company logo Fluke 87 Series III Digital Multimeter
     Search: HACKER SAFE certified sites prevent over 99.9% of hacker crime.  
 

 
 




Fluke 87 Series III Digital Multimeter





General Specifications
DCV Maximum Voltage: 1000V

Accuracy: Fluke 83 III: ±(0.1%+1)
Fluke 85 III: ±(0.08%+1)
Fluke 87 III: ±(0.05%+1)
Fluke 87/E: ±(0.05%+1)

Maximum Resolution: 0.1 mV

ACV Maximum Voltage: 1000V

Accuracy:
Fluke 83 III: ±(0.5%+2)
Fluke 85 III: ±(0.7%+2)
Fluke 87 III: ±(0.7%+2)
Fluke 87/E: ±(0.7%+2)

Maximum Resolution: 0.1 mV

DC Current Maximum Amps: 10A

Amps Accuracy:
Fluke 83 III: ±(0.4%+2)
Fluke 85 III: ±(0.2%+2)
Fluke 87 III: ±(0.2%+2)
Fluke 87/E: ±(0.2%+2)

Maximum Resolution:
Fluke 83 III: 0.01 mA
Fluke 85 III: 0.1 µA
Fluke 87 III: 0.1 µA
Fluke 87/E: 0.1 µA

AC Current Maximum Amps: 10A

Amps Accuracy:
Fluke 83 III: ±(1.2%+2)
Fluke 85 III: ±(1.0%+2)
Fluke 87 III: ±(1.0%+2)
Fluke 87/E: ±(1.0%+2)

Maximum Resolution: 0.1 µA

Resistance Max Resistance: 40 MW

Accuracy:
Fluke 83 III: ±(0.4%+1)
Fluke 85 III: ±(0.2%+1)
Fluke 87 III: ±(0.2%+1)
Fluke 87/E: ±(0.2%+1)

Maximum Resolution: 0.1W

Capacitance 1 nF-5µF
Frequency 0.5 Hz to 200 kHz


User's Manual & Service Information
Getting Started Getting Started (.pdf, 121 KB)
80 Series III User's Manual User's Manual (.pdf, 629 KB)
Service Information Service Information (.pdf, 508 KB)




 

Welcome | Companies | Search by Type | How To Order | Leasing | About Us | Careers
  Tequipment.NET
205 Westwood Ave
Long Branch, NJ 07740
BBBOnline Reliability Seal, Click for confirmation page. Tequipment.NET
Phone: 1-877-742-TEST (8378) / 732-222-7077
Fax: (732) 222-7088
E-mail: salesteam@Tequipment.NET
 




Fluke Educational Grant Program

Fluke Stock Guarantee

Fluke Multimeter Free Case

Fluke 110% Price Match Guarantee

Quote Request

We Take POs, How To Order

Free Shipping on Fluke










Live chat by BoldChat
Need help? We have a staff
of more than 30 people to help you.
Let us show you why over 100,000
customers choose Tequipment.NET