Fluke PR620 LEM Multimeter AC/DC Current Probe
   Search: HACKER SAFE certified sites prevent over 99.9% of hacker crime.
   

   
   




Fluke PR620 LEM Multimeter AC/DC Current Probe




  Specifications

Electrical Characteristics
Current Ranges 60 A and 600 A ACRMS or DC
Measuring Ranges +/- 85 A and +/- 850 A
Output Sensitivity 10 mV/A (60A) 1 mV/A (600 A)
Accuracy (60A range) +/- 1% of reading +/- 0.1 A
Accuracy (600A range) +/- 1% of reading +/- 0.5 A
Resolution +/- 100 mA (60 A and 600 A)
Load Impedance > 10 kOhms and ÷ 100pF
Conductor Position Sensitivity +/- 1% relative to centre reading
Frequency Range (small signal) DC to 10 kHz (- 3 dB)
Temperature Coefficient +/- 0.1% of reading / °C
Power Supply 9 V Alkaline, MN1604/PP3 50 Hours, low battery indicator Selectable : Auto Switch Off 30 minutes typical or continuous
Working Voltage (see Safety Standards section) 600 V ACRMS or DC
General Characteristics
Maximum Conductor Size 35 mm diameter
Output Connection 4mm safety plugs
Output Zero Auto zero via push button
Cable Length 1.5 meters
Operating Temperature Range -10 to +60 °C
Storage Temperature Range.(with battery removed) -20 to +85 °C
Operating Humidity 15% to 85% (non condensing)
Weight 480 g



   