Our agents are available:
9:00 AM - 6:00 PM EST
Fluke N5K PP52
Power Phase Analyzer
   Search: HACKER SAFE certified sites prevent over 99.9% of hacker crime.
   

   
   




Fluke N5K PP52
Power Phase Analyzer



Fluke N5K PP52
Click image to enlarge

 Fluke N5K PP52

    Announcement


Features
  • 0.3 – 1000 V und 0.06 – 20 A, direct
  • Sampling rate 1/3 MHz
  • Bandwidth DC to 3 MHz
  • Basic accuracy 0.05 % + 0.05 %



  Models, Options, & Accessories


Model Description List Price Sale Price
N5K PP52 EA1520Z, POWER PHASE VOLT/CUR, NORMA 5000 & 4000 $3595.00
$3397.28 
N5K PP50 EA1500Z, POWER PHASE VOLT/CUR, NORMA 4000 & 5000 $3595.00
$3397.28 
N5K PP51 EA1510Z, POWER PHASE VOLT/CUR, NORMA 5000 & 4000 $3395.00
$3208.28 
N5K PP54 EA1540Z, POWER PHASE VOLT/CUR NORMA, 5000 & 4000 $3295.00
$3113.78 



Ranges
Voltage
8 ranges 0.3 – 1 – 3 – 10 – 30 – 100 – 300 – 1000 V
Upeak = 2 x range
Input impedance 2 MOhm / 20 pF
CMR Common Mode Rejection 120 dB at 100 kHz
Current
6 ranges 30 – 100 mA – 0.3 – 1 – 3 – 10 A
Ipeak = 2 x range; max level 150 % at sine wave (limit of error as at 100 %).
Input impedance with integrated shunts
Ranges 30 mA, 100 mA 1 Ohm
Ranges 0.3 A, 1 A 0.1 Ohm
Ranges 3 A, 10 A 0.01 Ohm
Current overload max. 15A continuous
30 A < 5 sec / 15 sec no load
100 A < 0.1s / 30 sec no load
Input for external shunt or probe
BNC terminal 100 kOhm / 30pF
30 – 100 mV – 0.3 – 1 – 3- 10 V
Overload max. 20 Vrms
CMR common mode rejection 120 dB at 100 kHz

Error of Amplitude
Basic accuracy PP50
Sum limit of error U I
Range 0.05% 0.05%
Reading 0.05% 0.05%
Voltage and current depending on the input level at 45 – 65 Hz frequency range
Input level Sum limit of error U Sum limit of error I
in % in % in %
100 0.10 0.10
50 0.15 0.15
30 0.22 0.22
10 .55 .55
5 1.05 1.05
3 1.72 1.72
1 5.05 5.05

PP50 Bandwidth
  U and I via BNC I direct measured
Bandwidth -3dB 10 MHz 1 MHz
Current measurement accuracy depending on the frequency (reading + range)
Frequency Limits of error current [ % ]
[Hz] Internal shunt BNC input
0 0.10 -0.10 0.10 -0.10
10 0.10 -0.10 0.10 -0.10
45 0.10 -0.10 0.10 -0.10
65 0.10 -0.10 0.10 -0.10
500 0.10 -0.10 0.10 -0.10
1000 0.10 -0.10 0.10 -0.10
2000 0.12 -0.19 0.12 -0.16
5000 0.15 -0.31 0.13 -0.24
10000 0.18 -0.40 0.15 -0.30
20000 0.20 -0.49 0.17 -0.46
50000 0.23 -.61 0.18 -0.44
100000 0.25 -.70 0.20 -.50
Voltage measurement accuracy depending on the frequency (reading + range)
Frequency in Hz Limits of error voltage in %
0 0.10 -0.10
10 0.10 -0.10
45 0.10 -0.10
65 0.10 -0.10
500 0.10 -0.10
1000 0.10 -0.10
2000 0.12 -0.16
5000 0.13 -0.24
10000 0.15 -0.30
20000 0.17 -0.36
50000 0.18 -0.44
100000 0.20 -0.50
Valid for averaged values at 23 ±5 °C ambient temperature, sine waveform and after 1 hour turn on time with measuring signal.

Power / Angular Error
PP50 Between U and IBNC Between U and IShunt
Angular Error 0.005° +0.005° / kHz 0.025° +0.015° / kHz
Aliasing filter OFF
Error Power
Frequency in Hz Limit of error power in % at Lamda = 1
45 0.16 -0.16
65 0.16 -0.16



   
  Welcome | Companies | Search by Type | How To Order | Leasing | About Us  