Detailed specifications
Temperature
Temperature measurement range (not calibrated below -10 °C) -20 °C to +350 °C (-4 °F to + 662 °F) (two ranges)
Accuracy ± 2 °C or 2 % (whichever is greater)
On-screen emissivity correction Yes
Imaging performance
Field of view 23° x 17°
Spatial resolution (IFOV) 2.5 mRad
Minimum focus distance Thermal lens: 15 cm (6 in)
Visible (visual) light lens 46 cm (18 in)
Focus Manual
Image frequency 9 Hz refresh rate
Detector type 160 X 120 focal plane array, uncooled microbolometer
Infrared lens type 20 mm F = 0.8 lens
Thermal sensitivity (NETD) ≤ 0.1 °C at 30 °C (100 mK)
Infrared spectral band 7.5 μm to 14 μm
Visual camera 640 x 480 resolution
Image presentation
Palettes Ironbow, blue-red, high contrast, amber, hot metal, grey
Level and span Smooth auto-scaling and manual scaling of level and span
Minimum span (in manual mode) 2.5 °C (4.5 °F)
Minimum span (in auto mode) 5 °C (9 °F)
IR-Fusion® information Full infrared with MAX, MID, or MIN automatic blending; and picture-in-picture with MAX, MID, or MIN automatic blending (Visual and IR blending)
Picture-In-Picture (PIP) Three levels of on-screen IR blending displayed in center 320 x 240 pixels
Full screen (PIP off) Three levels of on-screen IR blending displayed in center 640 x 480 LCD
Voice annotation
Voice annotation 60 seconds maximum recording time per image
Image and data storage
Storage medium SD memory card (2 GB memory card will store at least 1200 fully radiometric (.is2) IR and linked visual images each or 3000 basic (.bmp) IR images)
File formats Non-radiometric (.bmp) or fully-radiometric (.is2)
No analysis software required for non-radiometric (.bmp) files
Export file formats w/SmartView™ software JPEG, BMP, GIF, PNG, TIFF, WMF, EXIF, and EMF

General specifications
Temperature Operating:-10 °C to 50 °C (14 °F to 122 °F)
Storage:-20 °C to +50 °C (-4 °F to 122 °F) without batteries
Relative humidity 10 % to 90 % non-condensing
Display 9.1 cm (3.6 in) diagonal landscape color VGA (640 x 480) LCD with backlight (selectable bright or auto)
Controls and adjustments User selectable temperature scale (°C/°F)
Language selection
Time/Date set
Software SmartView™ full analysis and reporting software included
Power Battery: Internal rechargeable battery pack (included)

Battery life
Three to four hours continuous use (assumes 50 % brightness of LCD)
Battery charge time using ac adapter/charger and dc car charger: Two hours for full charge
AC operation/charging AC adapter/charger (110 Vac to 220 Vac, 50 Hz to 60 Hz). Charges battery while imager is operating. Universal ac mains adapters included.
Power saving Sleep mode activated after 5 minutes of inactivity, automatic power off after 20 minutes of inactivity
Safety standards CE Directive: IEC/EN 61010-1 2nd Edition Pollution Degree 2
Electromagnetic compatibility EMC directive: EN61326-1
C-Tick: IEC/EN 61326
US FCC: CFR 47, Part 15 Class A
Vibration 2 G, IEC 68-2-29
Shock 25 G, IEC 68-2-29 {2 m (6.5 ft) drop, 5 sides}
Dimensions (HxWxL) 0.27 m x 0.13 m x 0.15 m (10.5 in x 5 in x 6 in)
Weight 1.2 kg (2.65 lb)
IP rating IP54
Warranty Two-years
Calibration cycle Two-years (assumes normal operation and normal aging)
Supported languages English, Italian, German, Spanish, French, Russian, Portuguese, Swedish, Turkish, Czech, Polish, Finnish, Simplified Chinese, Traditional Chinese, Korean, and Japanese

