Global Specialties 5002 Frequency Counter
   Search: HACKER SAFE certified sites prevent over 99.9% of hacker crime.
   
   
   



Global Specialties 5002 Frequency Counter




Model 5002
         Click image to enlarge

Features:
  • 100KHz to 110MHz RF Generator with AM and FM Capability
  • Frequency, period, ratio, pulse width, and count modes
  • High resolution reciprocal measurement
  • 1.3 GHz maximum frequency
  • AC or battery operation
  • Portable with detachable AC line cord
  • Selectable gate time 0.1, 1, 10 seconds
  • Trigger level control and low pass filter
  • External standard input with auto-change over
The Model 5002 is an intelligent bench-top 1.3GHz universal counter-timer. The unit combines Global's renowned frequency counter experience with the latest microprocessor technology to bring outstanding value and performance.

Key Features
The Model 5002 features a frequency range of 5Hz to 1.3 GHz, and measurement functions including frequency, time interval, period, ratio, pulse width and event counting. Unique to the 5002, the unit becomes portable by removing the AC line cord and inserting either Alkaline or Nicad batteries. There is a built in trickle charge circuit for use with Nicads, via the selector switch. The unit has gate times of 0.1, 1, and 10 seconds and uses a high resolution reciprocal measurement technique giving 7 significant digits of accuracy. The LCD read-out displays the measurement values and operating modes. Trigger level control and a low pass filter are provided standard along with both internal and external timebase input capabilities. The external timebase input contains a unique automatic detector and change-over whenever a signal is present.

Applications
The Model 5002 makes an excellent addition to any electronic laboratory. The wide frequency range makes it suitable for audio testing or cellular telephone and CATV repair work. The multiple measurement functions expand its application into R&D and educational areas.


Model Description List Price Sale Price
5002 1.3GHz Maximum Frequency Universal Counter-Timer, Part #: 105-5002 - Discontinued - suggested replacement: Instek GFC-8131H

     Specifications:

       Inputs:
Input A:
Impedance: 1 M‡ @ 25 pF
Freq. range: 5Hz...25MHz
Sensitivity: Sinewave 32mVrms 10Hz to 20MHz; pulse 40mV pk-pk 5Hz to 14MHz
Trigger Level: Continuously adjustable by front panel control.
Max. Permissible Input Voltage: 200VDC; 250Vrms 50/60Hz reducing to 1Vrms above 1MHz
Low Pass Filter: Switchable 50kHz low pass noise filter
Coupling: AC
Input B:
Impedance: 50 ‡ nominal
Freq. range: 20MHz to 1.3GHz
Sensitivity: 14mVrms 20MHz...500MHz; <50mVrms to 1.3GHz
Max. Permissible Input Voltage: 250VDC; 250Vrms 50/60Hz, 1Vrms
Input Voltage: 20MHz to 1.3GHz
Coupling: AC


       Functions: Frequency
Input A:
Range: 5Hz to 25MHz
L.S.D. Displayed: 100Hz to 1-7Hz depending on measurement time and input frequency. At least 7 digits displayed per second of measurement time.
Input B:
Range: 20MHz to 1.3GHz
L.S.D. Displayed: 1Hz to 10kHz depending on measurement time and input frequency. At least 7 digits displayed per second of measurement time.
Period (Input A only):
Frequency Range: 5Hz to 25MHz
L.S.D. Displayed: 10-7ns to 1µs depending on measurement time and input frequency. At least 7 digits displayed per second of measurement time.
Count (Input A only):
Counter Range: 1 to 268435456 (228): only the least significant 8 digits shown with overflow indication past 99999999 pulses.
Freq. Range: 1Hz to at least 14MHz
Minimum Pulse Width: 20ns
Ratio A/B:
Freq. Range: A: 5Hz to 25MHz B: 20MHz to 1.3GHz
L.S.D. Displayed: The answer is displayed with 8 significant digits irrespective of actual input frequencies and measurement time.
Pulse Width (Input A only):
Mode: Falling to rising edge or rising to falling edge
Pulse Width Range: 26s...1µs
Resolution: 100ns
Measurement Time: 0.1s and 1s ranges determine the inter measurement time. 10s range will hold until reset


       Timebase:
Internal Standard:
Crystal Oscillatory Frequency: 10MHz
Initial Oscillatory Adjustment Error: ±1ppm @ 23°C
Oscillator Temperature Coefficient: Typically less than ±0.3ppm/°C 18°C to 28°C±10ppm -20°C to 70°C
Oscillator Aging Rate: <±5ppm/year
External Standard:
Input Frequency: 10MHz
External Standard Selection: Front panel socket for external 10MHz standard input with automatic detection and change-over
Sensitivity: TTL/CMOS compatible (typically 2V pk-pk), AC coupled
Max. Input Voltage: 5Vrms, 50VDC


Power Requirements:
110/120 Volts AC nominal or 220/240 volts AC nominal, adjustable internally. The instrument will operate safely and meet specification within normal AC supply variations viz. 99-132 Volts AC and 198-264 Volts AC respectively 6 ³C² size Alkaline or Nicad Batteries
Cell Voltage: 1.2-1.5VDC Nominal
* Batteries Not Included
Power consumption: 8VA max.
General:
Environmental Operating Range: +5°C to +40°C, 20% to 80% RH
Environmental Storage Range: -20°C to +60°C
Size: 4²H x 10²W x 7²D
Weight: 3 lbs. without Batteries

        Options: Communications Interface


   
  Welcome | Companies | Search by Type | How To Order | Leasing | About Us  
  Tequipment.NET
205 Westwood Ave
Long Branch, NJ 07740
For our Electronic Whiteboard division visit www.touchboards.com
BBBOnline Reliability Seal. Tequipment.NET
Phone: 1-877-742-TEST (8378) / 732-222-7077
Fax: (732) 222-7088
E-mail: salesteam@Tequipment.NET