Features:
  • 200MHz Bandwidth

  • Dual Channel

  • Delayed Sweep

  • Built-in 6 Digit Universal Counter

  • Auto Set

  • TV Line Selection (NTSC, PAL, SECAM)

  • 10 Front Panel Setting Memories

  • Cursor Readout with 7 Measurements

 


Model Description List Price Sale Price
GOS-6200 Analog Oscilliscope - 200MHz, cursor readout $2025.00
$1822.50 

Click here to download the Instek GOS-6200 manual (PDF)

Accessories

Specifications

CRT Type: 6-inch  rectangular type with internal graticule; 0%, 10%, 90% and 100% markers; 8 x 10 DIV (1 DIV = 1 cm)
Phosphor: P31
Accelerating Potential: 14kV approx
Illumination: Continuously adjustable
Z-Axis Input: Coupling: DC
Sensitivity: 5V or more
Maximum input voltage: 30V (DC + AC peak) at 1kHz or less
Bandwidth: DC ~ 5MHz
Vertical System Sensitivity: 2mV ~ 5V/DIV, 11 step in 1-2-5 sequence
Sensitivity Accuracy: £ 3% (5 DIV at the centre of display)
Vernier Vertical Sensitivity: Continuously variable to 1/2.5 or less of panel-indicated value
Bandwidth (-3dB): DC ~ 200MHz (2mV/DIV : DC ~ 20MHz)
Rise Time: 1.75ns (2mV/DIV : 17.5ns)
Signal Delay: Leading edge can be monitored
Maximum Input Voltage: 400V (DC + AC peak) at 1kHz or less
Input Coupling: AC, DC, GND
Input Impedance: 1MW ±2% // approx 25pF
Vertical Modes: CH1, CH2, DUAL (CHOP/ALT), ADD, CH2 INV
Bandwidth Limited: 20MHz
Common Mode Rejection Ratio: 50:1 or better at 50kHz
Dynamic Range: 8 DIV at 100MHz; 5 DIV at 200MHz
Horizontal System Horizontal Modes: MAIN (A), ALT, DELAY (B)
A (Main) Sweep Time: 20ns ~ 0.5s/DIV, continuously variable (UNCAL)
B (Delay) Sweep Time: 20ns ~ 50ms/DIV
Accuracy: ±3% (±5% at x 10 MAG)
Sweep Magnification: x 10 (maximum sweep time 2ns/DIV)
Hold Off Time: Variable
Delay Time: 1µs ~ 5s
Delay Jitter: Better than 1:20000
Alternate Separation: Variable
Trigger Trigger Modes: AUTO, NORM, TV
Trigger Source: CH1, CH2, LINE, EXT, EXT/10
Trigger Coupling: AC, DC, HFR, LFR, NR
Trigger Slope: + or - polarity or TV sync polarity
Trigger Sensitivity:
Mode Frequency INT EXT EXT/10
AUTO 10Hz ~ 20MHz 0.35 DIV 50mV 500mV
20MHz ~ 200MHz 1.5 DIV 150mV 1.5V
NORM DC ~ 20MHz 0.35 DIV 50mV 500mV
20MHz ~ 200MHz 1.5 DIV 150mV 1.5V
TV Sync signal 1 DIV 200mVpp 2Vpp
Trigger Level Range: INT: ±4 DIV or more; EXT: ±0.4V or more; EXT/10: ±4V or more
TV Triggering: Mode: TV-V, TV-H, TV-LINE
TV-Line Selection:
Standard Field 1 Field 2
NTSC (525H) 1H ~ 263H 1H ~ 262H
PAL (625H) 1H ~ 313H 1H ~ 312H
SECAM (625H)
Max. External Input Voltage: 400V (DC + AC peak) at 1kHz
External Input Impedance: 1MW ±5% // approx 25pF
X-Y Operation Mode: X-axis: selectable CH1, EXT, EXT/10; Y-axis: selectable CH1, CH2, CH1 and CH2
Sensitivity Accuracy: 2mV ~ 5V/DIV ±3%; EXT: 0.1V/DIV ±5%; EXT/10: 1V/DIV ±5%
X-Axis Bandwidth: DC ~ 500kHz (-3dB)
Phase Error: 3º or less from DC ~ 50kHz
Output Signal Trigger Signal Output: Voltage: approx 25mV/DIV into 50W; Frequency response: DC ~ 10MHz
Calibrator Output: 1kHz square wave, 2Vpp ±2%
Cursor Readout Function Cursor Measurement Function: DV, DV%, DVdB, DT, 1/DT, DT%, Dq
Cursor Resolution: 1/100 DIV
Effective Cursor Range: Vertical: ±3 DIV; Horizontal: ±4 DIV
Panel Setting Display: Vertical: V/DIV (CH1, CH2), UNCAL, ALT/CHOP/ADD, INV, probe factor, AC/DC/GND
Horizontal: S/DIV (MTB, DTB), UNCAL, x 10 MAG, delay time, HO
Trigger: source, coupling, slope, level, TV-V, TV-H
Others: X-Y, lock, save/recall MEM 0-9
Auto Measurement Function Parameter Function: FREQ, PERIOD, ±WIDTH, ±DUTY (+ or - polarity selected by trigger slope)
Display Digits: Max 6 digits, decimal
Frequency Range: 50Hz ~ 200MHz
Accuracy: 1kHz ~ 200MHz: ±0.01%; 50Hz ~ 1kHz: ±0.05%
Measuring Sensitivity: > 2 DIV (measuring source selected from CH1 and CH2 as synchronous signal sources)
Special Functions Auto Set: Input channel: CH1, CH2; Frequency response 50Hz ~ 50MHz
Panel Setting Save and Recall: 10 sets
Panel Setup Lock: Provided
Other Details Power Source: AC 100V/120V/230V ±10%, 50/60Hz
Accessories: Power cord x 1, Instruction manual x 1, Probe (10:1/1:1) x 2
Dimensions: 310mm (w) x 150mm (h) x 470mm (d)
Weight: 9kg approx





 

Welcome | Companies | Search by Type | How To Order | Leasing | About Us | Careers
  Tequipment.NET
205 Westwood Ave
Long Branch, NJ 07740
BBBOnline Reliability Seal, Click for confirmation page. Tequipment.NET
Phone: 1-877-571-7901 / 732-222-7077
Fax: (732) 222-7088
E-mail: salesteam@Tequipment.NET
 



Live chat by BoldChat
Need help? We have a staff
of more than 30 people to help you.
Let us show you why over 100,000
customers choose Tequipment.NET