Two Identical Sections:
Output Voltage: 0-32VDC continuously variable
Load Current: 0-5 A max. continuously variable
|
Metering:
Independent 3 digit DPMs for monitoring output voltage and load current of each section
Meter Accuracy: ± 3 counts
|
Constant Voltage Mode Operation:
Line Regulation: Less than ± 0.01% + 2mV (±10% line change)
Load Regulation: Less than ± 0.01% + 2mV (no load to full load)
Ripple & Noise: Less than 1mVrms max (20Hz-20MHz)
|
Constant Current Mode Operation:
Line Regulation: Less than ± 0.1% ± 250µA (±10% line change)
Load Regulation: Less than ± 0.1% + 250µA (no load to full load)
Ripple & Noise: 0.04% rms max (2.0mA)
|
Overload Protection:
Automatic overload and short circuit protection
|
General:
Operating Temperature: 0 to 40°C
Input Voltage: 115V or 230VAC, 60Hz (with Internal Tap Selector)
Dimensions: (WxDxH) 16.5" x 11.8" x 5.2"
Weight: 33.4 lbs
|
|
Click here to download the Spec Sheet in PDF format
|