| General Specifications |
|
DC Voltage
|
Maximum Voltage: 1000V
Accuracy: Fluke 88 V: ±(0.1%+1)
Best Resolution: Fluke 88 V: 0.01 mV
|
|
AC Voltage
|
Maximum Voltage: 1000V
Accuracy: Fluke 88 V: ±(0.5%+2)
AC Bandwidth: Fluke 88 V: 5kHz
Best Resolution: 0.01 mV
|
|
DC Current
|
Maximum Amps: 10A
Amps Accuracy: Fluke 88 V: ±(0.4%+2)
Best Resolution: Fluke 88 V: 0.001 mA
|
|
AC Current
|
Maximum Amps: 10A
Amps Accuracy: Fluke 88 V: ±(1.2%+2)
Best Resolution: 0.001 mA
|
|
Resistance
|
Maximum Resistance: 50 MΩ
Accuracy: Fluke 88 V: ±(0.4%+1)
Best Resolution: 0.1Ω
|
|
Capacitance
|
Maximum Capacitance: 9,999 µF
Accuracy: ±(1%+2)
Best Resolution: 0.01 nF
|
|
Frequency
|
Maximum Frequency: 200 KHz
Accuracy: ±(0.005%+1)
Best Resolution: 0.01 Hz
|
|
Duty Cycle
|
Maximum Duty Cycle: 99.9 %
Accuracy: within 2% per KHz +0.1%
Best Resolution: 0.1 %
|
|
Temperature Measurement
|
-200.0°C - 1090°C
-328.0°F - 1994.0°F, 1.0% excluding probe
|
|
80 BK Temperature Probe
|
-40 °C - 260 °C
-40 °F - 500 °F, 2.2 °C or 2% whichever is greater
|
|
Conductance
|
Maximum Conductance: 60.00 nS
Accuracy: ±(1.0%+10)
Maximum Resolution: 0.01 nS
|
|
Operating Range
|
Operating Temperature: -20 °C - 55 °C
Storage Temperature: -40 °C - 60 °C
|
|
Physical
|
5.2 cm x 9.8cm x 20.1 cm (2.06” x 3.86” x 7.93”)
624 g (22 oz.)
|
|
Included Accessories
|
88V, TL224 silicone test leads, AC285 long reach alligator clips, TP220 test probes, RPM 80 inductive RPM pick-up, magnet and strap, 80BK temperature probe, two automotive backprobe pins, insulation piercing probe, C800 durable carrying case, holster, 9V battery (installed), Getting Started Manual, and CD with detailed manual.
|