| Technical Data |
| Inputs |
Number: 4 voltage and current (3 phases + neutral)
Maximum voltage: 1000 Vrms (6 kV peak)
Maximum sampling speed: 200 kS/s on each channel simultaneously
|
| Volt/Amps/Hertz |
Vrms (AC + DC)
Measurement range: 1 ... 1000 V
Accuracy: 0.5% of Vnom
Vpeak
Measurement range: 1 ... 1400 V
Accuracy: 5% of Vnom
Crest factor
Measurement range: 1.0 ... > 2.8
Accuracy: ±5%
Arms (AC + DC)
Measurement range: 0 ... 20 kA
Accuracy: ±1% ± 5 counts
Apeak
Measurement range: 0 ... 5.5 kA
Accuracy: 5%
Crest factor
Measurement range: 1 ... 10
Accuracy: ±5%
Hz (60 Hz nominal)
Measurement range: 51.00 ... 69.00 Hz
Accuracy: ±1% ± 5 counts
|
| Dips and swells |
Vrms (AC+DC) ³
Measurement range: 0.0% … 100% of Vnom
Accuracy: ±1% of Vnom
Arms (AC+DC) ³
Measurement range: 0 ... 20 kA
Accuracy: ±1% ± 5 counts
|
| Harmonics |
Harmonic (interharmonic) (n)
Measurement range: DC, 1..50; (Off, 1..49) measured relative to fundamental or to total rms
Vrms
Measurement range: 0.0 … 1000 V
Accuracy: ±5% ± 2 counts
Arms
Measurement range: 0.0 … 4000 mV x clamp scaling
Accuracy: ±5% ± 5 counts
Watts
Measurement range: Depends on clamp scaling
Accuracy: ±5% ± n x 2% or reading, ± 10 counts
DC voltage
Measurement range: 0.0 … 1000 V
Accuracy: ±5% ± 10 counts
THD
Measurement range: 0.0 … 100.0%
Accuracy: ±2.5%
Hz
Measurement range: 0 … 3500 Hz
Accuracy: ± 1 Hz
Phase angle
Measurement range: -360° ... +360°
Accuracy: ± n × 1.5°
|
| Power and energy |
Watt, VA, VAR
Measurement range: 1.0 … 20.00 MVA¹
Accuracy: ±1.5% ± 10 counts
kWh, kVAh, kVARh
Measurement range: 00.00 …200.0 GVAh¹
Accuracy: ± 1.5% ± 10 counts
Power Factor/ Cos φ / DPF
Measurement range: 0…1
Accuracy: ± 0.03
|
| Flicker |
Pst (1 min), Pst, Plt, PF5
Measurement range: 0.00 … 20.00
Accuracy: ±5%
|
| Unbalance |
Volts
Measurement range: 0.0 … 5.0%
Accuracy: ±0.5%
Current
Measurement range: 0.0 … 20%
Accuracy: ± 1%
|
| Transient Capture |
Volts
Measurement range: ±6000 V
Accuracy: ±2.5% of Vrms
Minimum detect duration: 5 μs (200kS/s sampling)
|
| Inrush mode |
Arms (AC+DC)
Measurement range: 0.000 … 20.00 kA¹
Accuracy: ±1% of meas ± 5 counts
|
| Autotrend recording |
Sampling: Up to 100 readings/s continuous sampling per channel
Memory: Up to 3600 min, max and avg points for each reading
Recording time: Up to 450 days
Zoom: Up to 12x horizontal zoom
|
| Memory |
Screens: Fluke 434 - 50; Fluke 433 - 25
Data sets including recordings: Fluke 434 - 10; Fluke 433 - 5
|
| Notes |
¹ Depending on clamp scaling
² 50 Hz/60 Hz nominal frequency according to IEC 61000-4-30
³ Value is measured over 1 cycle, commencing at a fundamental zero crossing, and refreshed each half-cycle
|