FEATURES G
yball.gif (937 bytes) 2 Channels, 4 Traces¡G
   DC ~ 30MHz (GOS-6030/6031)
   DC ~ 50MHz (GOS-6050/6051)
yball.gif (937 bytes) 1mV/DIV ~ 20V/DIV
yball.gif (937 bytes) CRT Readout
yball.gif (937 bytes) Cursor Measurement, 6 Digit Frequency Counter, 10 Sets Memory for Front Panel Setting Save & Recall (GOS-6031/6051)
yball.gif (937 bytes) ALT MAG Function (x5, x10, x20)
yball.gif (937 bytes) Vertical Mode Triggering
yball.gif (937 bytes) TV Synchronization
yball.gif (937 bytes) CH1 Signal Output, Z-axis Input
yball.gif (937 bytes) Buzzer Alarm & LED Indicators
yball.gif (937 bytes) Compact size (275W x 130H x 370D mm) and Front Panel Layout Groups for easy to use


Model Description List Price Sale Price
GOS-6030 30Mhz Analog Oscilloscope, Cursor $650.00
$585.00 
GOS-6031 30Mhz Analog Oscilloscope, Cursor, Recall & Counter $740.00
$666.00 
GOS-6050 50Mhz Analog Oscilloscope, Cursor $850.00
$765.00 
GOS-6051 50Mhz Analog Oscilloscope, Cursor, Recall & Counter $925.00
$832.50 
Click here to download the Instek GOS-6000-series manual (PDF)


SPECIFICATIONS
CRT
Type
6-inch rectangular type with internal graticule; 0%, 10%, 90% and 100% markers. 8 x 10 DIV (1 DIV=1 cm)
Accelerating Potential
GOS-6051/6050 approx.10kV
GOS-6031/6030 approx.2kV
INTEN and FOCUS
Front panel control
Illumination
Provided (GOS-6031/6051)
Trace Rotation
Provided
Z-axis input
Sensitivity: at least 5V
Polarity: positive going input decrease intensity
Usable frequency range: DC to 2MHz
Maximum input voltage: 30V (DC+AC peak) at 1kHz or less
GOS-6051/6050 Input impedance: approx. 33k£[
GOS-6031/6030 Input impedance: approx. 47k£[

VERTICAL SYSTEM
Sensitivity and Accuracy
1mV ~ 2mV/DIV + 5%, 5mV ~ 20V/DIV + 3%, 14 calibrated steps in 1-2-5 sequence
Vernier Vertical Sensitivity
Continuously variable to 1/2.5 or less panel indicate value
Bandwidth (-3dB) and Rise Time
 
 
Bandwidth(-3dB)
Rise Time
GOS-6051/6050
5mV ~ 20V/DIV
DC ~ 50MHz
Approx. 7nS
1mV ~ 2mV/DIV
DC ~ 7MHz
Approx. 50nS
GOS-6031/6030
5mV ~ 20V/DIV
DC ~ 30MHz
Approx. 11.67nS
1mV ~ 2mV/DIV
DC ~ 7MHz
Approx. 50nS
Maximum Input Voltage
400V (DC + AC peak) at 1kHz or less
Input Coupling
AC, DC, GND
Input Impedance
1M£[ + 2% // approx. 25pF
Vertical Modes
CH1, CH2, DUAL (CHOP, ALT), ADD, CH2 INV
CHOP Frequency
Approx. 250kHz
Dynamic Range
GOS-6031/6030:8 DIV at 20MHz, 6 DIV at 30MHz
GOS-6051/6050:8 DIV at 40MHz, 6 DIV at 50MHz

