| Certifications and compliances |
| Safety |
Designed to EN 61010-1, EN 61010-2-032, UL 61010B-1, UL 61010B-2-032 specifications 1000V DC Category III 600V DC Category IV 750V AC Category III Input rating : 600V AC Category IV CAT IV: Outside and service entrance. CAT III: Distribution level mains, fixed installation. CAT II: Local level mains, appliances, and portable equipment. |
| Over voltage category |
CAT I: Signal level, special equipment or parts of equipment, telecommunication, electronics. |
| General specifications |
| Characteristics |
Description |
| Display |
3 3/4 Digit LCD display |
| Display Count |
4000 count, maximum reading 3999 |
| Over range |
Indication “OL” is displayed |
| Sampling Rate |
2.0 time/second |
| Operating Relative Humidity |
0°C to 50°C (32°F to 122°F) 0 ~ 70% RH |
| Storage Environment |
-20°C to 60°C (-4°F to 140°F) at <80% relative humidity Power source : 9V Battery (NEDA 1604) |
| Battery Live |
200 hours typical (alkaline) {61-772} 150 hours typical (alkaline) {61-774} |
| Low Battery Indicator |
symbol indicates low battery voltage |
| Auto power off |
Approximately 30 minutes |
| Dimensions |
10.6” H X 4.1” W X 1.9” D 270mm H X 103mm W X 48.5mm D |
| Maximum Cable Size |
ACA 2” (51mm) |
| Weight |
Approximately 17.6 oz. or 500g including battery |
| RANGES and ACCURACY SPECIFICATION |
| Accuracy |
Accuracy specifications at 23°C ±5°C (73.4°F ±9°F) less than 75% RH. Temperature Coefficient : 0.1 times the applicable accuracy specification per degree C from 0°C to 18°C and 28°C to 50°C (32°F to 64°F and 82°F to 122°F) Electrical Specification : Accuracy are ±(reading plus number of digits) at 23°C ±5°C <75% RH |
| AC Converter |
True RMS Sensing |
| Overload Protection |
AC and DC Voltage not to exceed 1000V DC or 750V AC RMS Resistance : Not to exceed 600V DC or AC RMS Capacitance |
| Continuity |
not to exceed 600V DC or VAC RMS |