Fluke PR1200ACI LEM Multimeter AC Only Current Probe
Specifications
| Electrical Data |
| Primary nominal current |
1000 ARMS |
| Measuring range |
0.1 A to 1200 A |
| Overload capability, for 1 hr, 33 % duty cycle |
1500 A, 50 / 60 Hz |
| Turns ratio |
1000 / 1 |
| Accuracy at 100 A, 2 kHz |
1% of reading |
| Phase shift at 2 kHz |
1 ° |
| Frequency range |
30 Hz to 10 kHz (-3 dB) |
| General Data |
| Dielectric withstand |
5.5 kV / 50 Hz / 1min |
| Operating temperature |
-10°C to +55°C |
| Storage temperature |
-40°C to +70°C |
| Maximum relative humidity |
85 % |
| Maximum altitude |
2000 m |
| Environment |
Indoor use only |
| Case material |
UL 94 V0 |
| Overall dimensions |
230 x 106 x 44 mm |
| Weight |
650 g |
| Jaw opening |
54 mm |
| Conductor diameter |
54 mm max. or 1 bar 50 x 5 mm |
| Standards |
| Safety |
European Low voltage Directives 72/23/EEC and 93/68/EEC European EMC Directives 89/336/EEC and 93/68/EEC IEC61010-1 : 1993 IEC61010-2-032: 1994 IEC61010-2-031: 1993 600 V RMS or DC, over voltage Cat. III, Pollution degree 2 |
| EMC RF Susceptibility |
EN 50082-1:1992 3V/m Residential, Commercial and Light Industry EMC RF Emissions EN 50081-1: 1992 Residential, Commercial and Light Industry FCC Part 15 Class B |
| Protection |
IP40 with jaws closed IP30 with jaws opened |
|