| Insulation |
| Test Voltage Accuracy |
-0% + 30% (over full operating temperature) into 0 to 1mA load |
| Measuring Range |
0,01MΩ - 999MΩ(Digital)0,1MΩ - ∞(Analog) |
| Short Cct. Current |
Less than 2mA |
| Output Noise Voltage |
Typically 2V pk to pk at 20kHz (at 1mA load) |
| Hum Rejection |
<10% error with 100μA RMS (0,2MΩ - %infin;) |
| Continuity |
| Measuring Range: |
0.01Ω - 99.9Ω |
| Open Cct. Voltage |
5V ± 1V |
| Lead res. comp |
0 - 9.99Ω |
| Hum Rejection |
<3% error with 1V RMS(0.2 - 50 Omega;) |
| Environmental Conditions |
| Temperature Coefficient |
<0,1% per °C |
| Humidity |
90% RH at 40°C max |
| General Specifications |
| Display |
3 digit L.C.D. Maximum reading 999 |
| Auto Shut off |
Operates after 5 minutes of inactivity by the instrument in Continuity position and 12 minutes in Insulation position. Beep notes pre-empt auto shut off. The instrument can be switched back on by pressing the test button, or by selecting ‘OFF‘ and then the required position. |
| Default Voltmeter Ranges |
25V - 450V a.c. 50/60 Hz ± 2% ±3 digits 450V - 600V a.c. 50/60 Hz ± 3% d.c. - unspecified |
| Power Supply |
6 x 1,5V cells IEC LR6 type only |
| Fuse |
500 mA (F) H.B.C.10 kA min (32mm x 6mm) |
| Weight |
530g (including batteries) |