Features:
  • 2 Hz to 2 MHz
  • 20-V contant output, ±2%
  • 0.25% distortion


  Description

The superior characteristics of this oscillator make it an exceptionally useful laboratory signal source.

Constant output over a very wide frequency range facilitates frequency-response measurements.

High resolution dial and exceptional amplitude and frequency stability are important for measurements of filters and narrow-band devices.

Equally useful in 600 ohm and 50-ohm circuits, since distortion is independent of load, even a short circuit.

When phase-locked to a frequency standard, the oscillator can deliver a high-level standard frequency output with adjustable amplitude and low distortion.

A capacitance-tuned, RC Wien-bridge oscillator drives a low-distortion output amplifier, which isolates the oscialltor from the load and delivers a constant voltage behind 600 ohms. All solid-state circuits ensure long, trouble-free life.

A jack is provided for introduction of a synchronizing signal for phase locking or to furnish a signal, independent of the output attenuator setting, to operate a counter, or to synchronize an oscilloscope or another oscillator.




  Models, Options, & Accessories


Model Description List Price Sale Price
1310-9702 1310-B Oscillator - Discontinued - no replacement
1310-9703 Please call or email us for pricing and availability.
1310-9704 Please call or email us for pricing and availability.
Model Accessories List Price Sale Price
1560-9695 Please call or email us for pricing and availability.
0480-9838 Please call or email us for pricing and availability.
0480-9880 Please call or email us for pricing and availability.



  Technical Specifications:

Range
Resolution
Min. Current
Max. Current
Accuracy at full rated current
30kΩ
10µA
100µA
±(0.03%Rdg. +0.02% FS.
3kΩ
100mΩ
100µA
1mA
±(0.03%Rdg. +0.01% FS
300Ω
10mΩ
1mA
10mA
±(0.03%Rdg. +0.01% FS
30Ω
1mΩ
10mA
100mA
±(0.03%Rdg. +0.01% FS
100µΩ
100mA
1A
±(0.03%Rdg. +0.01% FS
200mΩ
10µΩ
1A
10A
±(0.03%Rdg. +0.01% FS
30mΩ
1µΩ
1A
10A
±(0.03%Rdg. +0.01% FS
3mΩ
100nΩ
1A
10A
±(0.03%Rdg. +0.02% FS.
LOM-DO5000: Open circuit voltage = 5 Vdc
LOM-DO5001: Open circuit voltage = 3 Vdc

Range
Resolution
Min. Current
Max. Current
Accuracy at full rated current
30kΩ
10µA
100µA
±(0.03%Rdg. +0.02% FS.
3kΩ
100mΩ
100µA
1mA
±(0.03%Rdg. +0.01% FS
300Ω
10mΩ
1mA
10mA
±(0.03%Rdg. +0.01% FS
30Ω
1mΩ
10mA
100mA
±(0.03%Rdg. +0.01% FS
100µΩ
10mA
100mA
±(0.03%Rdg. +0.01% FS
200mΩ
10µΩ
10mA
100mA
±(0.03%Rdg. +0.01% FS
Note: The 2 lowest ranges of the standard DO5000 are deleted in this model
Open circuitvoltage = 5 V dc with Limit options for 20mV and 50mV

