Fluke Handy Geo Earth Ground Tester for resistance measurement
   Search: HACKER SAFE certified sites prevent over 99.9% of hacker crime.
   

   
   




Fluke Handy Geo Earth Ground Tester for resistance measurement




  Specifications

General Specifications
Display 3½-digit (1999) 7 segment-liquid-crystal- Display, 16mm high, 16-division analog scale with Overload-, Underload and special symbols display, switchable display illumination
Climate class KGW as per DIN VDE 40040
Working temperature range -10° C … +50° C
Operating temp. range 0° C … +30° C
Reference temp. range 23° C (±2° C)
Storage temp. range -20° C … +60° C
Safety class Complies with safety class II
Max. voltage relative to earth IEC 1010-1 max. 600V
specified to IEC 1010 part 1 (inst. CAT II, pollution degree 2)
Safety class IP 40 as per DIN VDE 40050
Batterytype Alkaline 9 V IEC 6LR61
Indrinsic error refers to the reference temperature range and is guaranteed for 3 years
Operating measurement considers influence of operating deviation: temperature.
Position and supply voltage have no influence.
Dimensions and Weights
Dimensions 113 (W) x 54 (D) x 216 (L) mm
Weight Basic unit with accessories 990 Gram
Measurement of earthing resistance (RE 3-pole)
Measuring method Current and voltage measurement as per IEC 61557-5
Open circuit voltage <25 V AC
Short circuit current >50 mA AC
Measuring frequency 128 Hz, noise voltage suppression at 16 2/3 Hz, 50 Hz and 60 Hz >80 dB
Range Resolution Display Intrinsic error Operat.meas. deviation
0.15…20 Ω 0.01 Ω 0…19.99 Ω ±(6 % of mv + 5D) ±(8 % of mv + 5D)
200 Ω 0.1 Ω 20.0…199.9 Ω
2000 Ω 1 Ω 200…1999 Ω
RH- and RS-measuring range fix 200 kΩ. Automatic switch-over of the resolution (display range), dependent on RH, automatic test of resistances probe with warning at measuring deviations >30%.
Measurement of resistance (RE 2-pole)
Measuring method Current and voltage measurement
Open circuit voltage <25 V AC
Short circuit current >50 mA AC
Measuring frequency 128 Hz, noise voltage suppression At 16 2/3 Hz, 50 Hz and 60 Hz >80 dB
Range Resolution Display Intrinsic error Operat.meas. deviation
0.15…20 Ω 0.01 Ω 0…19.99 Ω ±(6 % of mv + 5D) ±(8 % of mv + 5D)
200 Ω 0.1 Ω 20.0…199.9 Ω
2000 Ω 1 Ω 200…1999 Ω
Measurement noise voltage (AC / DC)
Mean value rectification at AC calibrated for RMS-display for sinewave, displayed is value for AC or DC whichever is greater.
Range Resolution Display Intrinsic error
1…30 V 0.1 V 0…30.0 V ±(10 % of mv + 5D)
Umax 30 Veff
Max. overload between earth, auxiliary earth and probe 250 Veff
Input resistance approx. 1 MΩ
Common mode rejection/CMR >80 dB at 50 Hz and 60 Hz



   
  Welcome | Companies | Search by Type | How To Order | Leasing | About Us  
  Tequipment.NET
205 Westwood Ave
Long Branch, NJ 07740
For our Electronic Whiteboard division visit www.touchboards.com
BBBOnline Reliability Seal. Tequipment.NET
Phone: 1-877-742-TEST (8378) / 732-222-7077
Fax: (732) 222-7088
E-mail: salesteam@Tequipment.NET