTEM
Sweep Time 0.2µS/DIV ~ 0.5S/DIV, 20 steps selectable in 1-2-5 sequence
Variable Continuously 2.5:1 UP TO 1.25s/DIV (uncal.)
Accuracy ±3%, ±5% at x5, x10 MAG. ±8% at x20 MAG
Sweep Magnification x5, x10, x20
Max. Sweep Time GRS-6052: 20nS/DIV (10nS/DIV are uncalibrated)
GRS-6032: 50nS/DIV (10nS/DIV ~ 40nS/DIV are uncalibrated)
ALT-MAG Function YES
HOLD-OFF Time Variable

TRIGGER SYSTEM
Trigger Modes AUTO, NORM, TV
Trigger Source VERT, CH1, CH2, LINE, EXT
Trigger Coupling AC, HFR, LFR, TV-V(-), TV-H(-)
Trigger Slope "+" or   "-" polarity
ALT Trigger YES
Trigger Sensitivity
GRS-6052
CH1,2
VERT -MODE
EXT
20Hz ~ 5MHz
0.5 DIV
2.0 DIV
200mV
5MHz ~ 40MHz
1.5 DIV
3.0 DIV
800mV
40MHz ~ 50MHz
2.0 DIV
3.5 DIV
1V
GRS-6032
CH1,2
VERT -MODE
EXT
20Hz ~ 5MHz
0.5 DIV
2.0 DIV
200mV
5MHz ~ 40MHz
1.5 DIV
3.0 DIV
800mV
TV sync pulse more than 1 DIV (CH1, CH2, VERT-MODE) or 200mV(EXT)
External Trigger Input Input Impedance: Approx. 1MΩ // 25pF (AC coupling)
Max. input voltage: 400V (DC+AC peak) at 1kHz

X-Y OPERATION
Input X-axis:CH1 ; Y-axis:CH2
Sensitivity 1mV/DIV ~ 20V/DIV
Bandwidth X-axis: DC ~ 500kHz (-3dB)
Phase Difference 3º or less from DC to 50kHz

DIGITAL STORAGE
Acquisition Memory
 
8 bit ADC x 2
Maximum Sampling rate 500MS/s for Equivalent time sampling
100MS/s for normal sampling
Storage Bandwidth Single shot:DC~5MHz(-3dB)
Repetivivevent:
GRS-6052: DC~50MHz ±5DIV
GRS-6032: DC~30MHz ±5DIV
Dynamic Range ±5DIV
Memory Length Acquisition Memory: 2kW/CH*2, 1kW/CH(equivalent)
Save REF Memory: 1kW/CH*10 with back-up memory
Display memory: 1kW/CH*4 waveform (max.)
Sweep Time Equivalent: 0.2µs/DIV~0.5µs/DIV
Normal: 1µs/DIV~0.1s/DIV
ROLL: 0.2s/DIV~100s/DIV
Sweep Magnification
 
x5, x10, x20
Max. Sweep Time
 
10ns/DIV
MAG Interpolation
 
DOT, Linear
ALT-MAG Function
 
YES
Acquire Mode
 
Sample, Peak Detect(>25ns), Envelop, Per-sist, Average(2~256)
Operation Mode
 
Auto, Norm, Single, Single-Roll, Roll, X-Y, Average(2~256), Run/Stop
Smoothing Function
 
Dot joint ON/OFF selectable
Pre-Trigger
 
0~10DIV in 0.02DIV steps
X-Y Operation
 
X-axis: CH1, Y-axis: CH2
Storage Bandwidth:
GOS-6052: DC~50MHz(-3dB)
GOS-6032: DC~30MHz(-3dB)
Display Resolution
 
H:100points/DIV ; V:25 points/DIV
X-Y: 25*25 points/DIV
Waveform SAVE/RECALL
 
10 sets (REF0~REF9)

CURSOR READOUT Cursor Measurement
 
ΔV, ΔT, 1/ΔT
Readout Intensity Adjustable

OUTPUT SIGNAL
CH1 Signal Output Voltage: approx. 20mV/DIV (with 50Ω terminated);
Bandwidth: 50Hz~5MHz
Calibrator Output Voltage: 0.5V ±3%
Frequency: approx. 1kHz,  Square wave

INTERFACE
 
RS-232C Interface

POWER SOURCE AC 100V/120V/ 230V + 10%, 50/60Hz

ACCESSORIES Power cord x 1, Instruction manual x 1, Probes(10:1/1:1) x 2

DIMENSIONS & WEIGHT 275(W) x 130(H) x 370(D) mm, Approx. 7.2kg





 

Welcome | Companies | Search by Type | How To Order | Leasing | About Us | Careers
  Tequipment.NET
205 Westwood Ave
Long Branch, NJ 07740
BBBOnline Reliability Seal, Click for confirmation page. Tequipment.NET
Phone: 1-877-571-7901 / 732-222-7077
Fax: (732) 222-7088
E-mail: salesteam@Tequipment.NET
 



Live chat by BoldChat
Need help? We have a staff
of more than 30 people to help you.
Let us show you why over 100,000
customers choose Tequipment.NET