DUAL SECTION: Output Voltage 1&2
Load Current 1&2 |
1.3-20VDC (cont. var.)
.25A max |
| Constant Voltage Mode |
NO |
Line Regulation
Load Regulation
Ripple & Noise |
0.25%
0.1%
10mV rms max |
| Constant Current Mode |
NO |
Line Regulation
Load Regulation
Ripple & Noise |
n/a
n/a
n/a |
METERING:
Meter Selection
Meter Accuracy:
Overload Protection: |
1 digital DPM provided for O/P1 & O/P2
Switch selection for voltage or current monitoring
±0.5% of rdg. ±1 digit
All supplies current limited (external short will not damage power supplies) |
5V SECTION: Output Voltage
Output Current
Ripple & Noise |
5VDC (±0.25V) fixed
1.0A max, current limited
10mV max |
GENERAL: Operating Temp
Input Voltage
Weight
Dimensions |
0 to 40°C
110-120VAC@60Hz or 220-240VAC@50Hz
6 lbs. (2.7kg) max
10"W x 7"D x 3"H |
PART NUMBER: (110V input)
(220V input) |
105-1310
105-1312 |