|
Fluke N5K PP50 Power Phase Analyzer

Click image to enlarge
Fluke N5K PP50
|
|
Features
- 0.3 V – 1000 V, 0.03 A – 10 A direct
- Sampling rate 1 MHz
- Bandwidth DC to 10 MHz
- 0.1 % basic accuracy for 2 years
|
Models, Options, & Accessories
| Model |
Description |
List Price |
Sale Price |
| N5K PP50 |
EA1500Z, POWER PHASE VOLT/CUR, NORMA 4000 & 5000 |
$3595.00 |
| $3397.28 |  |
|
| N5K PP51 |
EA1510Z, POWER PHASE VOLT/CUR, NORMA 5000 & 4000 |
$3395.00 |
| $3208.28 |  |
|
| N5K PP52 |
EA1520Z, POWER PHASE VOLT/CUR, NORMA 5000 & 4000 |
$3595.00 |
| $3397.28 |  |
|
| N5K PP54 |
EA1540Z, POWER PHASE VOLT/CUR NORMA, 5000 & 4000 |
$3295.00 |
| $3113.78 |  |
|
| Voltage |
| 8 ranges |
0.3 – 1 – 3 – 10 – 30 – 100 – 300 – 1000 V Upeak = 2 x range |
| Input impedance |
2 MOhm / 20 pF |
| CMR Common Mode Rejection |
120 dB at 100 kHz |
| Current |
| 6 ranges |
30 – 100 mA – 0.3 – 1 – 3 – 10 A Ipeak = 2 x range; max level 150 % at sine wave (limit of error as at 100 %). |
| Input impedance with integrated shunts |
| Ranges 30 mA, 100 mA |
1 Ohm |
| Ranges 0.3 A, 1 A |
0.1 Ohm |
| Ranges 3 A, 10 A |
0.01 Ohm |
| Current overload |
max. 15A continuous 30 A < 5 sec / 15 sec no load 100 A < 0.1s / 30 sec no load |
| Input for external shunt or probe |
| BNC terminal |
100 kOhm / 30pF 30 – 100 mV – 0.3 – 1 – 3- 10 V |
| Overload |
max. 20 Vrms |
| CMR common mode rejection |
120 dB at 100 kHz |
| Basic accuracy PP50 |
| Sum limit of error |
U |
I |
| Range |
0.05% |
0.05% |
| Reading |
0.05% |
0.05% |
| Voltage and current depending on the input level at 45 – 65 Hz frequency range |
| Input level |
Sum limit of error U |
Sum limit of error I |
| in % |
in % |
in % |
| 100 |
0.10 |
0.10 |
| 50 |
0.15 |
0.15 |
| 30 |
0.22 |
0.22 |
| 10 |
.55 |
.55 |
| 5 |
1.05 |
1.05 |
| 3 |
1.72 |
1.72 |
| 1 |
5.05 |
5.05 |
| |
U and I via BNC |
I direct measured |
| Bandwidth -3dB |
10 MHz |
1 MHz |
| Current measurement accuracy depending on the frequency (reading + range) |
| Frequency |
Limits of error current [ % ] |
| [Hz] |
Internal shunt |
BNC input |
| 0 |
0.10 |
-0.10 |
0.10 |
-0.10 |
| 10 |
0.10 |
-0.10 |
0.10 |
-0.10 |
| 45 |
0.10 |
-0.10 |
0.10 |
-0.10 |
| 65 |
0.10 |
-0.10 |
0.10 |
-0.10 |
| 500 |
0.10 |
-0.10 |
0.10 |
-0.10 |
| 1000 |
0.10 |
-0.10 |
0.10 |
-0.10 |
| 2000 |
0.12 |
-0.19 |
0.12 |
-0.16 |
| 5000 |
0.15 |
-0.31 |
0.13 |
-0.24 |
| 10000 |
0.18 |
-0.40 |
0.15 |
-0.30 |
| 20000 |
0.20 |
-0.49 |
0.17 |
-0.46 |
| 50000 |
0.23 |
-.61 |
0.18 |
-0.44 |
| 100000 |
0.25 |
-.70 |
0.20 |
-.50 |
| Voltage measurement accuracy depending on the frequency (reading + range) |
| Frequency in Hz |
Limits of error voltage in % |
| 0 |
0.10 |
-0.10 |
| 10 |
0.10 |
-0.10 |
| 45 |
0.10 |
-0.10 |
| 65 |
0.10 |
-0.10 |
| 500 |
0.10 |
-0.10 |
| 1000 |
0.10 |
-0.10 |
| 2000 |
0.12 |
-0.16 |
| 5000 |
0.13 |
-0.24 |
| 10000 |
0.15 |
-0.30 |
| 20000 |
0.17 |
-0.36 |
| 50000 |
0.18 |
-0.44 |
| 100000 |
0.20 |
-0.50 |
| Valid for averaged values at 23 ±5 °C ambient temperature, sine waveform and after 1 hour turn on time with measuring signal. |
| PP50 |
Between U and IBNC |
Between U and IShunt |
| Angular Error |
0.005° +0.005° / kHz |
0.025° +0.015° / kHz Aliasing filter OFF |
| Error Power |
| Frequency in Hz |
Limit of error power in % at Lamda = 1 |
| 45 |
0.16 |
-0.16 |
| 65 |
0.16 |
-0.16 |
|