| SPECIFICATIONS |
CONSTANT
VOLTAGE
OPERATION |
Regulation |
Line regulation < 0.01% + 3mV |
| Load regulation < 0.01% + 3mV |
| Ripple & Noise |
< 0.5mVrms 5Hz ~ 1MHz |
| Recovery Time |
< 100µS (50% Load change, Minimum load 0.5A) |
| Temp. Coefficient |
< 300ppm/°C |
| Output Range |
0 to rating voltage continuously adjustable |
|
CONSTANT
CURRENT
OPERATION |
Regulation |
Line regulation < 0.2% + 3mA
Load regulation < 0.2% + 3mA |
| Ripple Current |
< 3mArms |
| Output Range |
0 to rating amperes continuously adjustable
(Hi /Lo range switchable) |
|
| METER |
Analog |
V-meter and I-meter each one
2.5 class
Dimension 50 x 50 mm |
|
| INSULATION |
Chassis and Terminal |
20MΩ or above ( DC 500V ) |
| Chassis and AC Cord |
30MΩ or above ( DC 500V ) |
|
| POWER SOURCE |
AC 120V+10%, 50/60Hz (220V, 240V order mode) |
|
| ACCESSORIES |
Instruction manual x 1,
Power cord x 1,
Test lead GTL-105 x 1 |
|
| DIMENSIONS |
102(W) x 165(H) x 300(D) mm |