Fluke 8060A Digital Multimeter
| Technical Specifications |
| VDC |
Range and Resolution: 200.00 mV, 2.0000V, 20.000V, 200.00V, 1000.0V
8060A: 200.00 mV, 2.0000V, 20.000V, 200.00V, 1000.0V
8062A: ±(0.05%+2) |
| VAC (True-RMS, AC Coupled) |
Range and Resolution: 200.00 mV, 2.0000V, 20.000V, 200.00V, 750.0V
8060A: ±(0.2%+10)
8062A: ±(0.5%+10) |
| dBm, 600Ohms reference |
Range and Resolution: -50.00 - +60.00 dBm
8060A: ±(0.15 dB)
8062A: NA |
| ADC |
Range and Resolution: 200.00 µA, 2.0000 mA, 20.000 mA, 200.00 mA, 2000.0 mA
8060A: ±(0.2%+2)
8062A: ±(0.3%+2) |
| AAC (True-RMS) |
Range and Resolution: 200.00 µA, 2.0000 mA, 20.000 mA, 200.00 mA, 2000.0 mA
8060A: ±(0.75%+10)
8062A: ±(0.75%+10) |
| Resistance |
Range and Resolution: 200.00Ohms, 2.0000 kOhms, 20.000 kOhms, 200.00 kOhms, 300.0 MOhms
8060A: ±(0.07%+2)
8062A: ±(0.1%+2) |
| Frequency |
Range and Resolution: 200.00 Hz, 2.0000 kHz, 20.000 kHz, 200.00 kHz
8060A: ±(0.05%+1)
8062A: NA |
| Conductance |
Range and Resolution: 2000.0 nS (equivalent to 500 kOhms)
8060A: ±(0.5%+20)
8062A: NA |
| General Specifications |
| Battery Life |
170 hours typical (9V alkaline) |
| Weight |
0.41 kg (0.90 lb) |
| Size |
180 mm L x 86 mm W x 45 mm D (7.1" L x 3.4" W x 1.8" D) |
| One Year Warranty |
One year guaranteed calibration |
|