Our agents are available:
9:00 AM - 6:00 PM EST
Global Specialties 5003 Frequency Counter
   Search: HACKER SAFE certified sites prevent over 99.9% of hacker crime.
   
   
   



Global Specialties 5003 Frequency Counter




Model 5003
Click image to enlarge

Features:
  • 5Hz to 1300MHz Frequency Range
  • Very High Sensitivity at all Frequencies
  • Frequency and Period Measurement, 0.001mHz Resolution
  • Reciprocal Counting Technique Gives Superior Accuracy
  • Push-to-Measure Function with Auto Power-down
  • Large 8 Digit Display with Full Range of Indicators
A hand-held counter with bench top performance, the Model 5003 is a highly compact battery powered frequency counter which offers the convenience of a hand-held multimeter. Its performance exceeds that of many bench top counters of much higher cost.
A large and clear display:
Despite its compact dimensions, the Model 5003 incorporates an 8 digit liquid display crystal of the size you?d expect to find on a bench top instrument. A full range of indicators provide indication of measurement function, measurement time, overflow, trigger activity, low battery, and the measurement units. Operation is simple with all functions and ranges selected using just five large buttons.
Wide frequency range and high sensitivity:
The Model 5003 can measure frequencies in the range 5Hz to 1300 MHz. Unlike many counters, the sensitivity is high across the whole frequency range with no dead spots. A low pass filter can be selected to reduce high frequency signal noise and ensure stable readings at lower frequencies.
Low power consumption and push-to-measure:
Model 5003 has a remarkably low power consumption enabling it to operate for many hours from a standard 9V battery. Alternatively it can be operated using a AC adapter. A push-to-measure capability gives a virtually instantaneous reading followed by an automatic power down after 15 seconds. This provides greatly extended battery life where continuous monitoring of the signal is not required.
Reciprocal counting for improved resolution:
The Model 5003 uses a reciprocal frequency counting technique which involves multiple period measurements followed by computation of the reciprocal. The system, yields at least 7 digits of resolution per second of measurement time and can measure low frequencies to a resolution of 0.0001mHz
Frequency and period measurement:
The Model 5003 can display signals in tenths of period as an alternative to frequencies to 25MHz.
Hold Function:
A hold button allows readings to be frozen on the display for measuring non-continuous signals or recording results later.


Model Description List Price Sale Price
5003 1.3GHz Handheld Frequency Counter, Part #: 105-5003 - Discontinued - no replacement

     Specifications:
MEASUREMENT FUNCTIONS:
Frequency (Range A)
Frequency Range: 5Hz to 25 MHZ
Resolution: 10-7Hz to 10Hz (see Note)
Accuracy: +(1 digit + timebase error)

Frequency (Range B)
Frequency Range: 20MHz to 1.3GHZ
Resolution: 1Hz to 1kHz (see Note)
Accuracy: +(1 digit + timebase error)

Period
Frequency Range: 5Hz to 25 MHZ
Resolution: 10-7ns to 1 µs (see note)
Accuracy: +(1 digit + timebase error)

NOTE: The resolution depends upon the measurement time and the input frequency. At least 7 digits are displayed per second of measurement time. Measurement time is selectable to be 0.1, 1, or 10 seconds.
INPUT SPECIFICATIONS:
Input A
Input Impedance: 1MOhm//25pF
Frequency Range: 5Hz to 25MHz
Sensitivity: Sinewave 15mVrms 10Hz- 20MHz
Max. Permissible Input Voltage: 200Vdc; 250Vrms 50Hz to 400Hz reducing to Vrms above 1Mhz

Input B
Input Impedance: 50MOhm nominal
Frequency Range: 20MHz to 1.3GHz
Sensitivity: 10mVrms 20MHz-7000MHz, 50mVrms to 1.3GHz
Max. Permissible Input Voltage: 250Vdc; 250Vrms 50Hz to 400Hz, 1Vrms 20MHz to 1.3GHz

Signal activity Indicator
When an adequate input signal is present the Trig indicator will show, indicating that a measurement is possible.

Noise Filter
For input A, a low pass filter with a cut-off frequency of 50kHz is user selectable to ensure stable readings at low frequencies.
OPERATING FUNCTIONS:
Press to measure
With the power switch off, pressing any of the function select keys will power the instrument up in the corresponding function. The instrument will automatically switch off 15 seconds after the key is released.
OPERATING FUNCTIONS:
Hold
Pressing the Hold key will stop further measurements being made and the current measured value will remain in the display, with the Hold indicator on, until the Hold key is pressed again.
TIMEBASE:
Initial Error: +2ppm (10MHz crystal)
Temperature: Typically < + 0.3ppm/°C
Coefficient: for 18°C to 28°C and +10ppm for-20°C to 70°C
Ageing Rate: +5ppm/year
POWER REQUIREMENTS:
Battery Type: 9V Alkaline
Battery Life: Typically 12 hours continuous or 3000 press-to-measure operations. Low battery indicator.
External Input: 6V-12V DC from approved AC adapter or ther DC source
GENERAL:
Operating Range: +5°C to +40°C, 20% to 80% RH
Storage Range: -20°C to +60°C
Size: 3.2"x7"x1.2" (WxLxD)
Weight: 7 oz. (Less Battery)
DISPLAY:
No. of Digits: 8
Size of Digits: .45" High
Indicators: 15 indicators

        OPTIONS Carrying Case 111-0110


   
  Welcome | Companies | Search by Type | How To Order | Leasing | About Us  
  Tequipment.NET
205 Westwood Ave
Long Branch, NJ 07740
For our Electronic Whiteboard division visit www.touchboards.com
BBBOnline Reliability Seal. Tequipment.NET
Phone: 1-877-742-TEST (8378) / 732-222-7077
Fax: (732) 222-7088
E-mail: salesteam@Tequipment.NET