| Constant Voltage Operation |
Line Regulation: |
£0.01% +3mV |
| Load Regulation: |
£0.01% +5mV (rating current <10A)
£0.02% +5mV (rating current ³10A) |
| Ripple and Noise: |
£1mVrms 5Hz ~ 1MHz |
| Recovery Time: |
£100µs (50% load change, minimum load 0.5A) |
| Output Range: |
0V to rated voltage, continuously adjustable |
| Constant Current Operation |
Line Regulation: |
£0.2% +3mA |
| Load Regulation: |
£0.2% +3mA |
| Ripple Current: |
£3mArms |
| Output Range: |
0A to rated current, continuously adjustable |
| Meter |
Meter Type: |
Analogue voltmeter and analogue ammeter
2.5 class |
| Meter Size: |
Each meter 50mm x 50mm |
| Insulation |
Chassis and Terminal: |
20MW or above (500V DC) |
| Chassis and AC Cord: |
30MW or above (500V DC) |
| Other Details |
Power Source: |
AC 100V/120V/220V/240V ±10%, 50/60Hz |
| Accessories: |
Power cord x 1, Instruction manual x 1, Test lead (type GTL-104) x 1 |
| Dimensions: |
255mm (w) x 145mm (h) x 335mm (d) |
| Weight: |
11.5kg |