Fluke T+PRO-1AC KIT Electrical Tester & AC Voltage Detector Kit
Specifications
| Temperature |
Operating: -10 C to 55 C (14 F to 131 F) Storage: -30 C to 60 C (- 22 F to 140 F) |
| Relative humidity |
0 C to 30 C (3 F to 86 F): 90 % 30 C to 40 C (86 F to 104 F): 75 % 40 C to 50 C (104 F to 1 F): 45 % |
| Altitude |
Operating: 2,000 m (approx. 6,561.6 ft Storage: 10,000 m (approx. 3 ,808.4 ft) |
| Battery type/life |
AAA (2); 40 hours |
| Shock, vibration |
Sinusoidal vibration per MIL-PRF- 8800F for a Class instrument |
| Safety |
ISA-8 .0 .01 (IEC 61010-1 Mod) Second Edition, CAN/CSA-C . No. 61010-1 Second Edition, IEC 61010 - 1 to 1000 V CAT III/600 V CAT IV Compliance to NFPA 70E1 |
| AC Bandwidth |
45 Hz to 66 Hz |
| Maximum working voltage |
1000 V ac/dc |
| Maximum measurable voltage |
600 V ac/dc |
| Duty cycle |
Indefinitely for voltages up to 240 V. For voltages between 40 V and 600 V the duty cycle is 30 s on / 300 s off. For voltages above 40 V the tester must connect to a voltage source only for a MAXIMUM of 30 s and then disconnect for a MINIMUM of 300 s. |
| Voltage hazard LED |
LEDs turn on at voltages > 30 V ac/dc + 35 % |
| LED voltage indication levels |
1 V, 4 V, 48 V, 1 0 V, 08 V, 40 V, 77 V, 480 V, 600 V |
| LED voltage indication levels for Canadian version |
1 V, 4 V, 48 V, 1 0 V, 08 V, 40 V, 347 V, 480 V, 600 V |
| LEDs |
LEDs turn on between 70 % and 85 % of the indicated voltage on the LED, except for the 1 V LED which turns on between 50 % and 100 %. |
| Accuracy |
AC voltage: + (3 % rdg + digits) DC voltage: + (2 % rdg + digits) Resistance: + (5 % rdg + 3 digits) |
| LCD Resolution |
0.1 V for voltages < 50 V, 1 V for voltages > 50 V 0.01 k ¸ for resistance measurement (For T+PRO Only) |
| GFCI Test current |
100 V - 00 V at 0 mA - 35 mA for 1 s |
| Standard input test current |
< 5 mA |
| Size (HxWxL) |
1.3 in x .15 in x 7.6 in (3.3 cm x 5.46 cm x 19.3 cm ) |
| Weight |
9.9 oz (0.28 kg) |
| Operating principle |
Senses the steady state electrostatic ?eld produced by ac voltage through insulation without requiring contact to the bare conductor. A red glow at the tip and a beeping noise (if not switched OFF) indicates the presence of voltage. |
| Voltage sensing ranges |
Nominally, 90 V AC to 1000 V AC or 200 V AC to 1000 V AC depending on model, 45 Hz to 405 Hz; also a 20 V to 90 V control circuit model |
| Detector tip style |
Blade or round, depending on model |
| Light source |
One high intensity red LED |
| Agency Approvals |
c CSA us, CE, TUV, C-Tick |
| Safety Rating |
1000 V, CAT IV |
| IP Rating |
IP 40 |
| Operating temperature |
-10 °C to 50 °C |
| Operating humidity ranges |
0 % to 95 % (0 °C to 30 °C) 0 % to 75 % (30 °C to 40 °C) 0 % to 45 % (40 °C to 55 °C) |
| Operating Altitude |
3000 meters |
| Batteries |
2 AAA alkaline batteries included |
|