| GENERAL |
| Characteristics Description |
Display 4 Digit LCD, 9999 count display |
| Conductor Size |
23mm (0.9”) approximately |
| Overrange Indication |
“OL” |
| Sampling Rate |
0.4 seconds |
| OPERATING ENVIRONMENT |
| Relative Humidity |
4 °C to 50 °C (14 °F to 122 °F) 85% Relative Humidity |
| Storage Environment |
-20 °C to 60 °C (-4 °F to 122 °F) at <75% relative humidity |
| Power source |
9V Battery (NEDA 1604) |
| Battery Life |
150 hours typical (alkaline) |
| Low Battery Indicator |
Symbol indicates low battery voltage |
| Power Consumption |
40mA |
| Over-Load Protection |
Current 100A Continuous, 200A < 60 seconds (50/60 Hz) |
| Dimensions |
257mm L x 100mm W x 47mm D, 10.1” H x 3.9” W x 1.9” D |
| Weight |
Approximately 640 g or 1.4 lbs. including battery |
| RANGES and ACCURACY SPECIFICATION |
| Measurement Characteristics |
(All at 23°C ± 5°C, < 80% R.H.) ± ([% of reading] + [number of digits]). |
| Additional Temperature Coefficient |
(4 °C ~ 18 °C and 28 °C ~ 50 °C ± 0.15% per °C) |