Ti10 -Vs- Ti25
To Compare Other Models Please Visit The Interactive Selection Guide.
  Fluke Ti10 Fluke Ti25
Imaging Performance
Thermal: Field of View (FOV) 23° horizontal x 17° vertical
Minimum focus distance Thermal lens: 15 cm (approx. 6 in), Visible (visual) light lens: 46 cm (approx. 18 in)
Thermal sensitivity (NETD) ≤ 0.1 °C at 30 °C (100 mK) ≤ 0.2 °C at 30 °C (200 mK)
Minimum span (Auto/Manual) 5 °C/2.5 °C 10 °C/5 °C
Focus Manual
Detector size 160 x 120
Visual: On camera operating modes Picture-in-Picture (Blending is user selectable between MAX, MID and MIN) and full screen IR (Blending is user selectable between MAX, MID and MIN) Full Picture-in-Picture and full screen IR
Visual (Visible light) camera 640 x 480 pixels, full color
Temperature Measurement
Temperature range -20 °C to +350 °C (-4 °F to +662 °F), 2 ranges -20 °C to +250 °C (-4 °F to +482 °F)
Accuracy ± 2 °C or 2 % (whichever is greater) ± 5 °C or 5 % (whichever is greater)
Measurement modes Center point and hot and cold markers Center point
On-screen emissivity correction Yes No
Image presentation
Digital display 9.1 cm (3.6 in) diagonal landscape color VGA (640 x 480) LCD
LCD backlight Selectable bright or auto
Pallettes Ironbow, blue-red, high contrast, amber, hot metal, grey Ironbow, blue-red, high contrast, grey
Image & Data Storage
Fully radiometric Yes
Storage medium 2 GB SD card stores up to 3000 .bmp IR images or 1200 .IS2 IR-Fusion images
File formats supported Exportable to JPEG, BMP, GIF, PNG, TIFF, WMF EXIF, and EMF
Voice memo recorder (voice annotation) Yes No
Software
Included Software SmartView; Full analysis and reporting software
Controls & Adjustments
Set-up controls Date/time,°C/°F, language, emissivity, hot spot and cold spot on image Date/time,°C/°F, language
Language selection English, German, French, Spanish, Portuguese, Italian, Swedish, Finnish, Russian, Czech, Polish,Turkish, Simplified Chinese, Traditional Chinese, Korean, Japanese
Image controls Smooth auto scaling and manual scaling
On-screen indicators Battery status, real time clock and center point temperature, range and span indication and high and low alarm settings
Power
Battery type Internal rechargeable battery (included)
Battery operating time 3 to 4 hours continuous operation
Battery charging 2 hours with ac charger or dc car charger (charges battery while operating)
AC operation AC adapter/charger 110/230 V ac, 50/60 Hz
Power saving Automatic shutdown and sleep modes (user specified)
Enviromental & Mechanical Design
Operating temperature -10 °C to +50 °C (+14 °F to +122 °F)
Storage temperature -20 °C to +50 °C (-4 °F to +122 °F)
Relative humidity Operating and storage 10 % to 90 %, non-condensing
Water and dust resistant IP54
Two meter (6.5 feet) drop test Yes
Protective lens cover Yes
Weight (including battery) 1.2 kg (2.6 lbs)
Imager size (HxWxD) 267 mm x 127 mm x 152 mm (10.5 in x 5.0 in x 6.0 in)
Other
Warranty Two-years
EN 61010-1 2nd edition and EN61326-1 Yes



   
  Welcome | Companies | Search by Type | How To Order | Leasing | About Us  
  Tequipment.NET
205 Westwood Ave
Long Branch, NJ 07740
For our Electronic Whiteboard division visit www.touchboards.com
BBBOnline Reliability Seal. Tequipment.NET
Phone: 1-877-742-TEST (8378) / 732-222-7077
Fax: (732) 222-7088
E-mail: salesteam@Tequipment.NET