Specifications
|
| Output |
| |
Voltage |
Current |
Tracking Series Voltage |
Tracking Parallel Current |
| Ch 1 |
0 ~ 25V |
0 ~ 0.5A |
0 ~ 50V |
0 ~ 1A |
| Ch 2 |
0 ~ 25V |
0 ~ 0.5A |
0 ~ 50V |
0 ~ 1A |
| Ch 3 |
3~6V |
2.5A Fixed |
- |
- |
| Ch 4 |
8~15V |
1A Max. |
- |
- |
|
| Constant Voltage Operation (Ch1, Ch2) |
| Line Regulation |
≤ 0.01% + 3mV |
| Load Regulation |
≤ 0.01% + 3mV (rating current ≤ 3A) ≤ 0.02% + 5mV (rating current > 3A) |
| Ripple & Noise |
≤ 1mVrms 5Hz ~ 1MHz |
| Recovery Time |
≤ 100µS (50% Load change, Minimum load 0.5A) |
|
| Constant Current Operation (Ch1, Ch2) |
| Line Regulation |
≤ 0.2% + 3mA |
| Load Regulation |
≤ 0.2% + 3mA |
| Ripple & Noise |
≤ 3mArms |
|
| Tracking Operation (Ch1, Ch2) |
| Tracking Error |
≤ 0.5% + 10mV of the Master |
| Series Regulation |
≤ 300mV |
| Load Regulation |
≤ 0.01% + 3mV |
| Ripple & Noise |
≤ 2mVrms 5Hz ~ 1MHz |
|
| 3V ~ 6V Output (Ch3) |
| Line Regulation |
≤ 5mV |
| Load Regulation |
≤ 15mV |
| Ripple & Noise |
≤ 2mVrms, 5Hz ~ 1MHz |
| Voltage Accuracy |
± 5% rdg |
| Current Output |
2.5A |
|
| 8V ~ 15V Output (Ch4) |
| Line Regulation |
≤ 5mV |
| Load Regulation |
≤ 10mV |
| Ripple & Noise |
≤ 2mVrms, 5Hz ~ 1MHz |
| Current Output |
1A |
|
| Meter |
| Digital |
3 digits 0.5" LED display
Out ON Accuracy ±(5% rdg + 2 digits)
Out OFF Accuracy ±(5% rdg + 8 digits) |
|
| Insulation |
| Chassis and Terminal |
≥ DC 500V / 20MΩ |
| Chassis and AC Cord |
≥ DC 500V / 30MΩ |
|
| Power Source |
| AC 100V/120V/220V+10%, 230V+10%~-6%, 50/60Hz |
|
| Accessories |
Instruction manual x 1,
Power cord x 1,
Test lead GTL-105 x 4 or GTL-203 x 2, GTL-204 x 2 |
|
| Dimensions & Weight |
| 255(W) x 145(H) x 265(D) mm, Approx. 7 kg |
|