Fluke Saturn Geo X Advanced 3 & 4 Pole Earth Ground Tester
Specifications
| Technical Data |
| Display |
4-digit (2999), 7-segmentliquid crystal display, 18 mm high, with fluorescent and active illumination (GEO X) |
| Working temperature |
-10° C ... + 50° C |
| Operating temperature |
0° C ... + 35° C |
| Reference temperature |
+18° C ... +28° C |
| Storage temperature |
-30° C ...+60° C |
| Operating error |
refers to operating temperature range |
| Intrinsic error |
refers to reference temperature range |
| Climatic class |
JWG as per DIN 40040 |
| Protective type |
IP 56 as per DIN 40050 |
| Operating altitude |
max. 2000 m |
| Safety |
Safety class II ( ) as per IEC/EN 61010-1 |
| Max. noise voltage |
24 V, thereon measurements are locked |
| Power supply |
6 x 1.5 V alkali-mangan batteries (IEC LR 6) or 1.5 V zink-carbon-batteries (IEC R 6) or 1,2 V accus |
| Dimensions |
240 x 180 x 110 mm (L x W x H) |
| Weight |
approx. 1.5 kg incl. batteries approx. 5.9 kg incl. 4 pcs. batteries and accessories in carrying case |
| Warranty |
2 years |
| Calibration interval |
3 years, recomended |
|