HORIZONTAL SYSTEM
Sweep Time
0.2µS/DIV ~ 0.5S/DIV, 20 steps selectable in 1-2-5 sequence, continuous variable control between steps at least 1¡G2.5
Accuracy
+ 3%, + 5% at x5, x10 MAG. + 8% at x20 MAG
Sweep Magnification
x5, x10, x20 MAG
Maximum Sweep Time
(at MAG)
GOD-6051/6050: 20nS/DIV (10nS/DIV are uncalibrated)
GOD-6031/6030: 100nS/DIV (10nS/DIV ~ 40nS/DIV are uncalibrated)
ALT-MAG Function
Available

TRIGGER
Trigger Modes
AUTO, NORM, TV
Trigger Source
VERT-MODE, CH1, CH2, LINE, EXT
Trigger Coupling
AC, HFR, LFR, TV-V(-), TV-H(-)
Trigger Slope
"+" or   "-" polarity
Trigger Sensitivity
GOS-6051/6050
20Hz ~ 5MHz
5MHz ~ 40MHz
40MHz ~ 50MHz
GOS-6031/6030
20Hz ~ 2MHz
2MHz ~ 20MHz
20MHz ~ 30MHz
CH1, CH2
0.5 DIV
1.5 DIV
2.0 DIV
VERT-MODE
2.0 DIV
3.0 DIV
3.5 DIV
EXT
200mV
800mV
1V
TV sync pulse more than 1 DIV (CH1, CH2, VERT-MODE) or 200mV(EXT)
External Trigger Input
Input Impedance¡GApprox. 1M£[ // 25pF (AC coupling)
Max. input voltage¡G400V (DC + AC peak) at 1kHz
Hold-off Time
Variable

X-Y OPERATION
Input
X-axis¡GCH1¡FY-axis¡GCH2
Sensitivity
1mV/DIV ~ 20V/DIV
Bandwidth
X-axis¡GDC ~ 500kHz (-3dB)
Phase Difference
3º or less from DC to 50kHz

OUTPUT SIGNAL
Trigger Signal Output
Voltage¡G approx. 20mV/DIV (with 50£[ terminated)¡F
Bandwidth¡G50Hz to at least 5MHz
Calibrator Output
Voltage¡G0.5V + 3%¡FFrequency¡Gapprox. 1kHz,  Square wave

CURSOR READOUT
Panel Setting Display
CH1/CH2 sensitivity, sweep time, trigger condition
Panel Setting Save & Recall (GOS-6031/6051)
10 sets
Cursor Measurement
(GOS-6031/6051)
Cursor measurement function¡G£GV, £GT, 1/£GT
Cursor resolution¡G1/25 DIV¡F
Effective cursor range¡Gvertial: + 3 DIV, horizontal: + 4 DIV
Frequency Counter
(GOS-6031/6051)
Display digits¡GMax. 6-digits decimel
Frequency range¡GGOS-6051¡G50Hz ~ 50MHz¡FAccuracy¡G+ 0.01%
Frequency range
¡GGOS-6031¡G50Hz ~ 30MHz¡FAccuracy¡G+ 0.01%
Measuring sensitivity¡Gmore than 2 DIV (measuring source selected from CH1 or CH2 as synchronous signal sources)

POWER SOURCE
AC 100V/120V/ 230V + 10%, 50/60Hz

ACCESSORIES
Power cord x 1, Instruction manual x 1, Probes(10:1/1:1) x 2

DIMENSIONS & WEIGHT
275(W) x 130(H) x 370(D) mm, Approx. 7.2kg





 

Welcome | Companies | Search by Type | How To Order | Leasing | About Us | Careers
  Tequipment.NET
205 Westwood Ave
Long Branch, NJ 07740
BBBOnline Reliability Seal, Click for confirmation page. Tequipment.NET
Phone: 1-877-571-7901 / 732-222-7077
Fax: (732) 222-7088
E-mail: salesteam@Tequipment.NET
 




Fluke Sponsored March Madness Bracket Challenge

Quote Request

We Take POs, How To Order

Free Shipping on Select Premier Lines










Live chat by BoldChat
Let our engineers and cs staff help!
Need a quote? Need to check stock?
Have a technical question? No problem.
We are here to help.