Features

  • Accurate temperature measurement from -40 to 750°F (-40 to 400°C) (500°F with supplied probe)
  • Confidently test flame sensor circuits with microamp measurement down to 0.1 microamps
  • Capacitance up to 10,000 microfarads
  • Min/Max recording with relative time stamp records the highest and lowest voltage readings during a 100-hour period
  • Auto-ranging
  • High resistance ranges to 40 megohms
  • Millivolt range for compatibility with other accessories V-Check™ mode is designed for safety.
  • When measuring ohms, continuity, or diode test modes, the meter automatically switches to measuring ac or dc volts if more than 4.5V is present
  • Continuity Capture™ locates intermittent opens as brief as 250 microseconds and identifies them in a symbolic display as short-to-open or open-to-short
  • Sleep mode preserves battery life
  • 4000 count digital display
Loading Prices
List Price: $159.95
+ Free shipping over $99
Loading Callouts
Request a Quote
Loading Series Compare

Product Information

Multimeter


Thermometer

The Fluke 16 measures temperature quickly and accurately. Standard equipment includes an 80BK integrated DMM temperature probe.

Flame rod circuit tester

A microamp function is included for flame sensor measurements down to 0.1 microamps.

with Capacitance

Use the Fluke to test motor start and run capacitors up to 10,000 microfarads. Rely on the Fluke 16 to make your everyday measurements - up to 600 volts ac or dc, 40 megohms, diode test and exceptionally fast continuity.

Specifications

DC Volts Specifications
Range 4000 mV * Resolution: 1 mV
Accuracy: 0.9% + 2
Range 4.000 V Resolution: 0.001 V
Accuracy: 0.9% + 2
Range 40.00 V Resolution: 0.01 V
Accuracy: 0.9% + 1
Range 400.0 V Resolution: 0.1 V
Accuracy: 0.9% + 1
Range 600 V Resolution: 1 V
Accuracy: 0.9% + 1
*The 4000 mV range can only be entered in manual range mode.
Use the 4000 mV range with accessories.



AC Volts Specifications
Range 4000 mV * Resolution: 1 mV
Accuracy: 1.9% + 3
Range 4.000 V Resolution: 0.001 V
Accuracy: 1.9% + 3
Range 40.00 V Resolution: 0.01 V
Accuracy: 1.9% + 3
Range 400.0 V Resolution: 0.1 V
Accuracy: 1.9% + 3
Range 600 V Resolution: 1 V
Accuracy: 1.9% + 3
*The 4000 mV range can only be entered in manual range mode.
Use the 4000 mV range with accessories.



Current (AC/DC) Specifications
Range 200 µA Resolution: 0.1 µA
Accuracy: 0.5% + 2


Ohms Specifications
Range 400.0 W Resolution: 0.1 W
Accuracy: 0.9% + 2
Range 4.000 KW Resolution: 0.001 KW
Accuracy: 0.9 % + 1
Range 40.00 KW Resolution: 0.01 KW
Accuracy: 0.9% + 1
Range 400.0 KW Resolution: 0.1 KW
Accuracy: 0.9% +1
Range 4.000 MW Resolution: 0.001 MW
Accuracy: 0.9% +1
Range 40.00 MW Resolution: 0.01 MW
Accuracy: 1.5% +3


Capacitance Specifications *
Range 1.000 µF Resolution: 0.001 µF
Accuracy: 1.9% + 2
Range 10.00 µF Resolution: 0.01 µF
Accuracy: 1.9% + 2
Range 100.0 µF Resolution: 0.1 µF
Accuracy: 1.9% + 2
Range 1000 µF Resolution: 1.0 µF
Accuracy: 1.9% + 2
Range 10,000 µF Resolution: 10.0 µF
Accuracy: 10% + 90 typical
*The accuracy specification is for capacitors that have negligible dielectric absorption. Capacitance measured with rc charge technique that evaluates C = Q/V. Capacitors with non-negligible dielectric absorption can be measured but measurement values may be in error.


Temperature Specifications *
Range 15 to 750 °F Resolution: 0.1 °F
Accuracy: 1% + 1.5 °F typical
Range -40 to 15 °F Resolution: 0.1 °F
Accuracy: 5% + 2.7 °F
Range -10 to 400 °C Resolution: 0.1 °C
Accuracy: 1% + 0.8 °C typical
Range -40 to 10 °C Resolution: 0.1 °C
Accuracy: 5% + 1.5 °C
*Temperature accuracy specifications do not include the error of the thermocouple.


Safety
600V ac/dc Maximum voltage between any terminal and earth ground. Conforms to the requirements of IEC-1010-1, 1990-09 and ANSI/ISA-S82.01-94 for use in Overvoltage Category III locations. Make ac or dc voltage measurements on electrical distribution systems to 600V where transients do not exceed 6 kV and only on circuits limited to 14 kVA if the circuit voltage rating is above 250V.
Certification agencies (approvals/listings pending) UL Per standard UL 3111
CSA Per standard CSA/CAN C22.2 No.1010.1-92
TsV Per standard EN61010 Part 1-1993
Drop test ANSI/ISA-S82.01-94 and EN61010 Part1-1993. 10 ft. drop to hardwood on concrete


General Specifications
Size (HxWxL) 1.12" x 2.95" x 6.55", (2.8 cm x 7.5 cm x 16.6 cm)
Battery life 650 hours with Alkaline
Weight 12 oz (340g)
Warranty Three years


 

User's Manual & Service Information
Model 16 Instruction Sheet Instruction Sheet (.pdf, 196 KB)
Model 16 Calibration Information Calibration Information (.pdf, 229 KB)
Model 16 Calibration Information Supplement Calibration Information Supplement (.pdf, 6 KB)

Reviews

16 Customer Reviews

0 Reviews
5 stars
 (0)
4 stars
 (0)
3 stars
 (0)
2 stars
 (0)
1 star
 (0)
 
 
 
 
 
Average Customer Review
         
0 reviews
0 customer reviews
Share your thoughts with other customers
Create your own review
 
Most Helpful First | Newest First      Prev Page
 
Prev Page
 

Fluke Price List

X


secured website

Interworld Highway, LLC dba TEquipment.NET

205 Westwood Avenue. Long Branch, NJ 07740

Privacy Policy | Terms and Conditions | Site Map

Copyright© 2016 Interworld Highway, LLC

secured website
We Price Match!

Give our sales team a call at 877.571.7901 (Toll Free) or 732.222.7077 (International) and we'll match any competitor's price.

X