  Specifications

General
Display 1999 digit dual LC-display with special symbols, digit height 17 mm, 30 segment analogue bar with over- and underflow and special display sign, EL backlight
Temperature ranges Working temp.: -10° C ...+50° C (+14° F ...+122° F )
Operating temp.: 0° C ...+35° C (+32° F ...+95° F )
Storage temp.: -20° C ...+60° C ( -4° F ...+140° F )
Reference temp.: +23° C ± 2° C (+73° F ± 4° F )
Temperature coefficient of A ± 0.1% of rdg / K
Temperature coefficient of V, Ω, MΩ 0.1 x operating error/K
Climatic class B2 (IEC 654-1), -5° C..+45°C, 5%...85% RH, no dew
Operating altitude max. 2000m
Protection type IP40 according to EN 60529
Safety Protection by double insulation
600V CATIII pollution degree 2
Test voltage 5550 V AC, measuring circuit to enclosure
EMC (Emission) IEC 61326-1/ EN 55011 class B
EMC (Immunity) EN 61000-4-2:8kV-class B,
EN 61000-4-3 3V/m-class A
Intrinsic error Refers to the reference temperature range and is guaranteed for 2 years.
Operating error Refers to the operating temperature range and is guaranteed for 2 years.
Quality system developed, designed and manufactured according to DIN ISO 9001
External voltage measurement inhibited for external voltage
Ux >10% of UN for MΩ and >3V for R
Max. overload 800 Veff RMS or RMS x frequency < 5x104VHz 10kAeff RMS or RMS x frequency < 4 x105AHz
Auxiliary power 4 x 1,5 V mignon cells alkali-manganese (IEC LR6)
Battery life span typical (no backlight) > 2000 measurements in MΩ. Battery life typically 100 hours continuous operation for resistance and voltage measurements, 60 hours in current
Fuse 1,25A quick acting 600V 10kA / 32x6.3mm
Jaw opening 60mm
Conductor diameter max. 58mm
Dimensions 300 x 98 x 52 mm (12 x 3.75 x 2 inches)
Weight 0.8 kg / 1.8 lbs (including batteries)
Warranty 2 years
Calibration interval 2 years recommended
MΩ - RISO Insulation Resistance
Method Voltage/current measurement as per EN 61557–2
Nominal test voltage UN = 100V, 250V, 500V, 1000V DC
Open circuit voltage U0 < 1.1 x UN
Nominal current IN ≥ 1mA DC at UN
IN &ge 2.5mA DC at 100kΩ at 250V
Short circuit current <10mA DC
R – Low Resistance Measurement
Method Voltage/current measurement as per EN 61557–4
Open circuit voltage U0 ≥ 4V
Short circuit current Ik ≥ 200mA DC up to 2Ω as per EN61557
Continuity check Buzzer activated for external resistance within 100ms
Buzzer level adjustable with LIMIT function from 0,2...50Ω.
Test lead compensation (ZERO) from 0.01...5Ω.
V – TRMS Voltage Measurement
DC Input resistance:1MΩ / 100pF
SMR Serial mode rejection approx. 60dB at 50 and 60Hz for DC (influence of AC signals to DCV-display)
CMR Common mode rejection approx. 80dB at 50 and 60Hz
Auto range setting time 1.5s
Max. voltage frequency product 5x104 VHz
Over-range up to 1000V with flashing symbol.
AC Specifications valid for AC RMS >5% of range
Measuring range Resolution Intrinsic error VAC 15Hz – 1kHz
2V 1mV ±(3% of rdg+20D)
20V 10mV ±(2% of rdg+5D)
200V 100mV ±(2% of rdg+3D)
600V 1V ±(2% of rdg+2D)
Displayed values for voltage measurements AC, DC and AC+DC+F. Crest factor 3 for values at the end of the ranges
Vpeak 1200VP
Over-range up to 800V with flashing symbol.
Continuous logging and output through RS232 interface possible.



   
  Welcome | Companies | Search by Type | How To Order | Leasing | About Us  
  Tequipment.NET
205 Westwood Ave
Long Branch, NJ 07740
For our Electronic Whiteboard division visit www.touchboards.com
BBBOnline Reliability Seal. Tequipment.NET
Phone: 1-877-742-TEST (8378) / 732-222-7077
Fax: (732) 222-7088
E-mail: salesteam@Tequipment.NET