Wide Measuring Range The long scale length 30,000 count combined with its wide memory range enables the DO5000 to tackle the most demanding tasks with ease. The resolution is 0.1µΩ on the lowest range and the maximum reading is 30,000Ω.
Programmable Measuring Current The measuring current is a maximum 10 Amps on the lowest ranges and may be programmed between 10 and 100% in 1% steps. This ensures that whatever specification you are testing, the DO5000 can be configured to your requirements.
Programmable Hi/Lo Limits Hi/Lo limits may be set audible (beeper) and visual (red/green panel lamps) indicating if the measured values are outside the limits. In addition if one of the interfaces is fitted a signal is available to control other equipment.
Automatic Temperature Compensation Automatically compensates the measured resistance value for temperature, referencing the value to 20°C, particularly useful when measuring materials which have a relatively high temperature coefficient.
Digital Calibration The claibration of the DO5000 is all digital with no need to open the instrument. All adjustments are made via the front panel keyboard ensuring low cost of ownership. The calibration is protected with a password and the date of the last calibration is recorded.
Data Logging The DO5000 has the ability to store up to 4000 readings with date and time stamp. From the stored values max, min and average values may be displayed together with a calculation of the standard deviation.
High Accuracy Large LCD Display The measuring accuracy ±0.03% ensures the highest quality of measurement.
Measuring Current The measuring current may be selected for forward (+1), reverse (-1) or auto average mode which automatically switches the current and displays the average reading. This further enhances the measurement accuracy and reliability eliminating errors due to thermal emf.
Fast Measuring Mode The normla measuring speed is approximately 2 measurements/second, for automated testing where speed is important, a FAST mode is available which measures at 50 measurements/second, ideal for production lines.
Open Circuit Voltage Limit To comply with some testing standards for switches it is possible to limit the open circuit voltage to 20 or 50 mV
Interface Options For those wishing to automate their resistance measurements three interfaces are available. The RS232 and IEEE-488 interfaces are fully talk/listen and generally conform to the SCPI standard. The PLC interface carries all the connectors required to perform measurements and include potential free relay contacts for limit pass/fail and analogue output.
Ohms/Length and Length Feature This feature provides the ability to input the length of a cable and using the measured resistance, display the resistance per length (Ω/1). The length of a cable can also be displayed.


Frequency Range: 2 Hz to 2 MHz in 6 decade ranges. Overlap between ranges, 5%
Accuracy ±3% of setting
Stability (typical at 1 kHz); Warmup drift, 0.1%. After warmup: 0.003% short term (10 min), 0.03% long term (12 h).
Controls Continuously adjustable main dial covers decade range in 305°, vernier in 4 turns.
Synchronization Frequency can be locked to external signal. Lock range ±3% per volt rms input up to 10 V. Frequency dial functions as phase adjustment.
Output Voltage 20 V open circuit, nominal
Power >160 mW into 600Ω
Output Impedance 600Ω. One terminal grounded
Attenuation Continuously adjustable attenuator with >46-dB range.
Distortion <0.25%, 50 Hz to 50 kHz with any linear load. Oscillator will drive a short circuit without clipping.
Hum <0.02%, independent of attenuator setting.
Amplitude vs. Frequency ±2%, 20 Hz to 200 kHz, into open circuit or 600Ω load.
Synchronization Constant-amplitude (0.8 V), high-impedance (27 kΩ) output to drive counter or oscilloscope.
Terminals Output, GR 938 Binding Posts; sync, side panel telephone jack
Available 1560-P95 Adaptor Cable (telephone plug to double plug)
0480-9838 Set to rackmount 1310 alone
0480-9880 Set to rackmount 1310 side by side with same-size instrument such as the 1309 Oscillator, 1369 Tone-Burst Generator, or 1232 Amplifier-Detector
Power 105 to 125, 195 to 235, or 210 to 250 V, 50 to 400 Hz, 12 W
Mechanical Convertible-bench cabinet
Dimensions (WxHxD) 8 x 6 x 8.13 in.
204 x 153 x 207 mm
Weight 7.75lb (3.6 kg) net, 10 lb (4.6 kg) shipping



   
  Welcome | Companies | Search by Type | How To Order | Leasing | About Us  
  Tequipment.NET
205 Westwood Ave
Long Branch, NJ 07740
For our Electronic Whiteboard division visit www.touchboards.com
BBBOnline Reliability Seal. Tequipment.NET
Phone: 1-877-742-TEST (8378) / 732-222-7077
Fax: (732) 222-7088
E-mail: salesteam@Tequipment.NET