company logo Fluke 8062A Digital Multimeter
     Search: HACKER SAFE certified sites prevent over 99.9% of hacker crime.  
 

 
 




Fluke 8062A Digital Multimeter




Technical Specifications
VDC Range and Resolution: 200.00 mV, 2.0000V, 20.000V, 200.00V, 1000.0V
8060A: 200.00 mV, 2.0000V, 20.000V, 200.00V, 1000.0V
8062A: ±(0.05%+2)
VAC (True-RMS, AC Coupled) Range and Resolution: 200.00 mV, 2.0000V, 20.000V, 200.00V, 750.0V
8060A: ±(0.2%+10)
8062A: ±(0.5%+10)
dBm, 600Ohms reference Range and Resolution: -50.00 - +60.00 dBm
8060A: ±(0.15 dB)
8062A: NA
ADC Range and Resolution: 200.00 µA, 2.0000 mA, 20.000 mA, 200.00 mA, 2000.0 mA
8060A: ±(0.2%+2)
8062A: ±(0.3%+2)
AAC (True-RMS) Range and Resolution: 200.00 µA, 2.0000 mA, 20.000 mA, 200.00 mA, 2000.0 mA
8060A: ±(0.75%+10)
8062A: ±(0.75%+10)
Resistance Range and Resolution: 200.00Ohms, 2.0000 kOhms, 20.000 kOhms, 200.00 kOhms, 300.0 MOhms
8060A: ±(0.07%+2)
8062A: ±(0.1%+2)
Frequency Range and Resolution: 200.00 Hz, 2.0000 kHz, 20.000 kHz, 200.00 kHz
8060A: ±(0.05%+1)
8062A: NA
Conductance Range and Resolution: 2000.0 nS (equivalent to 500 kOhms)
8060A: ±(0.5%+20)
8062A: NA


General Specifications
Battery Life 170 hours typical (9V alkaline)
Weight 0.41 kg (0.90 lb)
Size 180 mm L x 86 mm W x 45 mm D (7.1" L x 3.4" W x 1.8" D)
One Year Warranty One year guaranteed calibration






 

Welcome | Companies | Search by Type | How To Order | Leasing | About Us | Careers
  Tequipment.NET
205 Westwood Ave
Long Branch, NJ 07740
BBBOnline Reliability Seal, Click for confirmation page. Tequipment.NET
Phone: 1-877-571-7901 / 732-222-7077
Fax: (732) 222-7088
E-mail: salesteam@Tequipment.NET
 




Fluke Educational Grant Program

Fluke Stock Guarantee

Fluke Multimeter Free Case

Fluke 110% Price Match Guarantee

Quote Request

We Take POs, How To Order

Free Shipping on Fluke










Live chat by BoldChat
Need help? We have a staff
of more than 30 people to help you.
Let us show you why over 100,000
customers choose Tequipment.NET