| General |
| Displays |
3-3/4 digit LCD with 4000 counts for both displays |
| Backlight |
Green illumination with auto-off after 4.5 minutes |
| Analog Bargraph |
41 segment LCD with measurements of 20 times per second |
| Polarity |
Automatic, positive implied, negative (-) polarity indication. |
| Overrange |
"OL" indication is displayed. |
| Zero |
Automatic |
| Measure Rate |
Samples 2 times per second, nominal. |
| Auto Power Off |
Approximately after 30 minutes of non-use. |
| Battery Life |
400 hours continuous with Alkaline (61-764) 200 hours continuous with Alkaline (61-766) 150 hours continuous with Alkaline (61-768) |
| Low Battery Indication |
The " " is displayed when battery voltage drops below operating level. |
| Power Supply |
(1) 9V battery (NEDA 1604, JIS 006P, IEC 6F22) Includes an isolated battery compartment. |
| Accuracy |
Stated accuracy at 23°C ±5°C, <75% R.H. |
| Temperature |
0.1 x (specified accuracy) per °C, |
| Coefficient |
(0°C to 18°C, 28°C to 50°C). |
| Altitude |
6561.7 ft. (2000m) |
| Operating Environment |
32°F to 122°F (0°C to 50°C) at < 70% R.H. |
| Storage Environment |
-4°F to 140°F (-20°C to 60°C) at < 80% R.H. with battery removed from meter |
| Jaw Opening |
Accepts a 1.42" (36mm) conductor |
| Dimensions |
8.7”H x 3.1”W x 1.8”D (222mmH x 80mmW x 45.5mmD) |
| Weight |
12.3 oz (350g) including battery |
| Accessories included |
Carrying Case, Test Leads with alligator clip, (1) 9V battery, operating instructions. |
| Safety |
Complies with EN 61010-1, EN 61010-2-032, UL 61010-1, IEC 61010-2-032, IEC61010-031 specifications, Cat IV-600V/Cat III-1000V. |
| Double Insulation |
Instrument has been evaluated and complies with insulation category II (overvoltage category II). Pollution degree 2 in accordance with IEC-644. Indoor use. |
| Ranges & Accuracies |
| AC Converter |
61-764 model is averaging sensing, rms calibrated, 61-766, 61-768 models are true rms sensing. |
| Accuracy |
Accuracy is specified as +/-(a percentage of the reading + a fixed amount) at 23°C±5°C (73.4°F ± 9°F), less than 75% relative humidity. |
| Temperature Coefficient |
0.1 times the applicable accuracy specification per degree C from 0°C to 18°C and 28°C to 50°C (32°F to 64°F and 82°F to 122°F) |