Technical Specifications
VDC Range and Resolution: 320.0 mV, 3.200V, 32.00V, 320.0V, 1000V
Best Accuracy: ±(0.1%+1)
VAC Range and Resolution:320.0 mV, 3.200V, 32.00V, 320.0V, 1000V
Best Accuracy: ±(0.5%+3)
ADC Range and Resolution: 320.0 µA, 3200 µA, 32.00 mA, 320.0 mA, 10.00A
Best Accuracy: ±(0.75%+2)
AAC Range and Resolution: 320.0 µA, 3200 µA, 32.00 mA, 320.0 mA, 10.00A
Best Accuracy: ±(1.5%+2)
Resistance Range and Resolution:
320.0 W, 3.200 kW, 32.00 kW, 320.0 kW, 3.200 MW, 32.00 MW
Best Accuracy: ±(0.2%+1)
Conductance Range and Resolution: 32.00 nS
Best Accuracy: ±(2%+10)
Battery Life Typically over 1000 hours (alkaline)
Size 203 mm L x 95 mm W x 56 mm D (8" L x 3.75" W x 2.2" D)
Weight 0.75 kg (1.6 lb)
Lifetime Limited Warranty One year calibration interval


User's Manual & Other Documentation
Model 27 - User's Manual User's Manual (.pdf, 221 KB)
Model 27 - Service Manual Service Manual (.pdf, 3.51 MB)
Model 27 - Service Manual Supplement Service Manual Supplement (.pdf, 72.4 KB)






 

Welcome | Companies | Search by Type | How To Order | Leasing | About Us | Careers
  Tequipment.NET
205 Westwood Ave
Long Branch, NJ 07740
BBBOnline Reliability Seal, Click for confirmation page. Tequipment.NET
Phone: 1-877-571-7901 / 732-222-7077
Fax: (732) 222-7088
E-mail: salesteam@Tequipment.NET
 




Fluke Educational Grant Program

Fluke Stock Guarantee

Fluke Multimeter Free Case

Fluke 110% Price Match Guarantee

Quote Request

We Take POs, How To Order

Free Shipping on Fluke










Live chat by BoldChat
Need help? We have a staff
of more than 30 people to help you.
Let us show you why over 100,000
customers choose Tequipment.NET