Features:
- Certify IR pyrometers from –30°C to 500°C (–22°F to 932°F)
- Large 2.25" (57 mm) blackbody target
- RTD reference well for high precision
- Small, compact design
- We ship Hart Scientific products only within the United States and United States territories. This DOES include US military working abroad. If you have any questions about this policy please call - 1-877-742-8378.
|
Description
For IR calibrations above normal ambient, the 9132 provides a stable blackbody target up to 500°C (932°F). With accuracy to ±0.5°C and stability to ±0.1°C, this new portable IR unit can certify most handheld pyrometers.
Short heating and cooling times mean you won’t have to wait long to get your work done. From room temperature to 500°C the 9132 will be stable within 30 minutes. You won’t find a more compact IR calibrator.
Whether you’re using in-line or handheld infrared pyrometers, you need good calibration standards to verify their accuracy. Our new portable IR calibrators provide stable blackbody targets for calibrating noncontact IR thermometers from –30°C to 500°C.
These new units feature a large, temperature controlled blackbody target with a diameter of 2.25" (57 mm), which offers a large field of view area for optical variations in infrared thermometers. The emissivity of the isothermal target is set at 0.95 (±0.02%), and the target temperature can be controlled in set-point increments of 0.1° from –30°C to 500°C.
For even higher precision, a well is located directly behind the blackbody surface for contact calibration of the blackbody.
These units are as easy to use as “point and shoot.” Simply set the desired blackbody temperature from the convenient front panel control buttons, wait a few minutes for equilibrium, and point the gun at the target. The radiated energy from the blackbody is measured by your IR thermometer. Simply compare its reading to the display on the blackbody and record the difference.
|
Models, Options, & Accessories
| Model |
Description |
List Price |
Sale Price |
| 9132 |
Calibrator, 50-500C IR |
| $2915.00 |  |
|
| 9133 |
Calibrator, -30-150C IR |
| $4125.00 |  |
|
Specifications
| |
9132 |
9133 |
| Temperature Range |
50°C to 500°C (122°F to 932°F) |
–30°C to 150°C at 23°C ambient
(–22°F to 302°F at 73°F ambient) |
| Accuracy |
±0.5°C at 100°C (±0.9°F at 212°F)
±0.8°C at 500°C
(±1.4°F at 932°F) |
±0.4°C
(±0.72°F) |
| Stability |
±0.1°C at 100°C (±0.18°F at 212°F)
±0.3°C at 500°C
(±0.54°F at 932°F) |
±0.1°C
(±0.18°F) |
| Target Size |
2.25" (57 mm) |
| Target Emissivity |
0.95 (±0.02 from 8 to 14 mm) |
| Resolution |
0.1° |
| Heating Time |
30 minutes (50°C to 500°C) |
15 minutes (25°C to 150°C) |
| Cooling Time |
30 minutes (500°C to 100°C) |
15 minutes (25°C to –20°C) |
| Computer Interface |
RS-232 included with 9930 Interface-it software |
| Power |
115 VAC (±10%), 3 A or
230 VAC (±10%),
1.5 A, switchable,
50/60 Hz, 340 W |
115 VAC (±10%), 1.5 A, or
230 VAC (±10%),
1.0 A, switchable,
50/60 Hz, 200 W |
| Size |
4" H x 6" W x 7" D
(102 x 152 x 178 mm) |
6" H x 11.25" W x 10.5" D
(152 x 286 x 267 mm) |
| Weight |
4 lb. (1.8 kg) |
10 lb. (4.6 kg) |
| NIST-Traceable Contact Calibration |
Data at 50°C, 100°C, 200°C, 250°C, 300°C, 400°C, and 500°C |