Fluke 36 Clamp Meter
| Technical Specifications |
| DC Current |
Range: 1000A, 200A
Resolution: 1A, .1A
Accuracy: 0-600A: ±(1.9%+4), 600-1000A:±(3%+3), 0-200A: ±(1.9%+7)
|
| DC Volts |
Range: 600V/200V
Resolution: 1V/.1V
Accuracy: ±(1.0%+3)
|
| AC Current (45-400Hz) |
Range: 600A/200A
Resolution: 1V/.1V
Accuracy: ±(2%+3)/±(2%+5)
Crest Factor: Between 2 and 3 add 2% of reading
|
| AC Volts (45-400Hz) |
Range: 600V/200V
Resolution: 1V/.1V
Accuracy: ±(1.5%+3)
Crest Factor: <=3 (pk voltage ±933V)
|
| Ohms |
Range: 200 Ohms
Resolution: 0.1 Ohms
Accuracy: +(1.2%+5)
Crest Factor: NA
|
| General Specifications |
| RF field |
RF field = <=1V/m, total accuracy = specified accuracy
RF field = 3V/m, total accuracy = specified accuracy + 4% of range
|
| Operating temperature |
-10°C to 50°C (14°F to 122°F) |
| Battery life |
60 hours continuous, alkaline, sleep mode |
| Size |
248.9 mm L x 95.2 mm W x 45 mm D (9.8 in L x 3.75 in W x 1.75 in D) |
| Weight |
0.45 kg (1 lb.) |
| Warranty |
One Year Warranty |
|
|
|
|