| Model |
Description or Specification |
|
RS Series
Type: General / Field grade
Basic Accuracy: 0.1% (or better)
to 1%
Range: .001Ω -100 MΩ
Max. Resolution: 10 mΩ
Features: Economical, toolbox size |
|
RCS Series
Type: Field grade Resistance and Capacitance
Box
Basic Accuracy: 0.1% (or better)
to 1%
Range: .001Ω -100 MΩ
Max. Resolution: 10 mΩ
Features: Consists of an RS Resistance Box, and
a CS Capacitance Box |
|
OhmSource
Type: Elec-Res Box
Basic Accuracy: 0.10%
Range: 0.5 Ω - 24 MΩ
Max. Resolution: 10 mΩ
Features: Economical, microprocessor controlled |
|
GenRad 1433
Type: High accuracy
Basic Accuracy: 0.01%
Range: 0-111 MΩ
Max. Resolution: 1 mΩ
Features: Laboratory grade |
|
HARS-X
Type: High accuracy
Basic Accuracy: 0.01%
Range: 0-111 MΩ
Max. Resolution: 1 mΩ
Features: Laboratory grade, high accuracy, high
stability, low zero resistance, low temperature coefficient, suitable
for RTD simulation. |
|
HARS-Q/A/B
Type: High accuracy
Basic Accuracy: 0.02% - 0.05%
- 0.1%
Range: 0-111 MΩ
Max. Resolution: 1 mΩ
Features: Laboratory grade, high accuracy, high
stability, low zero resistance, low temperature coefficient, suitable
for RTD simulation. |
|
HARS-L
Type: Lab/cal grade
Basic Accuracy: 25 ppm + 0.5
mΩ absolute
Range: 10 mΩ-120 MΩ
Max. Resolution: 1 mΩ,
20 uΩ
Features: Laboratory grade, high accuracy, high
stability, low zero resistance, low temperature coefficient, suitable
for RTD simulation. |
|
HARS-LX
Type: Lab/cal grade
Basic Accuracy: 20 ppm + 0.5
mΩ absolute
Range: 10 mΩ -120 MΩ
Max. Resolution: 1 mΩ,
20 uΩ
Features: Laboratory grade, high accuracy, high
stability, low zero resistance, low temperature coefficient, suitable
for RTD simulation. |
|
HRRS
Type: High resistance High voltage
Basic Accuracy: 0.01% - 1%
Range: 0 - 10 TΩ
Max. Resolution: 10 Ω
Features: High resistance |
|
HRRS-5kV
Type: High power
Basic Accuracy: 0.01% - 1%
Range: 0 - 10 TΩ
Max. Resolution: 10 Ω
Features: High resistance to 5 kV |
|
HPRS
Type: High power
Basic Accuracy: 0.5% - 1%
Range: 0 - 10 MΩ
Max. Resolution: 1 mΩ
Features: High power; 25 W/step; 250 W max. |
|
PRS
Type: Programmable
Basic Accuracy: 0.01% - 1%
Range: 0 - 100 MΩ
Max. Resolution: 1 mΩ
Features: IEEE-488 or RS-232
|
|
HATS-LR
Type: Transfer standard
Basic Accuracy: 1 ppm transfer
Range: 1 Ohms - 100 kΩ/step
Max. Resolution: 1 Ω
Features: High accuracy transfer standard |
|
HATS-Y
Type: Transfer standard
Basic Accuracy: 2ppm transfer
Range: 100 kΩ - 10 MΩ/step
Max. Resolution: 100 kΩ
Features: High accuracy transfer standard |
|
KVD-700
Type: Kelvin-Varley voltage divider
Basic Accuracy: 0.1 ppm linearity
Range: 0 to 1100 V
Max. Resolution: 0.1 ppm
Features: Highly accurate for bridge applications
to measure and calibrate voltages, resistance, etc. |
|
KVD-600
Type: Kelvin-Varley voltage divider
Basic Accuracy: 0.5 ppm linearity
Range: 0 to 1100 V
Max. Resolution: 0.1 ppm
Features: Highly accurate for bridge applications
to measure and calibrate voltages, resistance, etc. |
|
KVD-500
Type: Kelvin-Varley voltage divider
Basic Accuracy: 0.05% to 1%
Range: 1 Ω - 100 kΩ
Max. Resolution: 1 ppm
Features: General purpose; economical; thumbwheel
switches. |
|
DP-500
Type: True digital pot
Basic Accuracy: 0.05% - 1%
Range: 0 - 50 MΩ
Max. Resolution: 1 ppm
Features: Suitable as component |