Our agents are available:
9:00 AM - 6:00 PM EST
Fluke LH1060 LEM AC/DC True RMS Clamp-on Power Meter
   Search: HACKER SAFE certified sites prevent over 99.9% of hacker crime.
   

   
   




Fluke LH1060 LEM AC/DC True RMS Clamp-on Power Meter




  Specifications

LOGGING
Available data LH1050/1060: V, A, Hz + RMS value, W + VA + VAR + PF
LH1060: Waveform + RMS-value, Peak+THD+DF+CF+Ripple.
DISPLAY
Size and type 4000-count LCD+25 segment bargraph
9.5 mm/0.375-inch characters
POWER SUPPLY
Battery Type 9V Alkaline: MN1604, PP3 IEC 6LR61 or equivalent
Battery Life Typically 12 hrs.
Notes All accuracies stated at ± 23°C ± 1°C (73.4 ± 1.9 °F)
MECHANICAL DATA
Dimensions (H x W x D) 251 x 98 x 52 mm
9.88 x 3.86 x 2.05 inches
Weight 500 gm/1.1 Ibs
Jaw Capacity 1 x 50 mm/2.0-inch Ø cables or 2 x 30mm/1.2-inch Ø cables
Jaw Opening 52mm/2.2 inches
ENVIRONMENTAL DATA
Operating Temperature 0 °C to 50 °C (40°F to 122°F)
Termperature Coefficient (Current) ±0.1 % of reading per °C
±0.06 % of reading per °F
Storage Temperature -20°C to +60°C (-4°F to 140°F)
SAFETY
Note All models comply with IEC1010-1, 600 V working, installation category III, Pollution degree 2.
MAXIMUM SAFE VOLTAGES
Current measurement 600V AC RMS or DC between (bare conductors) uninsulated conductor & ground
Voltage measurement 600V AC RMS or DC between input terminals or between live terminal & local ground.



   
  Welcome | Companies | Search by Type | How To Order | Leasing | About Us  
  Tequipment.NET
205 Westwood Ave
Long Branch, NJ 07740
For our Electronic Whiteboard division visit www.touchboards.com
BBBOnline Reliability Seal. Tequipment.NET
Phone: 1-877-742-TEST (8378) / 732-222-7077
Fax: (732) 222-7088
E-mail: salesteam@Tequipment.NET